Protecting People and the EnvironmentUNITED STATES NUCLEAR REGULATORY COMMISSION
UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D. C. 20555
November 20, 1980
TO ALL POWER REACTOR LICENSEES (EXCEPT SEP LICENSEES)
RE: TECHNICAL SPECIFICATION REVISIONS FOR SNUBBER SURVEILLANCE
Enclosed is a copy of Revision 1 of the Inservice Surveillance Requirements
for snubbers under the Standard Technical Specifications. This revision
embodies several changes, clarifications, and improvements from the previous
version based on recent operating experience. This revision also includes
surveillance requirements for mechanical snubbers.
We request that you submit a license amendment application to incorporate
the applicable portion of these model Technical Specifications into your
Appendix "A" Technical Specification within the next 120 days.
In case you have questions, please contact H. Shaw, 492-7364.
Sincerely,
Darrell G. Eisenhut, Director
Division of Licensing
Enclosure:
Standard Technical Specifications Snubber
Surveillance Requirements
cc w/encl. for information:
See Service List
SEP Licensees