Protecting People and the EnvironmentUNITED STATES NUCLEAR REGULATORY COMMISSION
CR78003
May 5, 1978
MEMORANDUM FOR: B. H. Grier, Director, Region I
J. P. O'Reilly, Director, Region II
J. G. Keppler, Director, Region III
G. Madsen, Acting Director, Region IV
R. H. Engelken, Director, Region V
FROM: Leo B. Higginbotham, Acting Director, FFMSI, IE
SUBJECT: IE CIRCULAR 78-03 PACKAGING GREATER THAN TYPE A
QUANTITIES OF LOW SPECIFIC ACTIVITY RADIOACTIVE
MATERIAL FOR TRANSPORT
The subject document is transmitted for issuance on May 12, 1977. The
Circular should be issued to all holders of Reactor Operating, Licenses and
Construction Permits; and Fuel Cycle, Priority I Materials and Waste
Disposal Licensees. Also enclosed is a draft copy of the transmittal letter.
Leo B. Higginbotham, Acting Director
Division of Fuel Facilities
and Materials Safety Inspection
Office of Inspection and Enforcement
Enclosures:
1. Draft Transmittal Letter
2. Circular 78-03
CONTACT: G. H. Bidinger, IE
49-23188
.
IE Circular 78-03
(Transmitted letter for Circular 78-03 to each holder of an Reactor
Operating License and Construction Permit, and Fuel Cycle, Priority I
Material, and Waste Disposal License)
Addressee:
The enclosed Circular 78-03 is forwarded to you for information. If there
are any questions related to your understanding of the suggested actions,
please contact this office.
Signature
(Regional Director)
Enclosures:
1. IE Circular 78-03
2. List of IE Circulars
Issued in 1978
.
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555
May 12, 1978
IE Circular 78-03
PACKAGING GREATER THAN TYPE A QUANTITIES OF LOW SPECIFIC ACTIVITY
RADIOACTIVE MATERIAL FOR TRANSPORT
This circular describes a situation that has occurred at nuclear power
facilities and that could occur wherever greater than Type A quantities of
low specific activity (LSA) radioactive material are packaged for transport.
Some licensees subject to the requirements of 10 CFR Part 71 have shipped
packages containing greater than Type A quantities of LSA material in
packages which are not authorized by NRC. These unauthorized shipments have
resulted from inadequate understanding of Part 71 regarding LSA material.
Differences between Part 71 and the Department of Transportation
requirements in 49 CFR Parts 170-189 have apparently contributed to these
misunderstandings.
Specifically, 49 CFR 173.392 authorizes the shipment of LSA material in
"strong, tight packages" when transported in vehicles assigned for the sole
use of the consignor. DOT regulations make no mention of the total activity
that may be shipped in this manner. On the other hand, NRC regulations (10
CFR 71.3) require that no licensee shall (a) deliver any licensed materials
to a carrier for transport or (b) transport licensed material except as
authorized in a general or specific license issued by the Commission, or as
exempted in Part 71. The general license of 10 CFR 71.12 has requirements
for the type of container when more than a Type A quantity of radioactive
material is to be transported. LSA material in excess of a Type A quantity
is not exempt from the general license requirements. Several licensees have
failed to recognize the difference in the DOT and NRC requirements and have
packaged greater than Type A quantities of LSA material for transport in
containers other than those authorized by the general license of 10 CFR
71.12.
.
IE Circular 78-03
Compliance with Part 71 is the responsibility of the NRC licensee who
delivers licensed material to a carrier for transport or who transports such
material outside the confines of his plant or other place of use.
No written response to this Circular is required. If you require additional
information regarding this matter, contact the Director of the appropriate
NRC Regional Office.