Morning Report for December 20, 2006
Headquarters Daily Report
N/A
Tyco Electronics Issued a Notification of Limited E7000 Relay Recall
Licensee/Facility:
MULTIPLE
TYCO ELECTRONICS
Dockets:
License No:
FARELY
Dockets:
OYSTER CREEK
Dockets:
MILLSTONE
Dockets:
NORTH ANNA
Dockets:
SAN ONOFRE
Dockets:
INDIAN POINT
Dockets:
FITZPATRICK
Dockets:
LIMERICK
Dockets:
BRAIDWOOD
Dockets:
PEACH BOTTOM
Dockets:
PERRY
Dockets:
VOGTLE
Dockets:
SUSQUEHANNA
Dockets:
WATTS BAR
Dockets:
PRAIRE ISLAND
Dockets:
DELPHI CONTROLS
Dockets:
ENGINE SYSTEM INC.
Dockets:
ERGY TECHNOLOGY
Dockets:
GE NUCLEAR ENERGY
Dockets:
PROGRESS ENERGY CAROLINAS
Dockets:
|
Notification:
MR Number: H-2006-0019
Date: 12/01/2006
Call / Fax from SRI
|
Discussion:
This morning report is to notify licensees of a Tyco Electronics Relay Issue.
On November 16, 2006, Tyco Electronics notified a number of nuclear power plant customers by letter of a limited E7000 relay recall.
The letter stated, “During Tyco’s normal assembly processing of nuclear E7000 relays, Tyco experienced an issue with a component. A spring in the base assembly broke during the calibration process. An analysis of the spring revealed non-conforming heat treatment causing the spring to become brittle. Further investigation revealed this condition is limited to one specific lot of springs.”
Impacted sites are listed below:
Braidwood Farley FitzPatrick Indian Point
Limerick Millstone North Anna Oyster Creek
Peach Bottom Perry Prairie Island San Onofre
Susquehanna Vogtle Watts Bar
Other impacted vendors:
Curtiss-Wright Flow Control Group Delphi Controls
Engine Systems Inc. Ergy Technology
GE Nuclear Energy
Susquehanna conducted a completed review of the Tyco Electronics "Notification of Limited E7000 Relay Recall (CII-010)". Susquehanna concluded that they received eight relays total. Two relays were installed in "A" & "D" emergency service water (ESW) pump system and five relays were not installed. One relay being held in stock for the plant's emergency diesel generator relay replacement preventive maintenance activity failed a July 6, 2006 pre-installation bench test, and had been sent back to Tyco Electronics for repair or replacement.
After determining that suspect relays were installed on the "A" & "D" ESW pumps, Susquehanna declared the two ESW pumps inoperable. Susquehanna disabled the pumps to ensure the pumps would not start out of sequence during a loss of offsite power and possibly damage the associated diesel generator. Susquehanna bench tested the two ESW pump relays on December 4, 2006 and determined they were operable.
The Susquehanna plant risk was elevated due to the "E" emergency diesel generator out-of-service for overhaul with the two ESW pumps inoperable. Susquehanna had planned to leave the pumps functional (manual start); however, they had limited information on how the failure would affect the timing of the pump start. Subsequently, verbal data was received that concluded the pump would start at the appropriate delayed time or not start at all.
Contacts:
Name |
Office Abbrev |
Phone No |
E-Mail |
GIANTELLI, JOSEPH M |
NRR |
(301) 415-0504 |
JMG8@nrc.gov |
REGION III
Wisconsin Energy Corporation to Sell Point Beach Plant
Licensee/Facility:
NUCLEAR MANAGEMENT CO., LLC
Point Beach 1, Point Beach 2
TWO RIVERS, Wisconsin
Dockets: 05000266, 05000301
[1] W-2-LP, [2] W-2-LP
License No:
|
Notification:
MR Number: 3-2006-0019
Date: 12/20/2006
Resident Inspector
|
Discussion:
On December 20, 2006, Wisconsin Energy Corporation announced that its subsidiary, Wisconsin Electric Power Company, has reached an agreement to sell the Point Beach Nuclear Plant to FPL Energy, a subsidiary of FPL Group, Inc. Under the agreement, FPL will sell 100 percent of the Point Beach output to We Energies, and FPL will offer employment to all current employees at the plant. The purchase price is approximately $1 billion dollars and includes trust funding for facility decommissioning. The transaction is expected to close in August 2007. Transfer of the license still needs to receive various regulatory, including NRC, approval.
Regional Action: For information only; no further action anticipated.
Accession Numbers:
Accession No |
Accession Date |
ML063540174 |
12/20/2006 |
Contacts:
Name |
Office Abbrev |
Phone No |
E-Mail |
LOUDEN, PATRICK L |
R3 |
(630) 829-9627 |
PLL@nrc.gov |
|