Note: Although this FDA-483 is an
accurate representation of the original FDA-483 issued to the firm, it is not an exact
copy. Slight modifications to the original FDA-483 have been made to accommodate its
conversion to the HTML format. A scanned copy of the original FDA-483 is available in PDF format on this website. |
DEPARTMENT
OF HEALTH AND HUMAN SERVICES
FOOD AND DRUG ADMINISTRATION |
DISTRICT
OFFICE ADDRESS AND PHONE NUMBER
USFDA/ORA/OE/DCMO (HFC-210)
5600 Fishers Lane
Rockville, MD 20857 (301) 827-0391
|
DATE(S)
OF INSPECTION 4/18-28-2006 |
FEI
NUMBER 2518760 |
NAME AND TITLE OF INDIVIDUAL TO WHOM REPORT IS ISSUED
TO: Gary K. Chikami, MD, Associate Vice President, Regulatory Affairs, North America
|
FIRM
NAME
Sanofi Pasteur, Inc. |
STREET
ADDRESS
Discovery Drive
|
CITY,
STATE AND ZIP CODE
Swiftwater, PA 18370 |
TYPE
OF ESTABLISHMENT INSPECTED
Vaccine Manufacturer
|
This document lists
observations made by the FDA representative(s) during the inspection
of your facility. They are inspectional observations, and do not
represent a final Agency determination regarding your compliance.
If you have an objection regarding an observation, or have implemented,
or plan to implement, corrective action in response to an observation,
you may discuss the objection or action with the FDA representative(s)
during the inspection or submit this information to FDA at the address
above. If you have any questions, please contact FDA at the phone
number and address above. |
DURING AN INSPECTION OF YOUR FIRM (I) (WE)
OBSERVED:
PRODUCTION SYSTEM
- The following was observed on 4/19/06 during filtration of A/Wisconsin
influenza concentrate lot U08182
- Operators performing level 1 cleaning in between pre-filtration
and sterile filtration operations were observed applying / sloshing
disinfectant to the floors of the dirty side of the class C
areas (gown room and equipment air lock) and returning to the
class B areas without re-gowning. After the required disinfectant
dwell time, the solution was vacuumed using a wet/dry vacuum
unit in the same manner.
- A common hallway (Hallway 135) is used in Building 37 without
adequate segregation of early production material from material
used in sterile processing. This hallway connects Rooms 113A
and 113B (sterile gowning suite and equipment airlock to Room
113 where the filtration of Lot U08182 was observed to occur)
and Room 140 (where egg candling was observed to occur). Egg
carts containing eggs (used in upstream influenza manufacturing)
and personnel were observed traveling into Room 140 via this
hallway during the filtration operations for Lot U08182. Personnel
conducting operations in Room 113 also were observed traveling
through this same hallway to access Rooms 113A and 113B. Contaminating
organisms found in 11 lots of monovalent influenza concentrate
that had been sterile filtered in Room 113 were identified as
primarily egg related. {Hand annotation: words “no attempt”
crossed out,; change initialed and dated}
- There is no assurance that the wet/dry vacuum used for cleaning
the floors of classified production areas prevents addition of
bioburden in the {Hand annotation: word “the” crossed
out, and the word “the” written in; changes initialed
and dated} production areas in that the HEPA filters on the unit
are not routinely integrity tested and the interior drum where
dirty solution is collected is not sanitized.
- There is no assurance that the worst-case loads are used for
the yearly validation of the Building 46 [redacted] Oven
as required by SOP A002417, Validation Maintenance Program of
Sterilization and Depyrogenation Process as Aventis Pasteur –
U.S. Validation. Specifically, not all data used to determine
worst-case items from the original 1990 studies are available.
The original report identified the 4 worst case items as follows:
1) [redacted] 2) [redacted] 3) [redacted ]
4) [redacted] However, calculation of average Fh
values from the available data from (endotoxin challenge runs)
the original validation studies show that the [redacted]
are harder to heat than the [redacted] and therefore, more
of a worst case.
- There is no assurance that training / qualification of all operators
performing aseptic operations in the flu manufacturing area is
complete. Specifically:
- TMFLU020 – Sterile Filtration training module requires
initial Aseptic Technique training and SOP A002254, Aseptic
Process Simulation (APS) Validation Requirements for the Sanofi
Pasteur-U.S. Aseptic Processing Area requires [redacted]
re-qualification through participation in a process simulation
study. Influenza Department Technician SW completed her Aseptic
Technique Qualification on 6/3/2003, but has not participated
in a media fill since her qualification. This technician has
participated in sterile filtration operations of the 2006 influenza
campaign.
