Escalated Enforcement Actions Issued to Reactor Licensees - R

River Bend 1 - Docket No. 050-00458

NRC Action Number(s) and
Facility Name
Action Type
(Severity) &
Civil Penalty
(if any)
Date
Issued
Description
EA-03-077
River Bend 1
NOV
(White)
12/29/2003 On December 29, 2003, a Notice of Violation was issued for a violation associated with a White SDP finding involving a loss of feedwater flow to the reactor. The violation cited the licensee’s failure to lock open the Condensate Prefilter Vessel Bypass Flow Control Valve as required by their Technical Specifications.
EA-02-036
River Bend 1
NOV
(White)
07/31/2002 On July 31, 2002, a Notice of Violation was issue for a violation associated with a white SDP finding involving emergency planning standards. The violation cited that the licensee's emergency plan was not adequate to assure that information was made available to members of the public using River Bend Station's owner controlled area regarding how members of the public would be notified of an evacuation order and what their initial actions should be in an emergency.
EA-99-158
River Bend 1
NOV
(SL III)
10/05/1999 Inadequate work instructions for the emergency diesel generator fuel booster pump that rendered the generator inoperable.
EA-98-478
River Bend 1
NOVCP
(SL III)

$ 55,000
02/01/1999 Violations relate to a design deficiency in the Division I and II emergency diesel generators (EDGs) at the River Bend Station.
EA-98-132
River Bend 1
NOVCP
(SL III)

$ 55,000
01/05/1999 Deliberately provided an NRC inspector with information that was incomplete and inaccurate.
EA-97-497
River Bend 1
NOVCP
(SL III)

$ 55,000
12/23/1997 Inadvertent mode change.
EA-96-329
River Bend 1
NOV
(SL III)
11/07/1996 Six violations of Technical Specification surveillance requirements.
To top of page

Robinson 2 - Docket No. 050-00261

NRC Action Number(s) and
Facility Name
Action Type
(Severity) &
Civil Penalty
(if any)
Date
Issued
Description
EA-04-028
Robinson 2
NOVCP
(SL II)

$88,000
04/07/2004 On April 7, 2004, a Notice of Violation and Proposed Imposition of Civil Penalty in the amount of $88,000 was issued for a Severity Level II violation for discriminating against the former Corporate Superintendent of Site Access Authorization for Carolina Power & Light for raising safety concerns
EA-98-050
Robinson 2
NOV
(SL III)
03/04/1998 Safety injection pumps outside design basis due to NPSH deficiencies.
EA-97-490
Robinson 2
NOVCP
(SL III)

$ 55,000
12/12/1997 EDG inoperability
EA-96-120
Robinson 2
NOV
(SL III)
05/16/1996 Failure to secure safeguards information.
To top of page


Privacy Policy | Site Disclaimer
Wednesday, February 21, 2007