skip navigation links 
 
 Search Options 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page

Event Notification Report for July 2, 2003



                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/01/2003 - 07/02/2003

                              ** EVENT NUMBERS **

39631  39970  39971  39972  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39631       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 03/02/2003|
|    UNIT:  [1] [2] []                STATE:  FL |NOTIFICATION TIME: 16:00[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        03/02/2003|
+------------------------------------------------+EVENT TIME:        14:30[EST]|
| NRC NOTIFIED BY:  CHARLES PIKE                 |LAST UPDATE DATE:  07/01/2003|
|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |WALTER RODGERS       R2      |
|10 CFR SECTION:                                 |DAVID AYRES          R2      |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO STATE AGENCY OF EXPIRED GREEN SEA TURTLE FOUND AT    |
| BARRIER NET                                                                  |
|                                                                              |
| "NRC notification [is] being made due to state notification to [the] Florida |
| Wildlife Commission regarding a Green Sea Turtle found dead at barrier net   |
| pursuant to 10 CFR 50.72(b)(2)(xi)."                                         |
|                                                                              |
| The turtle was found on the surface at the barrier net with no injuries or   |
| abnormalities except for fresh cuts common for turtles coming through pipes. |
| The cause of death is unknown at this time. A necropsy is planned.           |
|                                                                              |
| The NRC Resident Inspector will be notified by the licensee.                 |
|                                                                              |
| * * * UPDATE ON 3/15/03 @ 1033 EST FROM TEREZAKIS TO CROUCH * * *            |
|                                                                              |
| "On 3-15-03, a green sea turtle was retrieved from the plant's intake canal. |
| The turtle was determined to be in need of rehabilitation.  The injuries to  |
| the turtle are not causal to plant operation. Per the plant's turtle permit, |
| the Florida Fish and Wildlife Conservation Commission (FWCC) was notified at |
| 0920 EST.  This non-emergency notification is being made pursuant to 10 CFR  |
| 50.72(b)(2)(xi) due to the notification of FWCC."                            |
|                                                                              |
| The NRC Resident Inspector will be notified by the licensee.                 |
|                                                                              |
| * * * UPDATE ON 3/19/03 AT 1222 EST FROM E. SUMNER TO RIPLEY  * * *          |
|                                                                              |
| "On 03/19/03 @ 1105 hrs., one loggerhead turtle was retrieved from the       |
| plant's intake canal.  The turtle was determined to be in need of            |
| rehabilitation.  The injury to the turtle is not causal to plant operation.  |
| Per the plant's turtle permit, the Florida Fish and Wildlife Conservation    |
| Commission (FWCC) was notified at 1115 EST."                                 |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| * * * UPDATED ON 3/31/03 AT 1159 EST FROM W.L. PARK TO A. COSTA * * *        |
|                                                                              |
| "On 3-31-03 [1105 EST], a loggerhead sea turtle was retrieved from the       |
| plant's intake canal. The turtle was determined to be in need of             |
| rehabilitation. The injuries to the turtle are not causal to plant           |
| operation. Per the plant's turtle permit, the Florida Fish and Wildlife      |
| Conservation Commission (FWCC) was notified at 1105 EST. This non-emergency  |
| notification is being made pursuant to 10 CFR 50.72(b)(2)(xi) due to the     |
| notification of FWCC."                                                       |
|                                                                              |
| The NRC Resident Inspector will be notified.                                 |
|                                                                              |
| * * * UPDATE 1235EST ON 4/9/03 FROM ANDY TEREZAKIS TO S.SANDIN * * *         |
|                                                                              |
| "On 4-9-03, a loggerhead sea turtle was retrieved from the plant's Intake    |
| canal. The turtle was determined to be in need of rehabilitation. The        |
| injuries to the turtle are not causal to plant operation. Per the plant's    |
| turtle permit, the Florida Fish and Wildlife Conservation Commission (FWCC)  |
| was notified at 1100 EST. This non-emergency notification is being made      |
| pursuant to 10CFR50.72(b)(2)(xi) due to the notification of FWCC."           |
|                                                                              |
| The licensee informed the NRC resident inspector.  Notified R2DO(Landis).    |
|                                                                              |
| *** UPDATE ON 5/2/03 AT 1826 FROM S. OEHRLE TO A. COSTA ***                  |
|                                                                              |
| "On 5/2/03, a green sea turtle was retrieved from the intake canal.  The     |
