PRIORITY ATTENTION REQUIRED  MORNING REPORT - REGION IV  NOV. 04, 1999

Licensee/Facility:                     Notification:

Nebraska Public Power District         MR Number: 4-99-0025
Cooper 1                               Date: 11/04/99
Brownville,Nebraska                    Resident Inspectors                
Dockets: 50-298
BWR/GE-4                              

Subject: DROPPED CORE SHROUD BOLT IN SPENT FUEL POOL                     

Discussion:

On November 2, 1999, while operators were removing core shroud bolts from
the spent fuel pool, a cable clamp on the cable supporting one of the    
bolts unfastened.  The approximately 300 lb. bolt dropped 10 feet and hit
a "Tri-Nuke" brand filter canister located on the bottom of the spent    
fuel pool, penetrating the canister and damaging at least one of the     
filters.                                                                 
                                                                         
Licensee personnel performing surveys and water analysis did not detect  
an increase in radioactivity or radiation levels.  They also performed a 
visual inspection of the spent fuel pool liner and found it intact.      
Operators did not detect increased leakage from the spent fuel pool      
tell-tale drains.  The licensee has established a team to investigate the
root cause of the event and evaluate options for removing the bolt from  
the canister.                                                            
                                                                         
During the previous refuleing outage, operators had suspended each of the
shroud bolts from the side of the spent fuel pool by 3/8" steel cables.  
The event occurred as operators moved the bolts for solid radioactive    
waste processing. The movement was conducted in accordance with the      
licensee's heavy loads procedure which contained administrative controls 
to prevent moving the bolts over spent fuel.                             

Regional Action:

Cooper Nuclear Station is a Reactor Inspection Baseline Inspection       
Program Pilot Plant.  The resident inspectors are observing licensee     
actions and evaluating the potential safety significance in accordance   
with the baseline inspection program.                                    

Contact:  Charles S. Marschall       (817)860-8185
          David P. Loveless          (817)860-8161