Protecting People and the EnvironmentUNITED STATES NUCLEAR REGULATORY COMMISSION
GL80037
UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D.C. 20555
May 7, 1980
TO ALL OPERATING REACTOR LICENSEES
SUBJECT: FIVE ADDITIONAL TMI-2 RELATED REQUIREMENTS TO OPERATING REACTORS
Gentlemen:
Over the past few months, the NRC has been developing its requirements that
flow from various reviews following the TMI accident of March 28, 1979. All
TMI-related issues are being included in the NRC's TMI Action Plan. On
September 13, 1979, you were informed of the first set of TMI-related
actions based upon Lessons Learned that were required for operating
reactors.
On February 8, 1980, the Commission preliminarily approved the Near-Term
Operating License requirements of the TMI Action Plan. There are five items
that are applicable to operating reactors and constitute a second set of
requirements for operating reactors. They are as follows: (1) I.A.1.3-Shift
Manning; (2) I.A.3.1 - Licensing Examinations: (3) I.C.5 - Licensee
Dissemination of Operating Experiences; (4) II.K.3 - LOFW and Small Break
LOCA Generic Review Matters; and (5) III.D.3.4 - Control Room Habitability.
These matters are specified in the Task Action Plan (NUREG 0660, May 1980).
Items 1, 2, 3, and 5 involve actions for all reactor plants whereas item 4
concerns only specific light water reactor types. Item 4 involves 28
separate actions; i.e., 15 for BWR plants (including 1 for Big Rock); 7 for
PWR plants (including 3 for Westinghouse designs); and 6 for all light water
reactor plants. Five of the items are applicable to Fort St. Vrain.
Requirements for the implementation of each of these actions are provided in
this letter, except for items (1) and (2). Item (1) will be provided
shortly through separate correspondence and Item (2) was provided to you by
letter dated March 28, 1980.
The implementation schedule for the five action items as they apply to the
various operating reactor designs is given in Enclosure (1). Enclosure (2),
(3) and (4) are specific with regard to the three remaining items as they
apply to any specific plant design. Each enclosure consists of two parts;
i.e., the first part is the staff requirement and the second part is a copy
of the applicable section of the plan. The NUREG reports re enced in these
enclosures will be provided to you shortly through separate correspondence.
.
- 2 -
Each of the specific actions includes an implementation schedule as to how
and when the particular action is to be carried out. three classes are
indicated: i.e., Class 1 involves no hardware changes and requires that the
actions to be implemented by the specified date; Class 2 involves possible
hardware changes that may be effected without prior staff review and Class 3
involves hardware changes that would be made subsequent to staff review and
approval.
You are requested to reply within 30 days stating your commitment to meet
these requirements and associated schedules.
Sincerely,
Darrell G. Eisenhut, Director
Division of Licensing
Enclosures:
Additional Operating
Requirements as Stated