PRIORITY ATTENTION REQUIRED  MORNING REPORT - REGION III  MAY 23, 2000

Licensee/Facility:                     Notification:

Commonwealth Edison Co.                MR Number: 3-00-0028
Quad Cities 2                          Date: 05/23/00
Cordova,Illinois                       ;VIA E-MAIL                        
Dockets: 50-265
BWR/GE-3                              

Subject: Scram of Unit 2 Due to Steam Pressure Spike and Neutron High    
         Flux                                                            

Reportable Event Number: 37018                         

Discussion:

On May 22, 2000, with Unit 2 at 100 percent of rated power, operators    
were returning the #1 turbine control valve to service. The valve opened 
properly, but at about 50 percent of full open, operators received a high
APRM scram signal. Safety systems associated with response to the scram  
responded properly. However, the Unit 2 emergency diesel generator       
spuriously started and the 2 "A" feedwater regulating valve locked up.   
These conditions did not have an adverse effect on operations, were      
previously identified by the licensee, and will be addressed during      
future system modifications. The licensee believed that as the #1 turbine
control valve opened, the remaining 3 turbine control valves closed in an
unsuccessful attempt to maintain turbine pressure. The resulting steam   
pressure spike caused reactor power to spike to about 113 percent        
resulting in a scram.                                                    
                                                                         
During the transient, an expected low reactor water level produced a     
primary containment isolation signal (Group 2 and Group 3). A second low 
reactor water signal caused another Group 2 and 3 isolation approximately
30 minutes later and was due to slow restoration of a reactor feed pump  
to service.                                                              
                                                                         
The licensee planned to maintain the unit in Mode 3 pending results of   
the root cause investigation into this event and to complete shutdown    
maintenance items.                                                       

Regional Action:

The resident inspector responded to the site and monitored plant recovery
operations.                                                              

Contact:  M. RING                    (630)829-9703
_