- Section 3.2.3.2 of SOP A002254 states that participation of
aseptic personnel in a process simulation studies should be
tracked and maintained in personnel training files. This is
not being done for operators involved in the sterile filtration
of flu. In addition, the Q4-2005 APS report for simulation of
the Influenza Concentrate Sterile Filtration Process documents
that there were [redacted] participants in the media
fill. Review of the batch record UAPS1990 shows that only [redacted]
of those individuals signed the batch record as performing the
operation.
- Cleaning of surfaces within Grade A areas of the influenza manufacturing
facility was not consistent with SOP A002328, Requirements for
Cleaning/Disinfecting Procedures in Controlled Areas in that surfaces
were not wiped with a sterile wipe after disinfectant dwell time.
There is no assurance that the disinfectants applied without wipingdo
not inhibit growth on RODAC surface samples. Qualification studies
used to demonstrate the ability of [redacted] to support
that the growth of microorganisms is not inhibited by potential
exposure to residual antimicrobial agents found on surfaces following
cleaning did not specify how surfaces were cleaned for the study
(disinfectants allowed to dry on or wiped with sterile wipe after
dwell).
- Vent filters on the [redacted] sterile influenza bulk
concentrate tank, and on the [redacted] dispensing siphon
unit are not integrity tested.
- Monovalent influenza concentrate was sterile filtered into [redacted]
vessels without performing media simulations to determine the
impact of switching from the [redacted] stainless steel
tanks to the [redacted] glass vessels.
- [redacted] working seed lots are not being submitted
for approval before use in production. The current working seeds
lots are Lot UC1525-43 [redacted] Lot UC1507-54 [redacted]
Lot UC1605-32 [redacted] and Lot UC2018-27 [redacted]
All of these working seed lots have been used to manufacture distributed
product.
- There is no adequate backup storage for the following master
seed lots.
- There is no backup storage for Yellow Fever Master Seed Lot
C1600. In addition, there is no SOP which states where Yellow
Fever Master Seeds should be stored.
- The backup storage for [redacted] Master
Seed Lots (Lot C1525-23 for [redacted] Lot C1507-1 for
[redacted] Lot C1605-6 for [redacted] and Lot
C2018-6 for [redacted] is maintained at a temperature
of [redacted] C. This is an unlicensed temperature for
[redacted] master seeds.
- [redacted] Powders [redacted] were approved with
an 18 month expiration date. The expiration date for these powders
is routinely extended by 9 month increments up to 5 years based
on a passing potency test. This increase in expiration date has
not been approved before use of these powders in the manufacture
of distributed lots of Menomune.
- Regarding aseptic operations:
- The Suite 7 compounding area located in Room 237 of Building
46 is a Class A area used during the formulation of vaccines
for which no sterile filtration occurs after formulation including:
Tripedia, Influenza B Strain and A Strain Pools, Preserved Influenza
Final Bulks, Diptheria and Tetanus Toxoid Purified Pools and
Decavac. Menactra and Influenza No Preserved Final Bulk are
also formulated in this area. These are processed with a [redacted]
filter. Exposed lights were observed directly underneath the
HEPA filters in this area.
{Hand annotation: the letter “B” added for section
with observation #11} The following observations were made during
observation of aseptic filling operations on Filling Line 1
(for Diluent for Haemophilus b Conjugate Vaccine (Tetanus Toxoid
Conjugate) 0.4% Sodium Chloride, Lot UE910A) and/or Filling
Line 4 (for Menomune Lot UE934A):
{Hand annotation: the letter “A” crossed out and
roman numeral “i” inserted for Observation 11-B}
Empty depyrogenated vials were pushed onto the [redacted]
of Filling Line 1 using the outside of the tray that contained
the vials. This tray was exposed to a Class C environment and
may be held in such an environment for up to 14 days.
{Hand annotation: the letter “B” crossed out and
roman numeral “ii” inserted for Observation 11-B}.
An operator on Filling Line 4 used the back of forceps to move
open (partially stoppered) vials after the back of the forceps
had been in the operator’s gloved hand.
