NRC Regulatory Issue Summary 2002-04
Results of the Pilot Test of the Proposed Changes to the Unplanned Scrams
Performance Indicator and
the Scrams with Loss of Normal Heat Removal Performance Indicator
March 1, 2002
Addresses
All holders of operating licenses for nuclear power reactors, except
those who have permanently ceased operations and have certified that fuel
has been permanently removed from the reactor vessel.
Intent
The U.S. Nuclear Regulatory Commission (NRC) is issuing this Regulatory
Issue Summary (RIS) to inform power reactor licensees of the results of
a 6-month pilot test of proposed changes to the "unplanned scrams
per 7,000 critical hours" and the "scrams with loss of normal
heat removal" performance indicators (PIs) in the Reactor Oversight
Process (ROP).
The NRC/Industry Working Group evaluated the pilot results using the guidelines
in RIS 2000-21, "Changes to the Unplanned Scram and Unplanned Scram with
Loss of Normal Heat Removal Performance Indicators." Based on the results
of the pilot test, the NRC has concluded that the replacement indicators would
not be as effective or reduce the potential for unintended consequences. Therefore,
the current unplanned scrams per 7,000 critical hours PI will not be changed.
The definition of the unplanned scrams with loss of normal heat removal PI
will be slightly revised.
![To top of page](https://webarchive.library.unt.edu/eot2008/20081014215625im_/http://www.nrc.gov/images/navigation/go-top.gif)
Background Information
On March 28, 2000, senior NRC and industry managers met to discuss industry's
concern regarding potential adverse impact of the current scram indicators.
Some industry representatives indicated that including manual scrams in
the current scram PIs could potentially result in nonconservative decision-making
by operators during a plant event for which a manual scram is warranted.
To address these concerns, the industry proposed two replacement PIs,
"unplanned reactor shutdowns per 7,000 critical hours" and "unplanned
reactor shutdowns with loss of normal heat removal."
The NRC/Industry Working Group, which consists of NRC management and
staff, Nuclear Energy Institute (NEI) management, and senior industry
representatives, met in monthly meetings to refine the proposed replacement
scram indicators, plan a pilot test, and develop the criteria to be used
to evaluate the pilot results. In developing and evaluating the proposed
replacement PIs, the NRC/Industry Working Group followed the formal process
that is documented in Inspection Manual Chapter 0608, "Performance
Indicator Program."
The 6-month pilot test began in October 2000. The plants that participated
in the pilot were James A. FitzPatrick; Salem Units 1 and 2; Hope Creek; Shearon
Harris; Joseph M. Farley Units 1 and 2; Vogtle Units 1 and 2; Edwin I. Hatch
Units 1 and 2; Dresden Units 2 and 3; Prairie Island Units 1 and 2; Palo Verde
Units 1, 2, and 3; Diablo Canyon Units 1 and 2; and Fort Calhoun. Upon completion
of the pilot, the data were evaluated to determine if the proposed replacement
PIs were as effective as the current PIs at indicating performance in the
initiating events cornerstone and more effective at minimizing the potential
for unintended consequences.
Some industry representatives expressed the concern that including manual
scrams in the current PIs could potentially result in nonconservative decisionmaking
during a plant event for which a manual scram may be warranted. As a result
of these concerns, the NRC and industry pilot-tested proposed replacement
PIs to evaluate their effectiveness and accuracy to determine if they should
be adopted.
The NRC/Industry Working Group used the five criteria delineated in RIS
2000-21 to evaluate the data from the 6-month pilot test. The criteria
and results of the evaluation are as follows:
![To top of page](https://webarchive.library.unt.edu/eot2008/20081014215625im_/http://www.nrc.gov/images/navigation/go-top.gif)
Some industry representatives expressed the concern that including manual
scrams in the current PIs could potentially result in nonconservative decisionmaking
during a plant event for which a manual scram may be warranted. As a result
of these concerns, the NRC and industry pilot-tested proposed replacement
PIs to evaluate their effectiveness and accuracy to determine if they should
be adopted.
The NRC/Industry Working Group used the five criteria delineated in RIS
2000-21 to evaluate the data from the 6-month pilot test. The criteria
and results of the evaluation are as follows:
- Criteria: Differences between data collected for the "unplanned
reactor shutdowns per 7,000 critical hours" and "unplanned
scrams per 7,000 critical hours" PIs.
Results: There were no differences between the data collected in
the pilot test of the proposed unplanned reactor shutdowns per 7,000 critical
hours PI and the current unplanned scrams per 7,000 critical hours PI. The
same eight scrams were reported by the 13 pilot plants under each indicator.
The NRC staff also reviewed the licensee event report (LER) database for
all scrams reported by the industry in 2000 (before the pilot test) to identify
any events that would likely not have been reported under the replacement
PIs if they had occurred during the trial. The staff found 13 such scrams
(about 14 percent of the 92 scrams that year). As a result, the NRC determined
that implementation of the proposed replacement PI as proposed would likely
not have captured all reactor scrams. Needed changes to the proposed PI
to address this concern would not be simple or necessarily effective.
