PRIORITY ATTENTION REQUIRED  MORNING REPORT - HEADQUARTERS AUGUST 22, 2001

Licensee/Facility:                     Notification:

Part 21 Database                       MR Number: H-01-0058
Indian Point 3                         Date: 08/22/01
                                                                          

Subject: Part 21 - Woodward governor exhibits unstable oscillations      

Discussion:

VENDOR: Engine Systems              PT21 FILE NO: m1-24-0                
                                                                         
DATE OF DOCUMENT: 07/09/01          ACCESSION NUMBER: ML011990032        
                                                                         
SOURCE DOCUMENT: LETTER             REVIEWER: REXB, Y. Diaz              
                                                                         
                                                                         
The Indian Point 3 licensee reports unstable oscillations, between 1,850 
and 1,950 KW, of a Woodward governor during a surveillance test of an    
emergency diesel generator. The governor had worked satisfactorily during
initial start, set up and compression checks at 1,750 KW following the   
eight year preventive maintenance. The licensee had purchased the        
governor, part no. 9903-152, type EGB-13C, serial no. 1165395, from the  
Salem licensee, who had obtained it from Engine Systems.                 
                                                                         
The licensee discovered this failure on May 11, 2001, shortly after      
Engine Systems reported a generic defect in a number of Woodward         
governors worked on by a single individual (see Morning Report H-01-0017 
at http://www.nrc.gov/NRR/DAILY/010308mr.htm), but the governor installed
at Indian Point 3 was not one of the seven identified in that report.    
Troubleshooting did not identify the failure mechanism, so the licensee  
removed the governor and returned it to Engine Systems for further       
evaluation.                                                              
                                                                         
The NRC will post ensuing reports on this subject on its Website at      
http://www.nrc.gov/NRC/PUBLIC/PART21/2001.                               
                                                                         
Contacts:   Y. Diaz, NRR                V. Hodge, NRR                    