{Hand annotation: the letter “C” crossed out and
roman numeral “iii” inserted for Observation 11-B}.
An operator working at the tray off station where partially
stoppered vials were loaded onto lyophilization trays was observed
with head and upper torso over the partially stoppered vials.
- Regarding visual inspection practices:
- No specifications have been established for the light intensity
to be used during [redacted] visual inspections of unlabeled
filled containers.
- No specifications have been established for the light intensity
to be used during AQL visual inspections of unlabeled filled
containers.
- The firm has a protocol for the qualification of solutions used
in Manufacturing. This protocol (Document Number B006830 Version
Number 1.0 entitled “Master Stability Program for Buffers
and Media Reagents for AvP-US”) has been effective since
21 Dec 2004. To date only 2 of the approximately 50 materials
used in either the manufacture of products or for cleaning/disinfection
(as identified in Appendix 2 of this document) have been qualified.
- The purity, strength and quality of some critical components
in manufacturing are not tested to validate the suppliers test
results.
- [redacted] is a critical reagent in the manufacture
of meningococcal polysaccharide conjugate vaccine. This reagent
has not been tested to verify the [redacted] concentration
stated by the supplier.
- During the review OOS incident report IN04-1758, IN05-0471,
and INJ04-1483 it was observed that aberrant standards were
the root cause of OOS [redacted] content of several [redacted]
intermediates used in the manufacture of meningococcal polysaccharide
conjugate vaccine.
- Sampling of the reaction mixture during [redacted] does
not follow an appropriate procedure to prevent introduction of
objectionable chemicals and microorganisms. An operator was observed
to pour a recently withdrawn sample of the [redacted] mixture
into the [redacted] as a routine part of the sampling procedure
in a class C room.
QUALITY SYSTEM
- On-going investigations into sterility failure investigations
of 11 Influenza monvalent concentrate lots manufactured between
2/6/06 and 4/6/06 are deficient for the following reasons:
- Regarding the increased non-routine surveillance monitoring
performed to further evaluate the Building 37 Flu manufacturing
facility, there was no plan in place specifying the locations
to be tested, method of sampling, and actions to be taken when
microbial contamination was noted. Samples containing colony
forming units (CFU) were evaluated for morphological characteristics,
and only colonies exhibiting Gram-negative characteristics were
Gram stained and identified.
- The [redacted] method used for increased surveillance
monitoring of the environment has not been qualified.
- Investigational media challenge / aseptic process simulations
(APS) performed to investigate potential root cause did not
simulate the pre-filtration operations and cleaning activities
performed immediately prior to sterile filtration.
- Portions of the failed lots that had not tested positive (i.e.
failed sterility) were not re-tested to help determine the extent
of the contamination problem.
- Organisms isolated from routine environmental monitoring in
the Building 37 Flu manufacturing facility were not identified
to help determine the route of contamination. For example, between
2/22/06 and 4/4/2006, site 31 in Hallway 135 was trending upwards
until the alert level was exceeded on 4/4/2006 with a result
of [redacted] CFU.
- Annual Product Reviews (APRs) are not completed in a timely
manner. SOP A000177, Annual Product Review, dated 4/22/04, states
that APRs covering January 1 to December 31 should be finalized
by July 31 of the following year. Eight out of fourteen of the
2004 APRs were finalized after the July 31 due date. For example:
- The 2004 Menomune APR was finalized on 11/7/05.
- The 2004 DT APR was finalized on 10/28/05.
- The 2004 Td APR was finalized on 10/28/05.
- Quality Assurance review of batch production records does not
include an evaluation of the equipment sterilization records for
sterile product contact equipment.
- SWI J003642, Quality Assurance Compliance Procedure for Evaluating
and Reporting Biological Product Deviations, dated 12/29/04, states
that missed stability timepoints should be reported as BPDRs.
DT Adsorbed PF Lot U1047AA was not tested at the [redacted]
month timepoint for [redacted] These missed timepoints
were not reported.
- Complaint investigations are not always completed in timely
manner and there is no written justification for the lack of timely
completion. Of approximately 45 complaint investigations reviewed
8 were found have been completed outside of the [redacted]
day target completion time specified in SOP A000178 entitled “Procedure
for Handling Product Complaints”.
