Information Notice No. 82-44: CLARIFICATION OF EMERGENCY PLAN EXERCISE
REQUIREMENTS
Addressee:
All nuclear power reactor facilities holding an operating license (OL) or
construction permit (CP).
Purpose:
This information notice is provided to clarify certain exercise requirements
contained in the emergency planning rule. It is expected that recipients
will review the information for applicability to their facilities. No
specific action or response is required.
Discussion:
The Statement of Consideration contained in the Federal Register Notice of
the Emergency Planning, Final Regulations (45 FR 55408, August 19, 1980)
stated:
On an annual basis, all commercial nuclear power facilities will be
required by NRC to exercise their plans; these exercises should involve
exercising the appropriate local government plans in support of these
facilities. The State may choose to limit its participation in
exercises at facilities other than the facility (site) chosen for the
annual exercise(s) of the State plan.
and
Each State and appropriate local government shall annually conduct an
exercise jointly with a commercial nuclear power facility.
To carry out this intent, the emergency planning regulations contained in 10
CFR 50, Appendix E, Section IV.F, state in part:
A full-scale exercise which tests as much of the licensee, State, and
local emergency plans as is reasonably achievable without mandatory
public participation shall be conducted:
a. For each site at which one or more power reactors are located and
licensed for operation,... at a frequency which will enable each
State and local government within the plume exposure pathway EPZ
to participate in at least one full-scale exercise per year....
At some facilities this requirement has been interpreted to mean that when a
State does not fully participate in an exercise, because of previous or
planned full participation at another site that year, the licensee or local
government
8208190251
.
IN 82-44
November 18, 1982
Page 2 of 2
need not fully participate. This is not the case. The regulations require
that each facility, State, and local government participate fully in the
exercise of their emergency plans each year. Less than full participation by
a State or local government during a facility's exercise is acceptable only
when the State or local government is participating fully with another
facility that year. Full participation involves testing as much of the
emergency plan as is reasonably achievable without mandatory public
participation. Whenever less than full participation by offsite authorities
is appropriate, that participation shall be small scale as defined in 10 CFR
50, Appendix E, Section IV.F.3.
Therefore, when a local government or State is affected by only one site,
that local government or State would need to participate fully in the annual
emergency planning exercise at that site. When a local government is
affected by only one site and the appropriate State is affected by more than
that one site, the local government would need to participate fully in the
annual emergency planning exercise at that site even if the State is
participating on a small scale at that site that year. At least once every
five years, the full-scale exercise for every facility must include full
participation by the State and local governments. Where full participation
of an organization (i.e., local government) is restricted by the lack of
participation of another organization (i.e., State), the actions of the
other organization should be simulated sufficiently for the exercise
objectives to be met. With the exception of these simulated actions, it is
not expected that a local government will perform any function that it would
not normally be responsible for if the State were fully participating.
Simulation of licensee activity would not be appropriate, as the licensee
must exercise its plan on an annual basis.
Questions have also been raised on the leeway allowed with respect to the
annual exercise frequency requirements. An average of one exercise per year
must be maintained, as called for by the Commission's regulations. It is
unlikely that the Commission would take enforcement action if the annual
exercise is held within three months of the anniversary of the previous
annual exercise.
No written response to the Information Notice is required. If you need
additional information regarding this matter, please contact the Regional
Administrator of the appropriate NRC Regional Office or this office.