X19A External Homepage
Beamline X19A
General Information
Source Type Bending Magnet Status Operational General User Beamtime 50% Energy Range Category Hard X-Ray (1-50 keV) Energy Range 2.1-17 keV
Beamline Type Facility Beamline Technique(s) X-ray scattering, resonant X-ray absorption spectroscopy X-ray absorption spectroscopy, extended fine structure X-ray absorption spectroscopy, fine structure X-ray absorption spectroscopy, near edge fine structure X-ray absorption spectroscopy, near edge structure
Institution(s) Brookhaven National Laboratory Chemistry Brookhaven National Laboratory Electrochemistry NSLS ORNL UOP LLC University of Delaware Yeshiva University
Research Types X-ray absorption spectroscopy: EXAFS and XANES in biology, chemistry, physics, geology and environmental sciences, resonant x-ray diffraction of free standing liquid crystal films.
Contact Information
Spokesperson
Steven Ehrlich, Brookhaven National Laboratory, ehrlich@bnl.gov, 344-7862
Local Contact
Syed Khalid, Brookhaven National Laboratory, khalid@bnl.gov, 344-7496 Nebojsa Marinkovic, University of Delaware, marinkov@bnl.gov, 6313443808
Beamtime Scheduler
Syed Khalid, Brookhaven National Laboratory, khalid@bnl.gov, 344-7496
Beamline Phone
631-344-5619
Instrumentation
Beamline Characteristics
Energy Range |
Mono Crystal or Grating |
Resolution (ΔE/E) |
Flux |
Spot Size (mm) |
Total Angular Acceptance (mrad) |
2.1 – 16.5 keV |
Si(111) |
2 x 10-4 |
5 x 1010 ph/sec (@ 2.5 keV); 1 x 1011 ph/sec (@ 10 keV) |
2H x 1V |
3 |
Source Type Bending magnet Optical System Mirror 1: Spherical (collimating) mirror, Rh-coated glass, 3 mrad incident angle.
Monochromator: Double-crystal fixed-exit monochromator with feedback on second crystal. Mirror 2: Toroidal (focusing) mirror, Rh-coated glass. Be window: 10 µm thin Be-window. Experimental Apparatus He-purged sample-chamber with Fluorescence detector (Canberra PIPS-detector) inside chamber; Closed-cycle cryostat with special chamber to mount PIPS-detector inside vacuum. Computer System Hardware & Software Pentium PC, Windows operating system, Labview XDAC-software to operate beamline and to collect data; CAMAC-crate; Computer for data analysis (WinXas, Athena, Artemis, FEFF) available.
Links
|