- BPDRs were not filed for complaints of glass in product. For
example, Complaint CO2005-00209 for Decavac Lot U1212CA and Complaint
CO2004-08344 for TD Lot U1188AA.
FACILITES AND EQUIPMENT SYSTEM
- The [redacted] Smoke Testing conducted as part of the
Operational Qualification Testing for the Laminar Air Flow Unit
# VLF-0067/68 Room 113, Building 37 was inadequate in that the
simulated dynamic operations were described only as“personnel
within units”. This area is used for the [redacted]
operations of Influenza virus concentrate.
- Investigations to determine product impact are not performed
when HEPA filter integrity or airfow failures are detected for
any of the classified areas including Class A areas where aseptic
filling, filtration, and formulation are performed. For example,
2 leaks (0.58% and 0.31%) were found in the Class A zone of Building
37 Room 181 (Filling Line 1) on 07 June 2005; a leak of 11.3%
was found in the Class A zone of Building 37 Room 181 (Filling
Line 1) on 05 December 2005; a leak of 0.77% was found in the
Class A zone of Building 37 Room 183 (Filling Line 4) on 23 December
2004; 4 leaks (3.69%, 0.91%, 5.11%, and 31.3%) were found in the
Class A zone of Building 37 Room 183 (Filling Line 4) on 23 December
2004. No investigations to determine the impact on products filled
under these Class A zones was performed. Additionally, 3 leaks
(0.38% 0.12%, and 0.42%) were found in the Class B zone of Building
37 Room 113 ([redacted] filtration room) on 13 September
2005. The integrity of the Class B zone filters (since this last
certification) in this room was not evaluated as part of the ongoing
investigation into the sterility failures of 11 influenza concentrates
that were filtered in this in this room.
LABORATORY CONTROLS SYSTEM
- Regarding the environmental monitoring program of manufacturing
areas:
- Routine surface sampling of the class B and C areas of Building
37 influenza manufacturing facility is not conducted under dynamic
conditions. Samples are collected after-cleaning.
- Failure to follow SOP A001939, Trending and Reporting of Environmental
Data and Establishment of Microbial Control Limits, in that
quarterly trend reports are not conducted as required.
- Regarding bioburden testing of in-process influenza vaccine:
- Qualification studies for no preservative influenza concentrate
formulation have not been performed. Samples of both non preserved
and preserved formulations are collected in [redacted]
- The 1 mL bioburden sample is not representative of the lot
size in determining pre-sterile filtration bioburden levels.
- Corrective Actions have not been fully implemented for an identified
root cause of OOS stability results for moisture of the Yellow
Fever Vaccine for both 1 dose and 5 dose final containers. This
investigation started September 2002. The root cause was identified
as transfer of residual moisture in the [redacted] The
following OOSs were observed. The expiration date is 12 months.
This is a repeat observation.
- Lot UB427AA was OOS at 12 months.
- Lot UE059AA was OOS at 6 and 12 months.
- Lot UE557AA was OOS at 6 and 9 months.
- Lot UE498AA was OOS at 6, 9, and 12 months.
- Lot UE499AA was OOS at 6, 9, and 12 months.
- Lot UB475AA was OOS at 12 months.
- Lot UB501AA was OOS at 12 months.
- Lot UB496AA was OOS at 6 months.
- Corrective Actions have not been fully implemented for an identified
root cause of OOS stability results for physical exam of Bulk
Td Adsorbed, Bulk Tripedia, Bulk Td PF Adsorbed, Bulk DT PF, Bulk
Flu, and Bulk Menactra. IN05-0974, dated 6/23/05, was initiated
to identify a root cause for the increased frequency of OOS physical
exam results since 2004. The root cause was identified as the
surrogate stability container for bulk for these products not
being suitable. This has had an effect on the following bulk stability
programs.
- Six of the eight bulk lots of TD Ads placed on stability since
2002 had resulted in OOS’s physical exam.
- Four of the seven bulk lots of DT PF placed on stability since
2002 had resulted in OOS’s for physical exam.
- Six of the twelve bulk lots of Td Ads PF placed on stability
since 2002 had resulted in OOS’s for physical exam.
- Five of the nine bulk lots of Menactra placed on stability
since 2004 had resulted in OOS’s for physical exam.
- Fifteen of the twenty bulk lots of Flu placed on stability
since 2002 had resulted in OOS’s for physical exam.