| turtle  required rehabilitation.  The injuries were not causal to plant      |
| operation.  Per the plant's turtle permit, the Florida Fish and Wildlife     |
| Conservation Commission was notified at 1445 EDT.  This non-emergency        |
| notification is being made pursuant to 10 CFR 50.72 (b)(2)(xi) due to        |
| offsite notification."                                                       |
|                                                                              |
| The Licensee will notify the NRC Resident Inspector.  Notified R2DO          |
| (Munday).                                                                    |
|                                                                              |
| **** update on 05/24/03 at 1417 EDT FROM JOE HESSLING TO JOHN MACKINNON      |
| ****                                                                         |
|                                                                              |
| "On 5-24-03, a loggerhead sea turtle was retrieved from the plant's intake   |
| canal.  The turtle was determined to be in need of rehabilitation.  The      |
| turtle was very underweight and lethargic, no injuries or anomalies noted.   |
| Turtle's condition is not causal to plant operation.  Per the plant's turtle |
| permit the Florida Fish and Wildlife Conservation Commission (FWCC) was      |
| notified at 1345 EDT.  This non-emergency notification is being made         |
| pursuant to 10 CFR 50.72(b)(2)(xi) due to the notification of FWCC. NRC R2DO |
| (TOM DECKER) notified.                                                       |
|                                                                              |
| The NRC Resident Inspector was by notified of this event by the licensee.    |
|                                                                              |
| ****UPDATE ON 5/27/03 AT 10:49 FROM HESSLING TO LAURA****                    |
|                                                                              |
| "On 5-27-03, a loggerhead sea turtle was retrieved from the plant's intake   |
| canal. The turtle was determined to be in need of rehabilitation. The turtle |
| was underweight, and missing lower posterior marginals on left side.         |
| Turtle's injuries are not causal to plant operation. Per the plant's turtle  |
| permit, the Florida Fish and Wildlife Conservation Commission (FWCC) was     |
| notified at 0850 EDT. This non-emergency notification is being made pursuant |
| to 10 CFR 50.72(b)(2)(xi) due to the notification of FWCC."                  |
|                                                                              |
| Notified R2DO (T. Decker)                                                    |
|                                                                              |
| * * * UPDATE ON 06/17/03 AT 12:45 EDT FROM CALVIN WARD TO ARLON COSTA * * *  |
|                                                                              |
| "At approximately 12:45 p.m. on 6/17/03 a loggerhead turtle was rescued from |
| the St. Lucie Plant intake canal. The turtle was injured and will be         |
| transported to the State authorized sea turtle rehabilitation facility. The  |
| Florida Dept. of Environmental Protection (FDEP) was notified at 1:09 p.m.   |
| as required by the St. Lucie Plant Sea Turtle Permit - see the attached sea  |
| turtle stranding report (1 page).                                            |
|                                                                              |
| "Notification to the state government agency requires a four (4) Hr.         |
| Non-Emergency Notification to the NRC per 10 CFR 50.72(b)(2)(xi). There were |
| no unusual plant evolutions in progress which may have contributed to this   |
| event."                                                                      |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| Notified R2DO (L. Wert).                                                     |
|                                                                              |
| * * * UPDATE 0605 EDT ON 6/26/03 FROM STEVE MERRILL TO S. SANDIN * * *       |
|                                                                              |
| The licensee was informed by the FWCC that the green sea turtle requiring    |
| rehabilitation which was retrieved from the plant's intake canal on 3/15/03  |
| had expired within 10 days of removal.  Consequently, the licensee is        |
| updating their 3/15/03 report to include this additional information.  The   |
| licensee will inform the NRC Resident Inspector.  Notified R2DO(C. Ogle).    |
|                                                                              |
| * * * UPDATE 1506 EDT ON 07/01/03 FROM CALVIN WARD TO GOTT * * *             |
|                                                                              |
| On 04/02/03, a green sea turtle was retrieved from the intake canal.  The    |
| turtle  required rehabilitation.  The injuries were not causal to plant      |
| operation.  Per the plant's turtle permit, the Florida Fish and Wildlife     |
| Conservation Commission was notified.  This non-emergency notification is    |
| being made pursuant to 10 CFR 50.72 (b)(2)(xi) due to offsite notification.  |
| On 07/01/03 licensee QA discovered that the injury had occurred and that the |
| NRC had not been notified within the 4 hours.  The failure to report the     |
| event within the regulatory time is being investigated and has been entered  |
