skip navigation links 
 
 Search Options 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page
Information Notices
2008
2007
2006
2005
2004
2003
2002
2001
2000
1999
1998
1997
1996
1995
1994
1993
1992
1991
1990
1989
1988
1987
1986
1985
1984
1983
1982
1981
1980
1979

Information Notices - 2006

The following links on this page are to documents in Adobe Portable Document Format (PDF). See our Plugins, Viewers, and Other Tools page for more information. For successful viewing of PDF documents on our site please be sure to use the latest version of Adobe.

File Name Date Description
in200631 12/26/06 Inadequate Fault Interrupting Rating of Breakers
in200630 12/21/06 Summary of Fitness-for-duty Program Performance Reports for Calendar Years 2004 and 2005
in200629 12/14/06 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem nut Wear
in200628 12/22/06 Siren System Failures Due to Erroneous Siren System Signal
in200627 12/11/06 Circumferential Cracking in the Stainless Steel Pressurizer Heater Sleeves of Pressurized Water Reactors
in200626 11/20/06 Failure of Magnesium Rotors in Motor-operated Valve Actuators
in200625 11/14/06 Lessons Learned From NRC Inspection Of Control And Accounting Of Special Nuclear Material At Commercial Nuclear Power Reactors
in200624 11/14/06 Recent Operating Experience Associated with Pressure and Main Steam Safety/Relief Valve Lift Setpoints
in200623 11/07/06 Events Involving Potential Tampering Or Malfeasance By Persons Granted Unescorted Access
in200622 10/12/06 New Ultra-low-sulfur Diesel Fuel Oil Could Adversely Impact Diesel Engine Performance
in200621 09/21/06 Operating Experience Regarding Entrainment of Air into Emergency Core Cooling and Containment Spray Systems
in200620 10/16/06 Foreign Material Found in the Emergency Core Cooling System
in200619 08/24/06 Leaking Fuel Element Causes False Indication of Steam Dryer Leakage in Boiling-Water Reactor
in200618sup1 08/10/07 Significant Loss of Safety-Related Electrical Power at Forsmark, Unit 1, in Sweden
in200618 08/17/06 Significant Loss of Safety-Related Electrical Power at Forsmark, Unit 1, in Sweden
in200617 07/31/06 Recent Operating Experience of Service Water Systems Due to External Conditions
in200616 07/28/06 Implementing Search Requirements for Personnel, Packages and Material at NRC-Licensed Facilities
in200615 07/27/06 Vibration-Induced Degradtion and Failure of Safety-Related Valves
in200614sup1 09/25/06 Potentially Defective External Lead-Wire Connections in Barton Pressure Transmitters
in200614 07/10/06 Potentially Defective External Lead-Wire Connections in Barton Pressure Transmitters
in200613 07/10/06 Ground-Water Contamination Due to Undetected Leakage of Radioactive Water
in200612 07/06/06 Exercising Due Diligence when Transferring Radioactive Materials
in200611 06/12/06 Applicability of Patient Intervention in Determining Medical Events for Gamma Stereotactic Radiosurgery and Other Therapy Procedures
in200610 04/23/06 Use of Concentration Control for Criticality Safety
in200609 04/11/06 Performance of NRC-Licensed Individuals while on Duty with Respect to Control Room Attentiveness
in200608 03/16/06 Secondary Piping Rupture at the Mihama Power Station in Japan
in200607 03/31/06 Inappropriate Use of a Single-Parameter Limit as a Nuclear Criticality Safety Limit
in200606 03/03/06 Loss of Offsite Power and Station Blackout Are More Probable During Summer Period
in200605 03/03/06 Possible Defect in Bussmann KWN-R AND KTN-R Fuses
in200604 02/13/06 Design Deficiency in Pressurizer Heaters for Pressurized-Water Reactors
in200603 01/25/06 Motor Starter Failures Due to Mechanical-Interlock Binding
in200602 01/19/06 Use of Galvanized Supports and Cable Trays with Meggitt Si 2400 Stainless-Steel-Jacketed Electrical Cables
in200601 01/12/06 Torus Cracking in a BWR Mark I Containment


Privacy Policy | Site Disclaimer
Friday, August 24, 2007