- SOP A000730, Stability Program Procedures, dated 2/2/06, states
that final stability reports are to be written. There is no due
date for writing these reports in this SOP. These final stability
reports are not finalized in a timely manner. For example:
- Final Container Tripedia Study S2001-25 was completed by November
2003. The final stability report has still not been finalized.
- Final Container Yellow Fever Study S2001-26 was completed
by January 2003. The final stability report has still not been
finalized.
- Bulk Td Adsorbed Study S2002-27 was completed by September
2004. The final stability report has still not been finalized.
- Bulk Tripedia PF Study S2003-31 was completed by September
2004. The final stability report has still not been finalized.
- At time of licensure, the stability program for Tripedia included
testing at [redacted] and [redacted] months. The
current stability program for Tripedia includes testing at [redacted]
and expiry. This reduction in stability testing was not approved.
- The following OOSs occurred during the annual stability testing
of bulk products. These bulk products went into manufacture of
finished product which has been distributed. These OOS results
were not reported as BPDRs.
- Tripedia Bulk Lot U1369 failed physical exam at 3 and 6 months.
- Td PF Adsorbed Bulk Lot U1217 failed physical exam at 9 and
12 months.
- Flu Bulk Lot U1148 failed [redacted] at 6 and 10 months.
- Flu Bulk Lot U1601 failed [redacted] at 7 months.
- Menactra Lot U2002 failed [redacted] at 1 and 2 months.
- The following analytical method validations have not been finalized.
- SWI J000144, [redacted] (Flu, Protocol B003167).
- SWI J000160, [redacted] (Flu, Protocol B003320).
- SWI J000245, [redacted] (Flu, Protocol B006472-1.0).
- SWI J000649, [redacted] (DT Related, Protocol B003146).
- SWI J000677, [redacted] (Menomune, Protocol B001991).
- SWI J000720, [redacted] (Menomune, Protocol B003305-00).
- SWI J000844, [redacted] (Multiple Products, Protocol
B007638).
- SWI J000884, [redacted] (Menomune, Protocol B007727).
- SWI J000927, [redacted] (Multiple Products, Protocol
B006875).
- SWI J000996, [redacted] (Diphtheria, Protocol B002788-00).
- SWI J001146, [redacted] (DT Related, Protocol B003144-00).
9. The SOP SWI J000197 for measuring [redacted] was not
modified to correct intermittent problems occurring with instrumentation
used in the assay. As reported in incident report IN05-1512, it
was determined that [redacted] buildup causes the HPLC to
yield intermittent retention time changes during the analysis of
for [redacted] The SOP has not been modified to address this
problem. |
FDA EMPLOYEE'S NAME, TITLE, AND SIGNATURE:
[Handwritten Signature]
Mihaly S. Ligmond, CSO
[Handwritten Signature]
Ann Marie Montemurro, CSO
[Handwritten Signature]
Robert Sausville, SCSO
[Handwritten Signature]
Tina Roecklein, CSO
[Handwritten Signature]
Willie Vann, Laboratory Chief
|
SEE
REVERSE
OF THIS
PAGE |
|
This is a modified document |
DATE
ISSUED 04/28/2006 |
FORM FDA 483 (7/00) PREVIOUS EDITION OBSOLETE
INSPECTIONAL OBSERVATIONS
Reverse Text on Page: The observations of objectional conditions and practices listed
on the front of this form are reported:
- Pursuant to Section 704(b) of the Federal Food, Drug and
Cosmetic Act, or
- To assist firms inspected in complying with the Acts and
regulations enforced by the Food and Drug Administration.
|
Section 704(b) of the Federal Food, Drug, and Cosmetic
Act (21 USC374(b)) provides: “Upon
completion of any such inspection of a factory, warehouse, consulting laboratory, or other
establishment, and prior to leaving the premises, the officer or employee making the
inspection shall give to the owner, operator, or agent in charge a report in writing
setting forth any conditions or practices observed by him which, in his judgement,
indicate that any food, drug, device, cosmetic in such establishment (1) consists in whole
or in part of any filthy, putrid, or decomposed substance or (2) has been prepared,
packed, or held under insanitary conditions whereby it may have become contaminated with
filth, or whereby it may have been rendered injurious to health. A copy of such report
shall be sent promptly to the Secretary.” |