Home > Electronic Reading Room > Document Collections > ACRS > Schedules and Agendas > 2003
> Reliability and Probability Risk Assessment Subcommittee Meeting
ADVISORY COMMITTEE ON REACTOR SAFEGUARDS
MEETING OF THE SUBCOMMITTEE ON RELIABILITY AND PROBABILITY RISK ASSESSMENT
ROOM T-2B3, 11545 ROCKVILLE PIKE, ROCKVILLE, MARYLAND January 23 and 24, 2003 ACRS
Contact: | Michael R. Snodderly (301) 415-6927 | | | E-mail:
mrs1@nrc.gov | | -
PROPOSED SCHEDULE - | | | | | | TOPIC | PRESENTER | TIME | Thursday,
January 23, 2003 | | | 1. | Introduction |
| 8:30-8:35 am | | - Review
goals and objectives for this meeting
| George Apostolakis,
ACRS Mike Corletti, Westinghouse |
| 2. | Overview
of AP1000 Design | Terry Schulz, W | 8:35-10:05
am | | - Design
Changes from AP600
- Key AP1000 Key Design Features
- Defense in Depth
- PRA
as a Design Tool
| |
| | **BREAK*** | | 10:05
- 10:20 am | 3. | AP1000
PRA | Selim Sancaktar, W | 10:20
- 12:20 pm | | - Background
/ Approach / Overview
- Scope
- Level 1 PRA Internal Events At-Power,
Including Uncertainty
- Shutdown / Fire PRA
| | | | **LUNCH*** | | 12:20
- 1:30 pm | 4. | PRA
Level 1 Success Criteria | Terry Schulz,
W | 1:30 - 3:30 pm | | - Overview
- Thermal-Hydraulic
Analysis to Support Level 1 PRA
- T&H Uncertainty Assessment
| | | | **BREAK*** | | 3:30
- 3:45 pm | 5. | NRC
Staff Presentation | Nick Saltos, NRR Walt
Jensen,NRR Marie Pohida, NRR | 3:45 - 5:30
pm | | - Staff
RAIs on Level 1 PRA and Success Criteria
| | | 6. | Westinghouse
Summary | Mike Corletti, W |
5:30-5:45 pm | Friday, January 24,
2003 | 1. | Introduction | | 8:30-8:35
am | | - Review
goals and objectives for this meeting
| George
Apostolakis, ACRS Mike Corletti, Westinghouse | | 2. | Level
2 and 3 PRA | Jim Scobel, W | 8:35-10:15
am | | - Quantification
- Level
2 Phenomenological Studies
| | | | **BREAK*** | | 10:15-10:30
am | 3. | ULPU
Testing Performed for AP 1000 | Jim Scobel,
W | 10:30-11:30 am | | - AP600
Background
- Test Program
- RV Insulation Design
| | | 4. | PRA
Importance and Sensitivity Studies | Selim
Sancaktar, W | 11:30-12:15 pm | | **LUNCH*** | | 12:15
- 1:15 pm | 5. | Staff
Presentation | Bob Palla, NRR Richard
Lee, RES | 1:15-2:15 pm | | - Staff
RAIs on Level 2 & 3 P
| | | 6. | Westinghouse
Summary | Mike Corletti, W | 2:15-2:30
pm | 7. | General
Discussion and Adjournment | | 2:30-3:00
pm | | - General
Discussion and comments by members of the Subcommittee
| George
Apostolakis, ACRS | |
Note: - Presentation time should not exceed
50% of the total time allocated for a specific item.
- Number of
copies of presentation materials to be provided to the ACRS - 35.
|