- Criteria: Comparability of the data reported for the "unplanned
reactor shutdowns with loss of normal heat removal" and the "scrams
with a loss of normal heat removal" PIs. Additionally, the NRC would
compare the rate of occurrence of "unplanned reactor shutdowns with
loss of normal heat removal" and the scrams with loss of normal heat
removal results presented in NUREG/CR-5750, "Rates of Initiating Events
at U.S. Nuclear Power Plants 1987-1995" (Sections: Loss of Feedwater
and Loss of Heat Sink Events), to identify differences.
Results: According to NUREG/CR-5750, the expected number of scrams
with loss of normal heat removal for the pilot plants is 2.42 events
per 6 months. Two of these events were reported during the pilot (a
good correlation), but none were reported under the existing ROP guidance.
The two events captured in the pilot should have been captured in the
existing PI data. Early in the initial implementation of the ROP and
before the pilot, the NRC/Industry Working Group became aware of problems
in the definition of "loss of normal heat removal" in the
existing guidance. Consequently, the NRC/Industry Working Group developed
a revised definition and tested it during the pilot, along with a revised
definition of "scrams." The pilot results demonstrated that
the revised definition of "loss of normal heat removal" should
be included in the ROP guidance regardless of which PI is employed.
- Criteria: Ability of licensees to report the requested data
accurately and with minimal need for clarification.
Results: The pilot test results did not favorably indicate the licensee's
ability to report the replacement PI data accurately and with minimal need
for clarification. A significant number of reactor scrams would likely be
missed by the proposed replacement indicators. A simple clarification in
the guidance would have captured six of the 13 scrams in the year 2000 that
might have been missed. The NRC/Industry Working Group attempted, but was
not able to develop, a simple and effective clarification for the other
seven scrams. Therefore, the staff concluded that the proposed replacement
indicators would likely not provide the same data as provided by the current
PIs.
- Criteria: Ability of each alternate PI to reduce the potential
for unintended consequences without introducing other unintended consequences.
Results: The proposed alternative PIs did not demonstrate the
ability to reduce the potential for creating unintended consequences
below those which might be postulated using the existing scram PIs.
For example, it has been suggested that continued use of the current
scram PIs may result in operators not initiating a manual scram when
needed to avoid a PI "hit," which would be counter to safety-conscious
operation. However, the proposed replacement PIs do not resolve this
concern.
- Criteria: Whether there are minimal changes in reporting burden
for licensees.
Results: Based on the review of the pilot experience, the proposed
replacement indicators would not increase the regulatory burden of reporting
data. However, two clarifications would be needed to ensure that accurate
data are reported. One clarification would be straightforward, the other
would not. The more complex clarification could increase licensee reporting
burden by requiring more interaction with the staff to ensure data accuracy.
In summary, the replacement PIs would likely miss some of the scrams that
would be captured by the existing PIs. Changes to address this concern would
further complicate the PIs and would require increased effort on the part
of the NRC and the industry to ensure that they are reported accurately. Finally,
the replacement PIs would not decrease and would likely increase any potential
for unintended consequences.
Based on the results of the pilot test, as evaluated by the NRC/Industry
Working Group in accordance with the formal change process, the NRC has
decided to retain the existing scram PIs and not to adopt the proposed
replacement PIs. However, the definition and the clarifying notes in the
current "loss of normal heat removal" PI were revised in NEI
99-02, "Regulatory Assessment Performance Indicator Guideline,"
Rev. 2. This document was made available to the public on January 1, 2002.
.
Backfit Discussion
This RIS requires no action or written response. Any action on the part
of addresses to collect and transmit PI data is strictly voluntary and,
therefore, is not a backfit under 10 CFR 50.109. Therefore, the staff
did not perform a backfit analysis.
![To top of page](https://webarchive.library.unt.edu/eot2008/20081014215625im_/http://www.nrc.gov/images/navigation/go-top.gif)
Federal Register Notification
A notice of opportunity for public comment on this RIS was not published
in the Federal Register because the NRC has worked closely with NEI,
industry representatives, members of the public, and other stakeholders since
early 1998 on the development of NRC's ROP, including the collection of PI
data. A January 10, 2001, Federal Register notice solicited written
comments by April 13, 2001, on all aspects of the new ROP. A three-day public
workshop for external stakeholders was held in late March, 2001. Monthly public
meetings on the PI process and other ROP issues were held during spring 2001,
at which time the pilot PI effort was discussed and interested stakeholders
were given the opportunity to comment.
![To top of page](https://webarchive.library.unt.edu/eot2008/20081014215625im_/http://www.nrc.gov/images/navigation/go-top.gif)
Paperwork Reduction Act Statement
This RIS does not request any information collection; therefore, this RIS
is not subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.).
If you have any questions about this matter, please telephone or email
the technical contact listed below.
![To top of page](https://webarchive.library.unt.edu/eot2008/20081014215625im_/http://www.nrc.gov/images/navigation/go-top.gif)
|
/RA/
William D. Beckner, Program Director
Operating Reactor Improvements Program
Division of Regulatory Improvement Programs
Office of Nuclear Reactor Regulation
|
Technical contact: |
Serita Sanders, NRR
(301) 415-2956
E-mail: sxs5@nrc.gov |
ADAMS Accession Number ML013510432
- Public Law 91-190.
|