CHP Basics
Combined heat and power (CHP, also known as cogeneration) can provide thermal energy for buildings or processes, while simultaneously generating part of the electricity needed at the site. CHP or cogeneration is the sequential production of two forms of useful energy from a single fuel source.
Benefits
A CHP system recovers the heat from electricity generation for productive uses such as heating, cooling, dehumidification, and other processes—heat that is usually wasted at conventional power plants. And because the electricity is generated near the point of use, it is subject to fewer transmission losses than electricity supplied by distant central power plants. For these reasons, properly designed CHP systems can be more than twice as efficient as the average U.S. fossil fuel power plant. Growing numbers of federal facilities are turning to CHP technologies to gain greater control, reliability, supply quality, and flexibility in their power systems, as well as to cut costs and to meet federal energy efficiency and emissions reductions goals.
The conversion of fuels to electricity produces large quantities of waste heat as a by-product, which conventional power plants simply reject to the environment. There has been an upsurge in interest in fuel-efficient distributed energy resources such as CHP among project developers, federal facility managers, and policy makers, because these systems help to mitigate some key power sector constraints. For example, CHP systems decentralize power generation to locations near facilities having thermal requirements that can be met with waste heat. Also, CHP systems are potentially 70% - 85% efficient in utilizing fuels. And they can meet increased energy needs, reduce transmission congestion, increase power quality and reliability, and increase the energy security of a facility.
CHP was highlighted in the President's 2001 National Energy Policy Report as a technology that is commercially available today. It offers extraordinary benefits in terms of energy efficiencies and emission reductions. CHP can also facilitate a transition to cleaner fuels of the future (such as hydrogen) that would use the same infrastructure as combined heat and power.
CHP Technologies
CHP systems combine on-site power generation with the recovery and use of waste heat for making steam, heating or chilling water, or compressing air. They can use a number of technologies to generate power and use recovered heat to drive heating and cooling equipment, such as absorption chillers and desiccant dehumidifiers. These technologies include:
For more specifics on CHP and several thermally activated technologies that take advantage of waste heat, including chillers and desiccant dehumidifiers, see these DOE CHP Fact Sheets (PDF 756 KB, 6 pp). Download Adobe Reader.
The Challenge
There are still several challenges to implementing CHP projects in federal facilities:
- CHP technology is not new, but it has been applied chiefly in very large industrial systems. The technology for mid-size to large CHP systems (more than 500 kW in capacity) is well advanced. But each project still requires custom, site-specific applications engineering to design a system from commercial components and assemble them in the field. With little experience and even less performance documentation to guide them, Federal facility and energy managers could be hard-pressed to bring a CHP project to life.
- Lack of capital is a nearly universal obstacle.
- Interest in distributed energy resources such as CHP has run far ahead of policies and regulations that can accommodate them. Technical issues are often elementary compared to obstructing policies and regulations.
FEMP and other partners are addressing these challenges. Read more about it in this PowerPoint presentation: FEMP: Making CHP Accessible to Federal Agencies (PDF 1.2 MB, 28 pp). Download Adobe Reader.
FEMP's ADD CHP Program
The ADD CHP program (Accelerated Development and Deployment of CHP at Federal Sites) makes information and technical assistance on CHP technologies available to Federal agencies interested in reducing primary energy use while increasing security and flexibility through on-site power generation.
Through the ADD CHP Program, FEMP teams offer a full range of support, technical assistance, and financial guidance for CHP projects. FEMP, other groups in DOE, and the U.S. Environmental Protection Agency are addressing many of the obstacles to CHP. State public utility commissions, such as those in Texas and California, are leading the way to clarify local regulations for permitting and interconnection. And FEMP can provide expert, unbiased technical assistance specialized in CHP systems to any Federal agency interested in developing a CHP project, including:
- Free CHP quick screenings for interested Federal sites
- Site survey and feasibility verification
- Baseline data collection
- Fostering of partnerships between Federal sites and private-sector project developers and financiers
- Design and technical assistance to selected projects
- Support for addressing policy and regulatory constraints such as siting and permitting, grid interconnection requirements, exit fees, and backup charges
- Conceptual design verification
- Component matching verification
- Sizing verification—thermal/power profiles
- Technical/price proposal evaluation
If agencies need private financing, FEMP can help them identify appropriate partners (e.g., energy services companies or utilities).
The U.S. Combined Heat and Power Association (USCHPA) may also be of assistance in evaluating CHP systems for your facility. New Regional Application Centers promote CHP technology and practices, serve as a central clearinghouse for CHP information, and identify and help implement regional CHP projects (PDF 179 KB, 2 pp). Download Adobe Reader.