Home
Table B26a. Analyses (ng/g [ppb] wet weight) of replicates
of NIST mussel tissue V (QA93TIS5)a for determination of the
method detection limit (MDL) for low-molecular-weight PAHs |
|
Naph-
thalene |
2-methyl-
naph-
thalene |
1-methyl-
naph-
thalene |
Biphenyl |
2,6-di-
methyl-
naph-
thalene |
Acenaph-
thylene |
Acenaph-
thene |
2,3,5-tri-
methyl-
naph-
thalene |
Fluorene |
Phen-
anthrene |
Anthra-
cene |
1-methyl-
phen-
anthrene |
Replicate 1 |
nfb |
nfb |
nfb |
nfb |
nfb |
1.34 |
nfb |
nfb |
nfb |
1.48 |
2.14 |
1.91 |
Replicate 2 |
1.03 |
1.07 |
0.81 |
0.89 |
1.03 |
0.91 |
0.81 |
nfb |
nfb |
1.84 |
1.33 |
2.02 |
Replicate 3 |
0.500 |
1.05 |
0.85 |
1.44 |
nfb |
0.91 |
1.36 |
nfb |
nfb |
2.22 |
nfb |
2.36 |
Replicate 4 |
0.43 |
1.13 |
0.36 |
0.99 |
1.44 |
nfb |
1.09 |
nfb |
nfb |
2.31 |
nfb |
nfb |
Replicate 5 |
0.53 |
0.880 |
nfb |
0.98 |
nfb |
nfb |
nfb |
nfb |
nfb |
2.28 |
nfb |
nfb |
Replicate 6 |
0.66 |
0.78 |
0.81 |
1.39 |
nfb |
nfb |
1.92 |
nfb |
nfb |
2.57 |
nfb |
nfb |
Replicate 7 |
2.44 |
1.91 |
2.06 |
2.49 |
nfb |
2.49 |
nfb |
nfb |
nfb |
5.16 |
nfb |
nfb |
Replicate 8 |
nfb |
0.47 |
nfb |
0.27 |
nfb |
nfb |
nfb |
nfb |
nfb |
1.70 |
1.07 |
1.74 |
n = |
6 |
7 |
5 |
7 |
2 |
4 |
4 |
- |
- |
8 |
3 |
4 |
Mean |
0.933 |
1.04 |
0.979 |
1.21 |
1.23 |
1.41 |
1.29 |
- |
- |
2.44 |
1.51 |
2.01 |
Std. dev. |
0.771 |
0.444 |
0.636 |
0.686 |
0.288 |
0.746 |
0.473 |
- |
- |
1.15 |
0.555 |
0.261 |
RSD (%) |
83 |
43 |
65 |
57 |
23 |
53 |
37 |
- |
- |
47 |
37 |
13 |
Student's "t" |
3.36 |
3.14 |
3.75 |
3.14 |
31.8 |
4.54 |
4.54 |
- |
- |
3 |
6.96 |
4.54 |
|
MDLc |
2.59 |
1.40 |
2.38 |
2.16 |
9.18 |
3.39 |
2.15 |
10 b |
10 b |
3.46 |
3.87 |
1.19 |
aNIST mussel tissue V (QA93TIS5) was included
in each of eight extraction
batches as a part of the QA/QC protocol.
bnf = peak not found; assuming 10 g wet weight of mussel tissue, 50%
efficiency in the sample extraction and cleanup steps, a 250L final sample colume,
and an instrument (GC/MS) detection limit of 0.2 ng/L, the MDL calculates to
be 10 ppb wet weight.
cMDL t, where = standard deviation
and t = Student's "t" value with n-1 degrees of freedom and = 0.01 (one tailed). |
Table B26b. Analyses (ng/g [ppb] wet weight) of replicates
of NIST mussel tissue V (QA93TIS5)a for determination of the
method detection limit (MDL) for high-molecular-weight PAHs |
|
Fluor-
anthene |
Pyrene |
Benz[a]-
anthra-
cene |
Chrysene |
Benzo[b]-
fluoran-
thene |
Benzo[k]-
fluoran-
thene |
Benzo[e]-
pyrene |
Benzo[a]-
pyrene |
Pery-
lene |
Indeno-
[1,2,3-
cd]
pyrene |
Dibenz-
[a,h]-
anthra-
cene |
Benzo-
[ghi]-
perylene |
Replicate 1 |
14.3 |
14.0 |
7.81 |
12.22 |
8.81 |
3.88 |
11.04 |
1.96 |
nfb |
1.37 |
nfb |
1.17 |
Replicate 2 |
13.0 |
12.2 |
6.48 |
10.53 |
6.94 |
3.39 |
8.32 |
1.76 |
nfb |
0.928 |
nfb |
0.675 |
Replicate 3 |
13.2 |
12.1 |
7.00 |
9.53 |
7.63 |
5.68 |
8.41 |
4.84 |
nfa |
5.73 |
nfa |
5.64 |
Replicate 4 |
13.8 |
12.7 |
7.75 |
10.92 |
8.48 |
3.77 |
10.78 |
2.37 |
1.66 |
nfb |
nfb |
nfb |
Replicate 5 |
12.6 |
12.0 |
7.80 |
10.45 |
6.87 |
3.57 |
8.52 |
nfb |
nfb |
nfb |
nfb |
nfb |
Replicate 6 |
10.7 |
10.5 |
6.13 |
8.58 |
5.73 |
2.88 |
7.67 |
1.74 |
nfb |
nfb |
nfb |
3.36 |
Replicate 7 |
11.6 |
10.8 |
7.15 |
8.47 |
6.70 |
5.48 |
7.21 |
4.98 |
nfb |
nfb |
nfb |
nfb |
Replicate 8 |
15.2 |
15.8 |
5.62 |
8.72 |
4.24 |
2.77 |
4.18 |
nfb |
nfb |
nfb |
nfb |
nfb |
n = |
8 |
8 |
8 |
8 |
8 |
8 |
8 |
6 |
- |
3 |
- |
4 |
Mean |
13.0 |
12.5 |
6.97 |
9.93 |
6.92 |
3.93 |
8.27 |
2.94 |
- |
2.68 |
- |
2.71 |
Std. dev. |
1.44 |
1.71 |
0.828 |
1.33 |
1.47 |
1.09 |
2.15 |
1.54 |
- |
2.65 |
- |
2.27 |
RSD (%) |
11 |
14 |
12 |
13 |
21 |
28 |
26 |
52 |
- |
99 |
- |
84 |
Student's "t" |
3 |
3 |
3 |
2.998 |
3 |
3 |
2.998 |
3.36 |
- |
6.7 |
- |
4.54 |
|
MDLc |
4.33 |
5.12 |
2.48 |
3.99 |
4.41 |
3.28 |
6.44 |
5.19 |
10b |
17.8 |
10b |
10.3 |
aNIST mussel tissue V (QA93TIS5) was included
in each of eight extraction batches as a part of the QA/QC protocol.
bnf = peak not found; assuming 10 g wet weight of mussel tissue,
50% efficiency in the sample extraction and cleanup steps, a 250L final sample
colume, and an instrument (GC/MS) detection limit of 0.2 ng/L, the MDL calculates
to be 10 ppb wet weight.
cMDL t, where = standard deviation and t = Student's "t" value
with n-1 degrees of freedom and = 0.01 (one tailed). |
Table B27
|