Home | About CDC | Press Room | A-Z Index | Contact Us
CDC Centers for Disease Control and Prevention Home Page
CDC en Español
 

Inspection Detail Report

  Basic Search |  Advanced Search |  Ship Scored 100 |  Green Sheet
 
Cruise Ship: Norwegian Wind Cruise line: Norwegian Cruise Lines Inspection Date: 01/31/2007 Score: 96
 
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.



 
    Cruise Ship's Corrective Action Statement

Item No.: 06
Site: Potable Water-
Violation: In addition to the production chart, the vessel was keeping circular charts. Per the engineer, these charts were for production and bunkering. A review of the logs noted that none were initialed, some were not dated, and numerous charts had double recordings for both pH and free chlorine residual. There was no indication that the analyzer-chart recorder was calibrated. Additionally, many of the charts were out of order so it was not possible to identify the dates for the charts that were not dated.
Recommendation: Ensure that halogen analyzer-chart recorder charts are changed, initialed, and dated daily and contain notations of any unusual water events in the potable water system.
Item No.: 06
Site: Potable Water-
Violation: In addition to the production chart, the vessel was keeping circular charts. Per the engineer, these charts were for production and bunkering. A review of the logs noted that none were initialed, some were not dated, and numerous charts had double recordings for both pH and free chlorine residual. There was no indication that the analyzer-chart recorder was calibrated. Additionally, many of the charts were out of order so it was not possible to identify the dates for the charts that were not dated.
Recommendation: Ensure that halogen analyzer-chart recorders used in lieu of manual tests and logs are calibrated at the beginning of bunkering or production, and the calibration is recorded on the chart or in a log book.
Item No.: 06
Site: Potable Water-
Violation: The log for bacteriological sampling of the bunkered water and the water on the vessel did not consistently provide a record of the E. coli testing results. In a few cases, only a record of a positive test for coliforms was recorded with no indication of the result of the E. coli test. In other instances, only a positive result was recorded with no indication of what the positive test result was for. The record generally records the results for both coliforms and E. coli.
Recommendation: Ensure that a minimum of four potable water samples per month are collected and analyzed for the presence of Escherichia coli and are collected randomly from locations on the forward, aft, upper, and lower decks of the vessel. Ensure that sample sites are changed each month.
Item No.: 08
Site: Potable Water-
Violation: A cross-connection control program was not available. There was no indication that the backflow protection devices on the vessel were inspected or tested.
Recommendation: Ensure that a log documenting inspection and maintenance, in written or electronic form, is maintained and available for review during inspections.
Item No.: 08
Site: Potable Water-
Violation: The free chlorine residual log for production only allowed for recording tests results once per 4-hour shift. Given this, it was possible to exceed 4 hours between tests. In addition, there were a number of days where there were gaps in the log where it appeared that a test was not conducted. These periods were for one or two 4-hour shifts.
Recommendation: Ensure that free residual halogen monitoring is performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water.
Item No.: 08
Site: Potable Water-
Violation: The end of the backwash discharge line for the mineralizer could not be identified to verify that adequate backflow protection was provided.
Recommendation: The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 08
Site: Potable Water-Bunker Stations
Violation: The drain lines from the reduced pressure backflow protection devices on the international shore connections were directed to deck sinks with no air gaps provided.
Recommendation: Provide air gaps for these backflow prevention devices.
Item No.: 08
Site: Potable Water-Port Bunker Station
Violation: The cap was missing at the end of one potable water hose.
Recommendation: Ensure that potable water hoses are stowed rolled tight with the ends capped, on reels, or racks or with ends coupled together in potable water hose lockers.
Item No.: 10
Site: Whirlpool/Spa-
Violation: The free halogen residual and contact time were not consistently recorded during shock halogenation of the whirlpools.
Recommendation: Ensure that the free residual halogen is increased to at least 10.0 mg/L (ppm) in whirlpool spas and circulated for at least 1 hour at the end of each day.
Item No.: 20
Site: Food Service General-
Violation: Slotted fasteners were noted in the ice/water contact areas of the ice machines, making cleaning difficult.
Recommendation: Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 21
Site: Galley-Main Galley - Roast Station
Violation: The rubber gasket around the window of the portside combination oven was damaged, making cleaning difficult.
Recommendation: Repair damaged rubber gasket.
Item No.: 21