| into the stations corrective action program.                                 |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| Notified R2DO (Munday)                                                       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39970       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 07/01/2003|
|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 00:04[EDT]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        06/30/2003|
+------------------------------------------------+EVENT TIME:        15:45[CDT]|
| NRC NOTIFIED BY:  DAVID BARNETT                |LAST UPDATE DATE:  07/01/2003|
|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRENT CLAYTON        R3      |
|10 CFR SECTION:                                 |                             |
|AINA 50.72(b)(3)(v)(A)   POT UNABLE TO SAFE SD  |                             |
|AINB 50.72(b)(3)(v)(B)   POT RHR INOP           |                             |
|AINC 50.72(b)(3)(v)(C)   POT UNCNTRL RAD REL    |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HIGH ENERGY LINE BREAK (HELB) DOOR NOT LATCHED                               |
|                                                                              |
| "On June 30, 2003 at approximately 1545 [CDT] it was identified that a High  |
| Energy Line Break (HELB) door separating Divisional Motor Control Centers    |
| was not latched as required.  It was determined that this condition existed  |
| for a maximum of 15 minutes.  This condition is being reported as an event   |
| or condition that could have prevented the fulfillment of a safety function  |
| in accordance with 10 CFR 50.72(b)(3)(v)."                                   |
|                                                                              |
| The licensee notified the NRC Resident Inspector and the State Emergency     |
| Management Agency.                                                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39971       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LASALLE                  REGION:  3  |NOTIFICATION DATE: 07/01/2003|
|    UNIT:  [1] [2] []                STATE:  IL |NOTIFICATION TIME: 12:13[EDT]|
|   RXTYPE: [1] GE-5,[2] GE-5                    |EVENT DATE:        07/01/2003|
+------------------------------------------------+EVENT TIME:        08:00[CDT]|
| NRC NOTIFIED BY:  JOHN WASHKO                  |LAST UPDATE DATE:  07/01/2003|
|  HQ OPS OFFICER:  BILL GOTT                    +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRENT CLAYTON        R3      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PRESS RELEASE DUE TO SIREN MALFUNCTION                                       |
|                                                                              |
| The licensee provided the following information via facsimile:               |
|                                                                              |
| "At approximately 0800 (CDT) on July 1, 2003, LaSalle County Station         |
| management decided to issue a press release related to a single              |
| malfunctioned warning siren.  The warning siren had malfunctioned and        |
| erroneously operated for nearly 90 minutes early this morning.  LaSalle      |
| County Generating Station will begin replacing the faulty warning siren's    |
| electronics today.  The press release is tentatively expected to occur today |
| at 1130 CDT.  No other emergency notification systems or sirens              |
| malfunctioned.                                                               |
|                                                                              |
| "The siren, located in LaSalle County on East 25th Road approximately        |
| one-half mile west of the station, is currently out of service.  It is       |
| expected to return to service on Wednesday July 2."                          |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39972       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEQUOYAH                 REGION:  2  |NOTIFICATION DATE: 07/02/2003|
|    UNIT:  [1] [2] []                STATE:  TN |NOTIFICATION TIME: 00:17[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        07/01/2003|
+------------------------------------------------+EVENT TIME:        18:45[EDT]|
| NRC NOTIFIED BY:  KEN STEVENS                  |LAST UPDATE DATE:  07/02/2003|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JOEL MUNDAY          R2      |
|10 CFR SECTION:                                 |HAROLD CHRISTENSEN   R2      |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |ROBERTA WARREN       TAS     |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNACCOUNTED FOR SECURITY WEAPON                                              |
|                                                                              |
| Unaccounted for security weapon. Immediate compensatory measures taken upon  |
| discovery.  TVA security and NRC Resident Inspector notified.  Refer to HOO  |
| Log for additional details.                                                  |
|                                                                              |
| * * * UPDATE ON 07/02/03 AT 0150 FROM HERBERT EAVES TO ARLON COSTA * * *     |
|                                                                              |
| TVA Police made offsite notification on 07/01/03 at 2300 EDT to the National |
| Crime Information Center pertaining to the unaccounted for security weapon.  |
| The NRC Resident Inspector will be notified of this event update.            |
+------------------------------------------------------------------------------+