Power Reactor Status Report for November 15, 2002
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
Unit |
Power |
Down |
Reason or Comment |
Change in report(*) |
Number of Scrams(#) |
BEAVER VALLEY 1 |
0 |
11/11/2002 |
Cold Shutdown MAINTENANCE OUTAGE |
|
|
BEAVER VALLEY 2 |
100 |
|
|
|
|
CALVERT CLIFFS 1 |
0 |
11/08/2002 |
Cold Shutdown MAINTENANCE OUTAGE |
|
|
CALVERT CLIFFS 2 |
100 |
|
|
|
|
FITZPATRICK 1 |
100 |
|
|
|
|
GINNA 1 |
100 |
|
|
|
|
HOPE CREEK 1 |
100 |
|
|
|
|
INDIAN POINT 2 |
0 |
10/25/2002 |
Refueling REFUELING OUTAGE - CORE RELOAD COMPLETE |
* |
|
INDIAN POINT 3 |
100 |
|
|
|
|
LIMERICK 1 |
100 |
|
|
|
|
LIMERICK 2 |
100 |
|
|
|
|
MILLSTONE 2 |
98 |
|
Power Operation REDUCED POWER FOR PLANNED MAINTENANCE |
* |
|
MILLSTONE 3 |
100 |
|
|
|
|
NINE MILE POINT 1 |
100 |
|
|
|
|
NINE MILE POINT 2 |
0 |
11/11/2002 |
Cold Shutdown MAINTENANCE OUTAGE |
|
|
OYSTER CREEK 1 |
100 |
|
|
|
|
PEACH BOTTOM 2 |
100 |
|
|
|
|
PEACH BOTTOM 3 |
100 |
|
|
|
|
PILGRIM 1 |
100 |
|
|
|
|
SALEM 1 |
100 |
|
|
|
|
SALEM 2 |
100 |
|
|
* |
|
SEABROOK 1 |
100 |
|
|
|
|
SUSQUEHANNA 1 |
100 |
|
|
|
|
SUSQUEHANNA 2 |
100 |
|
|
|
|
THREE MILE ISLAND 1 |
100 |
|
|
|
|
VERMONT YANKEE 1 |
100 |
|
|
|
|
Region 2
Unit |
Power |
Down |
Reason or Comment |
Change in report(*) |
Number of Scrams(#) |
BROWNS FERRY 1 |
0 |
03/03/1985 |
Refueling DEFUELED |
|
|
BROWNS FERRY 2 |
83 |
|
Power Operation INCREASING POWER |
* |
|
BROWNS FERRY 3 |
100 |
|
|
|
|
BRUNSWICK 1 |
94 |
|
Power Operation 100% ELECTRICAL CAPABILITY |
|
|
BRUNSWICK 2 |
100 |
|
|
|
|
CATAWBA 1 |
100 |
|
|
|
|
CATAWBA 2 |
100 |
|
|
|
|
CRYSTAL RIVER 3 |
80 |
|
Power Operation REDUCED POWER FOR SCHEDULED MAINTENANCE |
* |
|
FARLEY 1 |
100 |
|
|
|
|
FARLEY 2 |
100 |
|
|
|
|
HARRIS 1 |
100 |
|
|
|
|
HATCH 1 |
100 |
|
|
|
|
HATCH 2 |
100 |
|
|
|
|
MCGUIRE 1 |
100 |
|
|
|
|
MCGUIRE 2 |
100 |
|
|
|
|
NORTH ANNA 1 |
100 |
|
Power Operation UE DECLARED DUE TO LAKE LEVEL BELOW 246.0 FT - CURRENT LAKE LEVEL IS 246.2FT. |
|
|
NORTH ANNA 2 |
0 |
09/07/2002 |
Refueling UE DECLARED DUE TO LAKE LEVEL BELOW 246.0 FT - CURRENT LAKE LEVEL IS 246.2FT REFUELING OUTAGE - DEFUELED |
|
|
OCONEE 1 |
100 |
|
|
|
|
OCONEE 2 |
0 |
10/11/2002 |
Refueling REFUELING OUTAGE - COMPLETED REFUELING |
|
|
OCONEE 3 |
0 |
11/14/2002 |
Hot Standby AUTOMATIC REACTOR TRIP - SEE EVENT# 39369 |
* |
1 |
ROBINSON 2 |
65 |
|
Power Operation FLUX MAP / NIS HOLD |
* |
|
SAINT LUCIE 1 |
100 |
|
|
|
|
SAINT LUCIE 2 |
100 |
|
|
|
|
SEQUOYAH 1 |
100 |
|
|
|
|
