Protecting People and the EnvironmentUNITED STATES NUCLEAR REGULATORY COMMISSION
UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D.C. 20555
April 15, 1982
TO ALL BOILING WATER REACTOR PLANT LICENSEES AND APPLICANTS
Gentlemen:
SUBJECT: TRANSMITTAL OF NUREG-0909 RELATIVE TO THE GINNA TUBE RUPTURE
(Generic Letter No. 82-07)
On January 25, 1982, the R. E. Ginna Nuclear Power Plant experienced a
rupture of a steam generator tube. Shortly after the event, Chairman
Palladino directed that a task force be established to gather and report on
the factual information surrounding the event.
The task force has now completed its investigation and has documented the
factual information and their findings associated with the event (See
Enclosed NUREG-0909).
This report is being provided for your information only.
Sincerely,
Darrell G. Eisenhut, Director
Division of Licensing
Office of Nuclear Reactor Regulation
Enclosure:
NUREG-0909
8204160152