Event Notification Report for September 7, 2005
U.S. Nuclear Regulatory Commission Operations Center
Event Reports For 09/05/2005 - 09/07/2005
** EVENT NUMBERS **
|
Power Reactor |
Event Number: 41954 |
Facility: WATERFORD
Region: 4 State: LA
Unit: [3] [ ] [ ]
RX Type: [3] CE
NRC Notified By: KENNY CAMBREY
HQ OPS Officer: JEFF ROTTON
|
Notification Date: 08/27/2005
Notification Time: 23:22 [ET]
Event Date: 08/27/2005
Event Time: 22:04 [CDT]
Last Update Date: 09/07/2005
|
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
|
Person (Organization):
WILLIAM JONES (R4)
PAO-TSIN KUO (NRR)
MEL LEACH (IRD)
AKERS (DHS)
CASTO (FEMA)
|
Unit |
SCRAM Code |
RX CRIT |
Initial PWR |
Initial RX Mode |
Current PWR |
Current RX Mode |
3 |
N |
Y |
100 |
Power Operation |
100 |
Power Operation |
Event Text
UNUSUAL EVENT DECLARED DUE TO HURRICANE WARNING
At 2204 CDT, an Unusual Event was declared due to a Hurricane warning in St Charles Parish, LA. The licensee does not have any Limiting Conditions for Operation on safety related equipment. No electrical grid disturbances currently exist.
The licensee will be notifying the NRC Resident Inspector. The licensee notified the State and Local government agencies.
* * * UPDATE FROM J. PIERCE TO M. RIPLEY 1144 EDT 08/28/05 * * *
"Waterford 3 will commence a plant shutdown to Mode 4 on August 28, 2005 at 1100 CDT. The goal is to be approximately 325 deg F reactor coolant system temperature with both trains of Shutdown Cooling in service [expected at approximately 0100 CDT 08/29/05] . This is approximately 2 hours before hurricane force winds are expected on site."
Notified R4DO (Jones), NRR EO (Kuo), IRD Mgr. (Wilson), DHS (York), and FEMA (Canupp).
* * * UPDATE FROM J. PIERCE TO J. ROTTON 1131 EDT 08/29/05 * * *
As a result of Hurricane Katrina, all offsite power was lost at 0800 CDT. The emergency diesel generators successfully started and loaded.
Notified R4DO (R. Bywater), NSIR (Leach, Wilson), NRR EO (Kuo, Jung), FEMA (Kuzia), DHS (Stransky).
* * * UPDATE FROM LICENSEE (LEWIS) TO NRC (HUFFMAN) AT 2302 EDT ON 8/29/05 * * *
The Hurricane warning for St Charles Parish, LA, has been discontinued by the National Weather Service. Initiating condition, D UE-5, is no longer applicable. Waterford 3 remains in an Unusual Event for initiating condition C UE-1, loss of all offsite power. An agreement to relax 60 minute notification updates to State and local authorities remains in effect.
The licensee has notified State and local authorities as well as the NRC Resident Inspector.
Offsite power is available to the licensee switchyard. However, the voltage is too high for plant specification and the licensee remains disconnected from offsite power and on the emergency diesel generators.
* * * UPDATE FROM LICENSEE (LEWIS) TO NRC (KNOKE) AT 0001 EDT ON 8/31/05 * * *
Waterford 3 remains in an Unusual Event for initiating condition C UE-1, loss of all offsite power. An agreement to relax 60 minute notification updates to State and local authorities remains in effect. The communications system for Public Automatic Branch Exchange (PABX) is working internally, but not externally. Other areas where communications are lost are Emergency Operations Facility (EOF), Operations hotline, Reactor Auxiliary Building (RAB), and the Emergency Notification System (ENS). Waterford has use of an industrial hotline to a circuit in the Parish of St Charles, however, this is very limited in its capability. The Civil Defense communication system is still inoperable.
* * * UPDATE AT 1903 ON 9/6/05 FROM WAIG TO GOULD * * *
NRC exited monitoring mode at 1800 CDT on 9/6/05.
Notified R4 IRC (Waig), R4DO (Powers), IRD (Leach), DHS (Cartlidge), FEMA (Kuzia). |
Power Reactor |
Event Number: 41970 |
Facility: ARKANSAS NUCLEAR
Region: 4 State: AR
Unit: [1] [2] [ ]
RX Type: [1] B&W-L-LP,[2] CE
NRC Notified By: JAMES CRABILL
HQ OPS Officer: ARLON COSTA
|
Notification Date: 09/06/2005
Notification Time: 21:45 [ET]
Event Date: 09/06/2005
Event Time: 14:05 [CDT]
Last Update Date: 09/06/2005
|
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
|
Person (Organization):
DALE POWERS (R4)
|
Unit |
SCRAM Code |
RX CRIT |
Initial PWR |
Initial RX Mode |
Current PWR |
Current RX Mode |
1 |
N |
Y |
100 |
Power Operation |
100 |
Power Operation |
2 |
N |
Y |
100 |
Power Operation |
100 |
Power Operation |
Event Text
QUALITY ASSURANCE FITNESS FOR DUTY BLIND SAMPLES TESTING
"This event was determined to be reportable per 10 CFR26 Appendix A Section 2.8(e)(4): The licensee shall investigate any unsatisfactory (blind) performance testing result. A record shall be made of the investigation findings and the corrective actions taken by the laboratory.
"Event Description: Two known positive Fitness for Duty QA blind samples (both had the same lot number) were sent to the drug testing laboratory and both results came back negative."
The licensee will notify the NRC Resident Inspector. |
|