SEQUOYAH 2 |
100 |
|
|
|
|
SUMMER 1 |
100 |
|
|
|
|
SURRY 1 |
100 |
|
|
|
|
SURRY 2 |
100 |
|
|
|
|
TURKEY POINT 3 |
100 |
|
|
|
|
TURKEY POINT 4 |
100 |
|
|
|
|
VOGTLE 1 |
100 |
|
|
|
|
VOGTLE 2 |
0 |
11/13/2002 |
Hot Standby MAINTENANCE OUTAGE |
|
|
WATTS BAR 1 |
100 |
|
|
|
|
Region 3
Unit |
Power |
Down |
Reason or Comment |
Change in report(*) |
Number of Scrams(#) |
BRAIDWOOD 1 |
100 |
|
|
|
|
BRAIDWOOD 2 |
100 |
|
|
|
|
BYRON 1 |
100 |
|
|
|
|
BYRON 2 |
100 |
|
|
|
|
CLINTON 1 |
92 |
|
Power Operation 100% ELECTRICAL CAPABILITY |
|
|
COOK 1 |
100 |
|
|
|
|
COOK 2 |
100 |
|
|
|
|
DAVIS BESSE 1 |
0 |
02/15/2002 |
Refueling REFUELING OUTAGE - DEFUELED |
|
|
DRESDEN 2 |
96 |
|
Power Operation 100% ELECTRICAL CAPABILITY |
|
|
DRESDEN 3 |
97 |
|
Power Operation 100% ELECTRICAL CAPABILITY |
|
|
DUANE ARNOLD 1 |
94 |
|
Power Operation 100% ELECTRICAL CAPABILITY |
|
|
FERMI 2 |
100 |
|
|
|
|
KEWAUNEE 1 |
100 |
|
|
|
|
LASALLE 1 |
100 |
|
|
|
|
LASALLE 2 |
100 |
|
|
|
|
MONTICELLO 1 |
100 |
|
|
|
|
PALISADES 1 |
100 |
|
|
|
|
PERRY 1 |
100 |
|
|
|
|
POINT BEACH 1 |
100 |
|
|
|
|
POINT BEACH 2 |
100 |
|
|
|
|
PRAIRIE ISLAND 1 |
91 |
|
Power Operation COASTING DOWN FOR REFUELING |
* |
|
PRAIRIE ISLAND 2 |
100 |
|
|
|
|
QUAD CITIES 1 |
0 |
11/05/2002 |
Refueling REFUELING OUTAGE |
|
|
QUAD CITIES 2 |
97 |
|
Power Operation HOLDING FOR POWER UPRATE |
|
|
Region 4
Unit |
Power |
Down |
Reason or Comment |
Change in report(*) |
Number of Scrams(#) |
ARKANSAS NUCLEAR 1 |
100 |
|
|
* |
|
ARKANSAS NUCLEAR 2 |
100 |
|
|
|
|
CALLAWAY 1 |
0 |
10/22/2002 |
Refueling REFUELING OUTAGE |
|
|
COLUMBIA GENERATING |
100 |
|
|
|
|
COMANCHE PEAK 1 |
0 |
11/11/2002 |
Hot Shutdown SHUTDOWN FOR PLANNED MAINTENANCE |
* |
|
COMANCHE PEAK 2 |
100 |
|
|
|
|
COOPER 1 |
100 |
|
|
|
|
DIABLO CANYON 1 |
0 |
10/20/2002 |
Cold Shutdown SCHEDULED MAINTENANCE OUTAGE |
|
|
DIABLO CANYON 2 |
100 |
|
|
|
|
FT CALHOUN 1 |
100 |
|
|
|
|
GRAND GULF 1 |
100 |
|
|
|
|
PALO VERDE 1 |
99 |
|
|
* |
|
PALO VERDE 2 |
98 |
|
Power Operation TEMPERATURE LIMITED |
|
|
PALO VERDE 3 |
99 |
|
|
|
|
RIVER BEND 1 |
100 |
|
|
|
|
SAN ONOFRE 2 |
100 |
|
|
|
|
SAN ONOFRE 3 |
100 |
|
|
|
|
SOUTH TEXAS 1 |
100 |
|
|
|
|
SOUTH TEXAS 2 |
0 |
10/01/2002 |
Refueling REFUELING OUTAGE - DEFUELED |
|
|
WATERFORD 3 |
100 |
|
|
|
|
WOLF CREEK 1 |
100 |
|
|
|
|
* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours
Notes:
- Reactor status data collected between 4 a.m. and 8 a.m. each day.
- All times are based on eastern time.
|