Site: Other-Bistro Dining Room
Violation: Holes were noted in the door of one of the undercounter cabinets of the waiter station.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Bistro Dining Room
Violation: The edge of the top shelf of the wooden cart was damaged, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Other-Crew Mess - Buffet Line
Violation: The base of the sneeze guard was missing an end cap, leaving an opening, making cleaning difficult.
Recommendation: Replace missing end cap to sneeze guard.
Item No.: 21
Site: Provisions-Provisions - General
Violation: Some of the metal pallets were missing the end caps, leaving openings, making cleaning difficult.
Recommendation: Replace missing end caps on metal pallets.
Item No.: 24
Site: Bar-Bars - Champs
Violation: The chlorine concentration in the sanitizer bucket measured greater than 200 ppm. This item was corrected during the inspection.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 26
Site: Galley-Main Galley - Wine Cellar - Terraces
Violation: The previously cleaned soda dispenser unit was soiled and stored wrapped in clear plastic. It appears that soda dripped from the nozzles into the clear plastic wrap, soiling the dispenser paddles.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-Main Galley - Bakery/Pastry
Violation: One previously cleaned weight scale pan was slightly soiled and stored as clean. This item was corrected during the inspection.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Provisions-Provisions - Beverage Storage
Violation: The cardboard packaging to a case of liqueurs was found with a heavy mold accumulation.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Pantry-
Violation: The edges of two ice coolers lids were touching the deck in the deck 6 mid-ship pantry. The lid of an ice cooler was resting against a stack of soiled items in the Deck 7 mid-ship pantry. These coolers were said to be clean.
Recommendation: Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
Item No.: 33
Site: Other-Bistro Dining Room
Violation: The waiter stations were not coved at the deck-station juncture.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Galley-Main Galley - Bakery/Pastry
Violation: The surface coating of the scupper beneath the single compartment sink was separating along the sides, leaving a gap where food debris could collect, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Galley-Main Galley - Bakery/Pastry
Violation: Some recessed and missing grout was noted between desk tiles in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Other-Crew Mess - Buffet Line
Violation: Recessed and missing grout was noted between deck tiles in the service area of the buffet line..
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Galley-Crew Galley
Violation: Some recessed and missing grout was noted between deck tiles in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Galley-Pizzeria Galley and Sports Bar Galley
Violation: The deck-bulkhead junctures in these galley were not coved, making cleaning difficult.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Buffet-Pizzeria Buffet
Violation: The deck drain under the cold station was very heavily soiled and appeared to be clogged.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Buffet-Sports Bar Salad Bar Buffet
Violation: The deck drain was soiled.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 36
Site: Buffet-Sports Bar Buffet
Violation: Several of the overhead light bulbs were not shielded or shatter-resistant.
Recommendation: Ensure that light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 37
Site: Galley-Crew Galley
Violation: Condensate was noted collecting on the exhaust ventilation grate above the combination oven. The condensate was dripping to the equipment and deck below. It appeared the exhaust ventilation unit was working properly.
Recommendation: Ensure that exhaust ventilation hood systems in food preparation and warewashing areas including components such as hoods, fans, guards, and ducting are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 38
Site: Bar-Bars - General
Violation: The soda carbonation systems were posted not in use or out of order. According to the staff, this equipment has not worked for some time and the ship now dispenses canned sodas in the bar areas.
Recommendation: Ensure that only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 39
Site: Provisions-Provisions - General
Violation: Approximately four flies were noted in this area. The ship was actively provisioning at the time of the inspection.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 41
Site: Ventilation-ACR-306
Violation: The condensate collection pan was not accessible for inspection. The refrigeration engineer was not clear on how many other units were of similar design. In this same fan room, two other units were inspected and had pans that were accessible.
Recommendation: Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning.
*Inspections scores of 85 or lower are NOT satisfactory

Safer, Healthier People
Centers for Disease Control and Prevention, 1600 Clifton Rd, Atlanta, GA 30333, U.S.A
Tel: (404) 639-3311 / Public Inquiries: (404) 639-3534 / (800) 311-3435
FirstGov
DHHS
Department of Health
and Human Services