December 11, 2000
NRC INFORMATION NOTICE 2000-20: | POTENTIAL LOSS OF REDUNDANT SAFETY- RELATED EQUIPMENT BECAUSE OF THE LACK OF HIGH-ENERGY LINE BREAK BARRIERS |
All holders of operating licenses or construction permits for nuclear power reactors.
The U.S. Nuclear Regulatory Commission (NRC) is issuing this information notice to alert addressees to the discovery of several high-energy line break (HELB) concerns about redundant safety-related equipment at D. C. Cook Nuclear Plant, Units 1 and 2. A failure of redundant safety-related equipment may result in risk-significant configurations. It is expected that the recipients will review the information for applicability to their facilities and consider corrective actions, as appropriate. However, suggestions contained in this information notice are not NRC requirements; therefore, no specific action or written response is required.
As a result of the numerous safety issues identified at Cook 1 and 2 since August 1997, the NRC analyzed the risk significance of Cook issues using the Accident Sequence Precursor (ASP) program methodology. Of the 141 issues analyzed, four were found to be accident sequence precursors since their conditional core damage frequencies were greater than 1.0×10-6/year. Two of these four issues involved postulated HELB scenarios that may lead to failure of redundant safety-related systems (see Licensee Event Reports (LERs) 316/98-005 and 315/99-026 for details).
Within these two issues there are three scenarios that are described below:
Four conditions must coexist to produce a risk-significant configuration like that at Cook. These four conditions are (1) lack of a HELB barrier between the redundant trains of a system that is needed to mitigate accidents, (2) the lack of environmental qualification for the redundant components of trains located in the same area, (3) the presence of high-energy piping in adjacent areas, and (4) the lack of a HELB barrier between adjacent piping and the redundant safety system trains.
Section 3.6.1 of the Standard Review Plan (SRP) and NRR Plant Systems Branch Technical Position SPLB 3-1 (formerly APCSB 3-1) provide regulatory guidance on the plant design for protection against postulated piping failures outside containment. When SPLB 3-1 is used as a guide to meet the requirements of the General Design Criterion 4 of 10 CFR Part 50, Appendix A, the method used to conform with that regulatory guidance depends upon when the construction permit applications were tendered and the operating licenses issued. Section B.4 of SPLB 3-1 provides details on the dependence of its applicability to the dates on which construction permits were tendered or operating licenses were issued.
Generic Letter 87-11, issued on June 11, 1987, transmitted Revision 2 of the Mechanical Engineering Branch (MEB) Technical Position MEB 3-1. This revision provided additional guidance on locations where pipe breaks should be postulated. Revision 2 of MEB 3-1 allows the elimination of pipe-whip restraints, jet-impingement shields (placed to mitigate the effects of arbitrary intermediate ruptures), and other related changes. However, the revision does not relieve licensees from the need to conform to the guidance relating to HELB effects on essential systems and components. Essential systems and components are systems and components required to shut down the reactor and mitigate the consequences of a postulated piping failure, without offsite power. Even though application of Revision 2 of the MEB 3-1 pipe break criteria may not require postulating breaks near areas that house the redundant equipment and installing pipe restraints, licensees are expected to comply with their licensing basis and regulatory commitments for postulating a crack at the location most damaging to the essential structures and systems. For example, the Giambusso letter of 1972 (NUREG-0800, Standard Review Plan 3.16.1, Appendix B, Rev. 2, October 1999) specifies that where pipes carrying high-energy fluids are routed near structures and systems necessary for safe shutdown of the plant, supplemental protection of those structures and systems shall be provided to cope with the environmental effects (including the effects of jet-impingement) of a single postulated open crack at the location most damaging to those essential structures and systems.
NUREG-1728, "Assessment of Risk Significance Associated With Issues Identified at D. C. Cook Nuclear Power Plant," Volumes 1 & 2 were published in October 2000. This report documents the results of an analysis of the risk significance at D. C. Cook Nuclear Power Plant, Units 1 & 2 since August 1997. This NUREG may be accessed electronically at the NRC's Public Electronic Reading Room at www.nrc.gov/NRC/ADAMS/index.html.
This information notice requires no specific action or written response. If you have any questions about the information in this notice, please contact one of the technical contacts listed below, the appropriate regional office, or the appropriate Office of Nuclear Reactor Regulation (NRR) project manager.