Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100     *  
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 0 03/23/2008 REFUELING OUTAGE    
Indian Point 3 100   FEEDER 95332 OOS FOR SCHEDULED MAINTENANCE. *  
Limerick 1 100        
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 0 03/21/2008 REFUELING OUTAGE    
Oyster Creek 92   HOLDING POWER FOR CONTROL VALVE OSCILLATION PROBLEM AND FEEDWATER HEATER ISSUES    
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 97   500 KV LINE OOS FOR MAINTENANCE INCREASING POWER *  
Salem 2 0 03/11/2008 DEFUELED 500 KV LINE OOS FOR MAINTENANCE    
Seabrook 1 0 03/31/2008 REFUELING OUTAGE *  
Susquehanna 1 0 03/03/2008 REFUELING OUTAGE    
Susquehanna 2 100   VOLTAGE REGULATOR IN MANUAL    
Three Mile Island 1 100        
Vermont Yankee 43   REDUCED POWER FOR CONDENSER MAINTENANCE *  

Region 2

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 0 03/18/2008 REFUELING OUTAGE    
Brunswick 1 0 03/14/2008 REFUELING OUTAGE - FUEL MOVEMENT IN PROGRESS *  
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 92   INCREASING POWER *  
Hatch 2 100        
McGuire 1 100        
McGuire 2 0 03/01/2008 REFUELING OUTAGE    
North Anna 1 100   230 KV LINE 255 OOS 3/31 - 4/7    
North Anna 2 100   230 KV LINE 255 OOS 3/31 - 4/7    
Oconee 1 73   HOLDING POWER UNTIL OUTAGE; 1A1 RCP SHUT DOWN    
Oconee 2 0 03/31/2008 AUTOMATIC REACTOR TRIP. SEE EN# 44109. * 1
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 87   HOLDING POWER WHILE TROUBLESHOOTING SECONDARY CHEMISTRY ISSUE INVOLVING ONE CIRC WATER PUMP    
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 0 03/30/2008 REFUELING OUTAGE *  
Vogtle 1 0 03/15/2008 DEFUELED    
Vogtle 2 98   100% ELECTRICAL CAPABILITY    
Watts Bar 1 100     *  

Region 3

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 0 03/23/2008 DEFUELED    
Byron 2 100        
Clinton 96   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 0 03/25/2008 REFUELING OUTAGE    
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 98   100% ELECTRICAL CAPABILITY    
Dresden 3 98   100% ELECTRICAL CAPABILITY    
Duane Arnold 98   100% ELECTRICAL CAPABILITY    
Fermi 2 100        
Kewaunee 0 03/28/2008 SCHEDULED REFUELING OUTAGE    
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 96   LOWERED POWER DUE TO RECIRC PUMP SCOOP TUBE CONTROL ISSUES *  
Quad Cities 2 60   HOLDING POWER FOR TESTING *  

Region 4

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 0 03/16/2008 REFUELING OUTAGE    
Callaway 100        
Columbia Generating Station 97   INCREASING POWER *  
Comanche Peak 1 100        
Comanche Peak 2 0 03/29/2008 REFUELING OUTAGE    
Cooper 86   COASTDOWN TO REFUELING OUTAGE *  
Diablo Canyon 1 100   230 KV LINE MORBAY - MIDWAY #2 OOS FROM 4/2 - 4/4 *  
Diablo Canyon 2 0 02/03/2008 CORE RELOAD COMPLETE. 230 KV LINE MORBAY - MIDWAY #2 OOS FROM 4/2 - 4/4 *  
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 0 03/28/2008 SCHEDULED REFUELING OUTAGE    
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 99     *  
San Onofre 3 99     *  
South Texas 1 0 03/29/2008 REFUELING OUTAGE    
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 0 03/17/2008 REFUELING OUTAGE DEFUELED    