[Logo: Homes and Communities: U.S. Department of Housing and Urban Development] Fair Housing and Equal Opportunity
[Vea la versión en español de esta página] [Contact Us] [Display the text version of this page] [Search/Index]
 

Fair Housing and Equal Opportunity
About FHEO
Fair housing laws
Training Academy
Partners
Fair lending
People with disabilities
Promoting Fair Housing
Economic opportunities
Senior housing
Online systems
Library

HUD news

Homes

Resources

Communities

Working with HUD

Tools
Webcasts
Mailing lists
RSS Feeds
Help

[The U.S. government's official web portal]  

Fair Housing Accessibility Guidelines cont'd

 Information by State
 Print version
 
Fair Housing Accessibility Guidelines
Table of Contents
 -   Adoption of Final Guidelines
 -   Statutory and Regulatory Background
 -   Proposed Accessibility Guidelines
 -   Public Comments and Commenters
 -   Discussion of Principal Public Comment Issues, and
Section-by-Section Analysis of the Final Guidelines
 -   Discussion of General Comments on the Guidelines ANSI Standard.
 -   Section-by-Section Analysis of Final Guidelines
 -   Discussion of Comments on Related Fair Housing
Issues Compliance Deadline
 -   Other Matters
 -   Codification of Guidelines
 -   Regulatory Impact Analysis
 -   Environmental Impact
 -   Executive Order 12606, The Family
 -   Executive Order 12611, Federalism
 -   Section 1. Introduction
 -   Section 2. Definitions
 -   Section 3. Fair Housing Act Design and Construction Requirements
 -   Section 4. Application of the Guidelines
 -   Section 5. Guidelines
 -   Requirement 1
 -   Requirements 2 and 3
 -   Requirements 4, 5, and 6
 -   Requirement 7
Requirement 4. Accessible route into and through the covered dwelling unit.
Section 100.205(c)(3)(i) provides that all covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises within covered multifamily dwelling units contain an accessible route into and through the covered dwelling unit.

Guideline
Accessible routes into and through dwelling units would meet section 100.205(c)(3)(i) if:

  1. A minimum clear width of 36 inches is provided.

  2. In single-story dwelling units, changes in level within the dwelling unit with heights between 1/4 inch and 1/2 inch are beveled with a slope no greater than 1:2. Except for design features, such as a loft or an area on a different level within a room (e.g., a sunken living room), changes in level greater than 1/2 inch are ramped or have other means of access. Where a single story dwelling unit has special design features, all portions of the single-story unit, except the loft or the sunken or raised area, are on an accessible route; and

    1. In single-story dwelling units with lofts, all spaces other than the loft are on an accessible route.

    2. Design features such as sunken or raised functional areas do not interrupt the accessible route through the remainder of the dwelling unit.

  3. In multistory dwelling units in buildings with elevators, the story of the unit that is served by the building elevator (a) is the primary entry to the unit; (b) complies with Requirements 2 through 7 with respect to the rooms located on the entry/accessible floor; and (c) contains a bathroom or powder room which complies with Requirement 7. (Note: multistory dwelling units in non-elevator buildings are not covered dwelling units because, in such cases, there is no ground floor unit.)

  4. Except as noted in paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch. Thresholds and changes in level at these locations are beveled with a slope no greater than 1:2.

  5. Exterior deck, patio, or balcony surfaces are no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed of impervious material such as concrete, brick or flagstone. In such case, the surface is no more than 4 inches below the floor level of the interior of the dwelling unit, or lower if required by local building code.

  6. At the primary entry door to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such as concrete, brick or flagstone, are no more than 1/2 inch below the floor level of the interior of the dwelling unit. The finished surface of this area that is located immediately outside the entry may be sloped, up to 1/8 inch per foot (12 inches), for drainage.

Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations.
Section 100.205(c)(3)(ii) requires that all covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises within covered multifamily dwelling units contain light switches, electrical outlets, thermostats, and other environmental controls in accessible locations.

Guideline
Light switches, electrical outlets, thermostats and other environmental controls would meet section 100.205(c)(3)(ii) if operable parts of the controls are located no higher than 48 inches, and no lower than 15 inches, above the floor. If the reach is over an obstruction (for example, an overhanging shelf) between 20 and 25 inches in depth, the maximum height is reduced to 44 inches for forward approach; or 46 inches for side approach, provided the obstruction (for example, a kitchen base cabinet) is no more than 24 inches in depth. Obstructions should not extend more than 25 inches from the wall beneath a control. (See Fig.2.)

Note
Controls or outlets that do not satisfy these specifications are acceptable provided that comparable controls or outlets (i.e., that perform the same functions) are provided within the same area and are accessible, in accordance with this guideline for Requirement 5.

 


    Requirement 6. Reinforced walls for grab bars.
    Section 100.205(c)(3)(iii) requires that covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises within covered multifamily dwelling units contain reinforcements in bathroom walls to allow later installation of grab bars around toilet, tub, shower stall and shower seat, where such facilities are provided.

    Guideline
    Reinforced bathroom walls to allow later installation of grab bars around the toilet, tub, shower stall and shower seat, where such facilities are provided, would meet section 100.205(c)(3)(iii) if reinforced areas are provided at least at those points where grab bars will be mounted. (For example, see Figs. 3, 4 and 5.) Where the toilet is not placed adjacent to a side wall, the bathroom would comply if provision was made for installation of floor mounted, foldaway or similar alternative grab bars. Where the powder room (a room with a toilet and sink) is the only toilet facility located on an accessible level of a multistory dwelling unit, it must comply with the requirement for reinforced walls for grab bars.

    Note
    Installation of bathtubs is not limited by the illustrative figures; a tub may have shelves or benches at either end; or a tub may be installed without surrounding walls, if there is provision for alternative mounting of grab bars. For example, a sunken tub placed away from walls could have reinforced areas for installation of floor-mounted grab bars. The same principle applies to shower stalls -- e.g., glass-walled stalls could be planned to allow floor-mounted grab bars to be installed later.


    Reinforcement for grab bars may be provided in a variety of ways (for example, by plywood or wood blocking) so long as the necessary reinforcement is placed so as to permit later installation of appropriate grab bars.




Back | Contents | Next

 
Content current as of July 12, 2006   Follow this link to go  Back to top   
----------
FOIA Privacy Web Policies and Important Links  Home [logo: Fair Housing and Equal Opportunity]
[Logo: HUD seal] U.S. Department of Housing and Urban Development
451 7th Street S.W., Washington, DC 20410
Telephone: (202) 708-1112   TTY: (202) 708-1455
Find the address of a HUD office near you