Contact: P. Boehnert (301/415-8065 - pab2@nrc.gov
|
TOPIC
| SPEAKER
| TIME
|
November 13, 2000 |
|
|
I. |
Introduction |
G. Wallis, Chairman |
8:30 a.m. |
II. |
GE Nuclear Energy Presentation: |
|
|
|
TRACG Code (Closed - all or part) |
|
|
|
A. Introduction |
J. Klapproth |
8:45 a.m. |
|
B. Technical presentation |
JGM Andersen,
FT Bolger,
CL Heck |
|
|
|
- What is TRACG and it's intended application?
- Licensing requirements
- Submittals
|
|
|
|
|
|
Approach: CSAU |
|
|
|
|
|
(Stress application rather than generic descriptions) |
|
|
|
Step |
Description |
Application LTR
or Other Reference |
|
|
1 |
Scenario Specification |
Section 2.7 |
|
|
2 |
Nuclear Power Plant Selection |
Section 2.8 |
|
|
3 |
Phenomena Identification and Ranking |
Section 3.0 |
|
|
4 |
Frozen Code Version Selection |
Model LTR, ECP control |
|
|
5 |
Code Documentation |
Model LTR, ECP docs. |
|
|
6 |
Determination of Code Applicability
(Presentation of TRACG models and their applicability) |
Sec. 4.1, Qual. & Model
LTR |
|
|
7 |
Establishment of Assessment Matrix
(Summary of TRACG assessment) |
Section 4.2 |
|
|
8 |
Nuclear Power Plant Nodalization Definition
(Basis for BWR nodalization and sensitivity studies) |
Section 5.2, Qual. LTR |
|
|
9 |
Definition of Code and Experimental Accuracy
(Summary of PIRT uncertainties) |
Section 5.1, Qual. LTR |
|
|
10 |
Determination of Effect of Scale
(Qualification against full scale BWR plant data) |
Section 5.3, Full scale
data |
|
|
11 |
Determination of the Effect of Reactor Input Parameters and State
|
Section 6.0 |
|
|
12 |
Performance of Nuclear Power Plant Sensitivity |
Sections 7.0 and 8.0 |
|
|
13 |
Determination of Combined Bias and Uncertainty |
Sections 7.0 and 8.0 |
|
|
14 |
Determination of Total Uncertainty
(Confirmation of code uncertainty and demonstration cases) |
Sections 7.0 and 8.0 |
|
|
|
|
|
|
III. |
NRC Presentation (Open) |
R. Landry, NRR |
6:00 p.m. |
|
- Status of Code Review
- Future Actions/Schedule Milestones
|
|
|
IV. |
Subcommittee Caucus (Open) |
|
6:30 p.m. |
|
|
- Follow-on Items for this Issue
- Future Actions
- Committee Action
|
|
|
V. |
Recess |
|
6:45 p.m. |
November 14, 2000 |
|
|
VI. |
Reconvene |
G. Wallis, Chairman |
8:30 a.m. |
V. |
NRC RES Presentation:
T/H Phenomena Research Program |
|
|
|
A. Introduction/Overview |
F. Eltawila/J. Flack, RES |
8:40 a.m. |
|
|
1. Overview of T/H Research Activities |
|
|
|
|
2. Program Status |
|
|
|
|
|
- Program Accomplishments to Date
- Schedule for Completion
- Canceled/Completed Programs
|
|
|
|
|
3. Relationship of Research Programs to Long-Term Needs |
|
|
|
B. Status of On-Going Research Programs |
J. Uhle/D. Bessette/
C. Boyd, RES |
|
|
|
1. Code Consolidation |
|
|
|
|
2. Code Modeling Research |
|
|
|
|
|
- Flow Regime Modeling/Phase Separation @ Tees/Subcooled Boiling
|
|
|
|
|
3. Experimental Programs |
|
|
|
|
|
- PUMA Test Facilities
- OSU Test Facilities
- Rod Bundle Heat Transfer
|
|
|
|
|
4. CFD Program |
|
|
|
C. Concluding Comments |
F. Eltawila/
J. Flack |
2:45 p.m. |
VI. |
Subcommittee Caucus |
|
3:00 p.m. |
|
- Follow-on Items for this Issue
- Future Actions
- Committee Action
|
|
|
V.
|
Adjourn |
|
3:15 p.m. |