Department of Labor Seal photos representing the workforce - digital imagery? copyright 2001 photodisc, inc.
Department of Labor Seal www.osha.gov  [skip navigational links] Search    Advanced Search | A-Z Index
Regulations (Standards - 29 CFR)
Battery charging and changing. - 1917.157

Regulations (Standards - 29 CFR) - Table of Contents Regulations (Standards - 29 CFR) - Table of Contents
• Part Number: 1917
• Part Title: Marine Terminals
• Subpart: G
• Subpart Title: Related Terminal Operations and Equipment
• Standard Number: 1917.157
• Title: Battery charging and changing.

1917.157(a)

Only designated persons shall change or charge batteries.

1917.157(b)

Battery charging and changing shall be performed only in areas designated by the employer.

1917.157(c)

Smoking and other ignition sources are prohibited in charging areas.

1917.157(d)

Filler caps shall be in place when batteries are being moved.

1917.157(e)

Parking brakes shall be applied before batteries are charged or changed.

1917.157(f)

When a jumper battery is connected to a battery in a vehicle, the ground lead shall connect to ground away from the vehicle's battery. Ignition, lights and accessories on the vehicle shall be turned off before connections are made.

1917.157(g)

Batteries shall be free of corrosion buildup and cap vent holes shall be open.

1917.157(h)

Adequate ventilation shall be provided during charging.

..1917.157(i)

1917.157(i)

Facilities for flushing the eyes, body and work area with water shall be provided wherever electrolyte is handled, except that this requirement does not apply when employees are only checking battery electrolyte levels or adding water.

1917.157(j)

Carboy tilters or siphons shall be used to handle electrolyte in large containers.

1917.157(k)

Battery handling equipment which could contact battery terminals or cell connectors shall be insulated or otherwise protected.

1917.157(l)

Metallic objects shall not be placed on uncovered batteries.

1917.157(m)

When batteries are being charged, the vent caps shall be in place.

1917.157(n)

Chargers shall be turned off when leads are being connected or disconnected.

1917.157(o)

Installed batteries shall be secured to avoid physical or electrical contact with compartment walls or components.

[62 FR 40141, July 25, 1997]


Next Standard (1917.158) Next Standard (1917.158)

Regulations (Standards - 29 CFR) - Table of Contents Regulations (Standards - 29 CFR) - Table of Contents



Back to Top Back to Top www.osha.gov www.dol.gov

Contact Us | Freedom of Information Act | Customer Survey
Privacy and Security Statement | Disclaimers
Occupational Safety & Health Administration
200 Constitution Avenue, NW
Washington, DC 20210