What is a laser?

Laser stands for Light Amplification by the Stimulated Emission of Radiation. One basic type of laser consists of a sealed tube, containing a pair of mirrors, and a laser medium that is excited by some form of energy to produce visible light, or invisible ultraviolet or infrared radiation.

There are many different types of lasers and each uses a different type of laser medium. Common laser media include gases such as argon or a helium and neon mixture, solid crystals such as ruby, and liquid dyes or chemicals. When energy is applied to the laser medium, it becomes excited and releases energy as particles of light (photons).

A pair of mirrors at either end of the sealed tube either reflects or transmits the light (see illustration below) in the form of a concentrated stream called a laser beam. Each laser medium produces a beam of a unique wavelength and color.

Laser

Graphic of a laser which shows the sealed tube with laser medium, mirror that both reflects and transmits, the laser beam and a mirror that titally reflects

 

What are lasers used for?

Lasers are used for a variety of purposes including pointing out objects during a presentation, aligning materials at construction sites and in the home, and by doctors for cosmetic and surgical procedures. Many items you encounter on a daily basis use lasers, including CD and DVD players; bar code scanners; dental drills; laser-guided tools, such as levels; and laser pointers.

Why are lasers uniquely hazardous?

Two characteristics of laser light contribute to the hazard:

  • Laser light can be emitted in a tight beam that does not grow in size at a distance from the laser. This means that the same degree of hazard can be present both close to and far from the laser.
  • The eye can focus a laser beam to a very small, intense spot on its retina, which can result in a burn or blind spot.

What do you mean by laser “radiation?” Does it go through the body or cause cancer?

Some lasers emit radiation in the form of light. Others emit radiation that is invisible to the eye, such as ultraviolet or infrared radiation. In general, laser radiation is not in itself harmful, and behaves much like ordinary light in its interaction with the body. Laser radiation should not be confused with radio waves, microwaves, or the ionizing x-rays or radiation from radioactive substances such as radium.

 Are all lasers legal for consumer use?

No. Some lasers are strictly for use by medical, industrial, or entertainment professionals and should only be used by a person with appropriate training and licenses.

The FDA requires labels on most laser products that contain a warning about the laser radiation and other hazards, and a statement certifying that the laser complies with FDA safety regulations. The label must also state the power output and the hazard class of the product. Consumer laser products are generally in classes I, II, and IIIa, while lasers for professional use may be in classes IIIb and IV.

What do the different classifications of lasers mean?

The FDA recognizes four major hazard classes (I to IV), including two subclasses (IIIa and IIIb), of lasers--ranging from those that pose no known hazard to those that pose serious danger if used improperly. The higher the class, the more powerful the laser is.

Class

Laser Hazard

Product Examples

I

Laser usually contained within the product and considered non- hazardous.

Laser printers
CD players
DVD players

II

IIa

Visible laser or laser system that cannot cause eye damage unless viewed directly for an extended period of time, or with magnifiers, binoculars, or telescopes.

Bar code scanners

IIIa

 

 

 

 

 

IIIb

Laser that normally does not present a risk of injury if viewed momentarily with an unaided eye, but may present a greater risk if viewed using magnifiers, binoculars, or telescopes.

 

 

Laser can cause eye damage if viewed directly

Laser pointers

 

 

 

 

 

Laser light shows
Industrial lasers
Research lasers

IV

Laser may cause severe eye injury with short duration exposure to the direct or reflected beam. May also cause severe skin damage and present a fire hazard.

Laser light shows
Industrial lasers
Research lasers

What are laser pointers?

Laser pointers are tools used for pointing out objects or locations, and are defined as "surveying, leveling, and alignment laser products" in an FDA regulation. They are commonly used during lectures and astronomy presentations, and laser pointers incorporated into spirit levels and hand tools are also very popular. In recent years laser pointers have become readily available, and are commonly sold in hardware, pet, hobby, and office supply stores.

 Are laser pointers safe?

When used properly lasers pointers are safe. Laser pointers are misused when they are directed at the eyes or treated as toys. The light energy from a laser pointer aimed into the eye can be more damaging than looking directly into the sun. And the startling effect of a bright beam of light can cause serious accidents when aimed at someone driving a car or operating other machinery.

The FDA is concerned about the increased availability of a variety of laser products that may be illegal or unsafe. Green laser pointers have the agency particularly concerned. While there are legitimate uses for green pointers, they may be altered to become more powerful and unsafe if not used responsibly.

What is the proper use of a laser pointer?

Remember, laser pointers are not toys and they should only be used by an adult, or with adult supervision.

  • Never aim or shine a laser pointer at anyone.
  • Only activate the laser pointer when you are using it to point at a nearby object.
  • Do not buy laser pointers for your children. Lasers are not toys.
  • Before purchasing a laser pointer, make sure it has the following information on the label:
    • a statement that it complies with Chapter 21 CFR (the Code of Federal Regulations)
    • the manufacturer or distributor's name and the date of manufacture
    • a warning to avoid exposure to laser radiation
    • the class designation, ranging from Class I to IIIa. Class IIIb and IV products should be used only by individuals with proper training and in applications where there is a legitimate need for these high-powered products.

What is FDA’s role in regulating lasers?

The FDA regulates both medical and non-medical lasers. The FDA may inspect manufacturers of laser products and require the recall of products that don't comply with federal standards or that have radiation safety defects. The agency also may test laser products and inspect displays of laser light shows to ensure the public is protected. Producers of laser light shows are required to tell the FDA where they are planning a show so that the agency can inspect it if possible and take action if required.

FDA is currently working to identify manufacturers of overpowered green laser pointers and other illegal lasers, and is taking action to prevent these unsafe products from being sold in the United States.

Where can I get more information?

If you have questions about a laser product you are considering purchasing or offering for sale on the Internet, contact the FDA's Center for Devices and Radiological Health at (240) 276-0326.

To report Web sites that you suspect are illegally selling laser products, follow the instructions at www.fda.gov/oc/buyonline/buyonlineform.htm

Updated January 26, 2006

horizonal rule

CDRH Home Page | CDRH A-Z Index | Contact CDRH | Accessibility | Disclaimer
FDA Home Page | Search FDA Site | FDA A-Z Index | Contact FDA | HHS Home Page