UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D.C. 20555
September 19, 1983
TO ALL OPERATING REACTOR LICENSEES, APPLICANTS FOR AN OPERATING LICENSE AND
HOLDERS OF CONSTRUCTION PERMITS FOR BABCOCK & WILCOX PRESSURIZED WATER
REACTORS
Gentlemen:
SUBJECT: SAFETY EVALUATION OF "ABNORMAL TRANSIENT OPERATING GUIDELINES"
(GENERIC LETTER 83-31)
The NRC staff has reviewed the proposed Oconee Nuclear Station, Unite 3
Abnormal Transient Operating Guidelines (ATOG) as described in Babcock &
Wilcox (B&W) Owners Group letters dated March 31, 1982 and June 15, 1982,
and D. Napiors letter from B&W to the Owners Group dated March 14, 1983. As
discussed in the enclosed letter to the B&W Owners Group we have concluded
that ATOG is acceptable as a basis for implementation of improved plant
specific procedures and will provide improved guidance for operator
emergency procedures over that which currently exists. Since there is no
generic version of ATOG for B&W plants, the utilities who are participating
in the Owners Group program are to provide sufficient documentation in the
form of plant-specific ATOGs and Transient Information Documents (TIDs) so
that the NRC can perform comparisons with the ATOG version evaluated in the
enclosed Safety Evaluation Report (SER). We suggest that implementation of
the guidelines proceed in 4 steps:
(1) Interim extension of ATOG to better cover ATWS and certain aspects
of natural circulation;
(2) Preparation of plant specific procedures which, in general, conform to
the ATOG referenced above and implementation of these procedures as
required by Generic Letter 82-33, dated December 17, 1982;
(3) Preparation of supplements to the guidelines which cover changes, new
equipment, or new knowledge and incorporation of these supplements into
the procedures; and
(4) Completion and improvement of the guidelines to meet our long term
requirements, followed by incorporation of improvements into plant
specific procedures.
Step 1 is to be completed before ATOG is used in the implementation of
procedures process. The prompt implementation of Step 2 will allow the
benefits of the significant improvements you have achieved to be realized
soon. We note however, that the guidelines are written for the procedure
writers, not control room operators, and therefore, preparation and
8309190017
.
- 2 - September 19, 1983
implementation of procedures will require additional Human Factors input.
Step 3 refers to a program for guideline or procedure updates which will be
generated as a matter of routine after the implementation. This essentially
is a maintenance function. Step 4 refers to a program for addressing those
aspects of the guidelines and procedures where additional long term work may
be needed in your emergency procedure program.
We have identified in the Safety Evaluation Report (SER) a number of items
associated with the guidelines which need further work by the B&W Owners.
We require that these items be addressed by either incorporating them into a
future guideline revision or otherwise justifying the disposition of the
item. The Owners Group letter of May 4, 1983 provided a satisfactory outline
of a plan to change the existing ATOG to a more generic document. We share
the Owners Group judgement that a B&W generic technical guideline will
provide an effective mechanism for future guideline updates, changes and
enhancements. Additionally, because the Abnormal Transient Operating
Guidelines must be dynamic in that changes must be made to reflect change in
equipment or new knowledge, we expect the B&W Owners' Group or a similar
coalition of utilities and vendors to accept responsibility for continued
maintenance of the guidelines. Therefore, we have requested in the enclosed
letter that the B&W Owners' Group provide a plan for addressing the SER
items and a description of the program for steps 3 and 4 above.
As discussed in the enclosed SER, the staff finds that ATOG represents a
significant improvement over the guidance provided in current emergency
operating procedures. ATOG is symptom oriented, considers multiple
failures, is tolerant of operator error, addresses plant cooldown following
an emergency, and addresses inadequate core cooling. We find the approach
used in ATOG to be responsive to the staff's criteria. Further, ATOG
contains a significant quantity of valuable information for the guidance of
operators under emergency conditions. The guidelines provide sufficient
guidance such that they can be translated into acceptable emergency
operating procedures using the process identified in NUREG-0899, "Guidelines
for the Preparation of Emergency Operating Procedures." The staff therefore
concludes that although efforts to improve the guidelines should continue,
ATOG will provide a greater assurance of operational safety and are
acceptable for implementation.
Sincerely,
Darrell G. Eisenhut, Director
Division of Licensing
Enclosures:
1. Letter to Mr. Whitney,
dated September 19, 1983
2. SER on Guidelines
|