U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
11/02/2000 - 11/03/2000
** EVENT NUMBERS **
37479 37482 37483 37484
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 37479 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: SCHERING-PLOUGH |NOTIFICATION DATE: 11/01/2000|
|LICENSEE: SCHERING CORPORATION |NOTIFICATION TIME: 16:08[EST]|
| CITY: KENILWORTH REGION: 1 |EVENT DATE: 11/01/2000|
| COUNTY: STATE: NJ |EVENT TIME: [EST]|
|LICENSE#: 29-00244-02 AGREEMENT: N |LAST UPDATE DATE: 11/02/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |JACK MCFADDEN R1 |
| |JOHN HICKEY NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JAEGER | |
| HQ OPS OFFICER: BOB STRANSKY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| MISSING SHIPMENT OF I-125 |
| |
| The licensee reported that a shipment of I-125 (10 vials, 100 µCi each) that |
| was scheduled to arrive via FedEx on 10/31/00 cannot be located. When the |
| package was not checked in to the RSO on 10/31/00, the licensee contacted |
| the local FedEx office and attempted to locate the package. According to |
| FedEx, the package was delivered on 10/26/00. The licensee stated that |
| incoming FedEx packages are not invoiced and signed for individually; |
| instead, a master list of packages is presented with the delivery (the |
| packages are scanned when they are loaded onto the truck). The package has |
| not been reported as misdelivered by any other FedEx customers. |
| |
| * * * RETRACTED AT 1515 EST ON 11/2/00 BY FRED JAEGER TO FANGIE JONES * * * |
| |
| The licensee is retracting the event notification because they received the |
| shipment today from FedEx fully intact and complete, just late. They |
| discussed this with NRC Region 1 (Eric Reber) who informed John Kinneman. |
| |
| The R1DO (Pete Eselgroth) and NMSS (Brian Smith). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37482 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 11/02/2000|
| UNIT: [1] [2] [] STATE: FL |NOTIFICATION TIME: 13:33[EST]|
| RXTYPE: [1] CE,[2] CE |EVENT DATE: 11/02/2000|
+------------------------------------------------+EVENT TIME: 13:20[EST]|
| NRC NOTIFIED BY: JIM BREEN |LAST UPDATE DATE: 11/02/2000|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |BRIAN BONSER R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE TO A DEAD TURTLE FOUND IN THE PLANT INTAKE |
| |
| The licensee made a call to the U. S. Fish and Wildlife Agency and the |
| Florida Fish and Wildlife Conservation Commission to notify them of a dead |
| loggerhead turtle (about 40 pounds) found in the plant intake. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37483 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CLINTON REGION: 3 |NOTIFICATION DATE: 11/02/2000|
| UNIT: [1] [] [] STATE: IL |NOTIFICATION TIME: 16:08[EST]|
| RXTYPE: [1] GE-6 |EVENT DATE: 11/02/2000|
+------------------------------------------------+EVENT TIME: 12:00[CST]|
| NRC NOTIFIED BY: JIM SCHOTTEL |LAST UPDATE DATE: 11/02/2000|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |DAVID HILLS R3 |
|10 CFR SECTION: | |
|ADAS 50.72(b)(2)(i) DEG/UNANALYZED COND | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| INSTRUMENT AIR CONTAINMENT PENETRATION FAILED LEAKAGE TESTING |
| |
| "Currently Clinton is in RF-7. During performance of LLRTs of the Instrument |
| Air penetration (1 MC-057), AOV 1IA005 (outboard isolation valve) would not |
| close upon demand. The solenoid was later found to be sticking. Therefore, |
| this valve was an as-found failure. Subsequently, the testing of the inboard |
| containment isolation valve in this same penetration (1IA006), showed a |
| leakage of 27,500 sccm at the air regulator assembly. When other known |
| leakage pathways are combined with this leakage, the secondary bypass |
| leakage criteria of 0.08 La (28,883 sccm) is violated (Tech Spec Section |
| 3.6.1.3 SR 3.6.1.3.9), |
| |
| "These valves were repaired, and subsequently successfully passed their |
| LLRTs. |
| |
| "Further analysis of these failures will be performed during the |
| investigation of Condition Report 2-00-10-273." |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 37484 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: US ARMY |NOTIFICATION DATE: 11/02/2000|
|LICENSEE: US ARMY |NOTIFICATION TIME: 16:31[EST]|
| CITY: ROCK ISLAND REGION: 3 |EVENT DATE: 11/02/2000|
| COUNTY: STATE: IL |EVENT TIME: [CST]|
|LICENSE#: 12-00722-06 AGREEMENT: Y |LAST UPDATE DATE: 11/02/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |DAVID HILLS R3 |
| |C.W. (BILL) REAMER NMSS |
+------------------------------------------------+PHIL HARRELL R4 |
| NRC NOTIFIED BY: JEFF HAVENNER | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB2 20.2201(a)(1)(ii) LOST/STOLEN LNM>10X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| STOLEN M43A1 CHEMICAL AGENT DETECTOR |
| |
| Council Bluff, Iowa Reserve Unit reported today, to Rock Island, that one |
| M43A1 chemical agent detector, containing 250 µCi (microcurie) of Am-241, |
| was stolen on 6/1/2000. The detector was reported stolen in Omaha, Nebraska |
| to the Omaha police. The device has not been recovered. |
+------------------------------------------------------------------------------+