skip navigation links 
 
 Search Options 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page
Information Notices
2008
2007
2006
2005
2004
2003
2002
2001
2000
1999
1998
1997
1996
1995
1994
1993
1992
1991
1990
1989
1988
1987
1986
1985
1984
1983
1982
1981
1980
1979

Information Notices - 1990

File Name Date Description
in90068s1 04/14/1994 Stress Corrosion Cracking of Reactor Coolant Pump Bolts
in90057s1 11/27/1991 Substandard, Refurbished Potter & Brumfield Relays Represented as New
in90051s1 10/24/1991 Failures of Voltage-Dropping Resistors in the Power Supply Circuitry of Electric Governor Systems
in90043s1 03/13/1991 Mechanical Interference with Thermal Trip Function in GE Molded-Case Circuit Breakers
in90025s1 03/11/1991 Loss of Vital AC Power with Subsequent Reactor Coolant System Heat-Up
in90077s1 02/04/1991 Inadvertent Removal of Fuel Assemblies from the Reactor Core
in90082 12/31/1990 Requirements for Use of NRC-Approved Packages for Shipment of Type A Quantities of Radioactive Material
in90081 12/24/1990 Fitness for Duty
in90080 12/21/1990 Sand Intrusion Resulting in Two Diesel Generators Becoming Inoperable
in90079 12/20/1990 Failures of Main Steam Isolation Check Valves Resulting in Disc Separation
in90078 12/18/1990 Previously Unidentified Release Path from Boiling Water Reactor Control Rod Hydraulic Units
in90077 12/12/1990 Inadvertent Removal of Fuel Assemblies from the Reactor Core
in90076 12/07/1990 Failure of Turbine Overspeed Trip Mechanism Because of Inadequate Spring Tension
in90075 12/05/1990 Denial of Access to Current Low-Level Radioactive Waste Disposal Facilities
in90074 12/04/1990 Information on Precursors to Severe Accidents
in90073 11/29/1990 Corrosion of Valve-to-Torque Tube Keys in Spray Pond Cross Connect Valves
in90072 11/28/1990 Testing of Parallel Disc Gate Valves in Europe
in90071 11/06/1990 Effective Use of Radiation Safety Committees to Exercise Control over Medical Use Programs
in90038s1 11/06/1990 License and Fee Requirements for Processing Financial Assurance Submittals for Decommissioning
in90070 11/06/1990 Pump Explosions Involving Ammonium Nitrate
in90069 10/31/1990 Adequacy of Emergency and Essential Lighting
in90068 10/30/1990 Stress Corrosion Cracking of Reactor Coolant Pump Bolts
in90067 10/29/1990 Potential Security Equipment Weaknesses
in90066 10/25/1990 Incomplete Draining and Drying of Shipping Casks
in90065 10/05/1990 Recent Orifice Plate Problems
in90064 10/04/1990 Potential for Common-Mode Failure of HPSI Pumps or Release of Reactor Coolant Outside Containment During a LOCA
in90063 10/03/1990 Management Attention to the Establishment and Maintenance of a Nuclear Criticality Safety Program
in90062 09/25/1990 Requirements for Import and Distribution of Neutron-Irradiated Gems
in90061 09/20/1990 Potential for Residual Heat Removal Pump Damage Caused by Parallel Pump Interaction
in90060 09/20/1990 Availability of Failure Data in the Government-Industry Data Exchange Program
in90059 09/17/1990 Errors in the Use of Radioactive Iodine-131
in90058 09/11/1990 Improper Handling of Ophthalmic Strontium-90 Beta Radiation Applicators
in90057 09/05/1990 Substandard, Refurbished Potter & Brumfield Relays Misrepresented as New
in90056 09/04/1990 Inadvertent Shipment of a Radioactive Source in a Container Thought to Be Empty
in90055 08/31/1990 Recent Operating Experience on Loss of Reactor Coolant Inventory While in a Shutdown Condition
in90054 08/28/1990 Summary of Requalification Program Deficiencies
in90053 08/16/1990 Potential Failures of Auxiliary Steam Piping and the Possible Effects on the Operability of Vital Equipment
in90052 08/14/1990 Retention of Broken Charpy Specimens
in90051 08/08/1990 Failures of Voltage-Dropping Resistors in the Power Supply Circuitry of Electric Governor Systems
in90050 08/08/1990 Minimization of Methane Gas in Plant Systems and Radwaste Shipping Containers
in90049 08/06/1990 Stress Corrosion Cracking in PWR Steam Generator Tubes
in90048 08/02/1990 Enforcement Policy for Hot Particle Exposures
in90047 07/27/1990 Unplanned Radiation Exposures to Personnel Extremities Due to Improper Handling of Potentially Highly Radioactive Source
in90046 07/16/1990 Criminal Prosecution of Wrongdoing Committed by Suppliers of Molded-Case Circuit Breakers and Related Components
in90045 07/06/1990 Overspeed of the Turbine-Driven Auxiliary Feedwater Pumps and Overpressurization of the Associated Piping System
in90044 06/29/1990 Dose-Rate Instruments Underresponding to the True Radiation Fields
in90043 06/29/1990 Mechanical Interference with Thermal Trip Function in GE Molded-Case Circuit Breakers
in90042 06/19/1990 Failure of Electrical Power Equipment Due to Solar Magnetic Disturbances
in90032s1 06/19/1990 Surface Crack and Subsurface Indications in the Weld of a Reactor Vessel Head
in90041 06/12/1990 Potential Failure of General Electric Magne-Blast Circuit Breakers and AK Circuit Breakers
in90040 06/05/1990 Results of NRC-Sponsored Testing of Motor-Operated Valves
in90039 06/01/1990 Recent Problems with Service Water Systems
in90038 05/29/1990 Requirements for Processing Financial Assurance Submittals for Decommissioning
in90037 05/24/1990 Sheared Pinion Gear-to-Shaft Keys in Limitorque Motor Actuators
in90036 05/24/1990 Apparent Falsification of State of Connecticut Weight Certificates
in90035 05/24/1990 Transportation of Type A Quantities of Non-Fissile Radioactive Materials
in90034 05/10/1990 Response to False Siren Activations
in90033 05/09/1990 Sources of Unexpected Occupational Radiation Exposures at Spent Fuel Storage Pools
in90032 05/03/1990 Surface Crack and Subsurface Indications in the Weld of a Reactor Vessel Head
in90031 05/04/1990 Update on Waste Form and High Integrity Container ... Review Status, Identification of Problems with Cement Solidification ... Waste Mishaps
in90030 05/01/1990 Ultrasonic Inspection Techniques for Dissimilar Metal Welds
in90029 04/30/1990 Cracking of Cladding and its Heat-Affected Zone in the Base Metal of a Reactor Vessel Head
in90028 04/30/1990 Potential Error in High Steamline Flow Setpoint
in90027 04/30/1990 Clarification of ... Regulatory Requirements for Packaging of Uranium Hexafluoride (UF6) for Transportation
in90026 04/24/1990 Inadequate Flow of Essential Service Water to Room Coolers and Heat Exchangers for Engineered Safety-Feature Systems
in90025 04/16/1990 Loss of Vital AC Power with Subsequent Reactor Coolant System Heat-Up
in90024 04/10/1990 Transportation of Model SPEC 2-T Radiographic Exposure Device
in90023 04/04/1990 Improper Installation of Patel Conduit Seals
in90022 03/23/1990 Unanticipated Equipment Actuations Following Restoration of Power to Rosemount Transmitter Trip Units
in90020 03/22/1990 Personnel Injuries Resulting from Improper Operation of Radwaste Incinerators
in90021 03/22/1990 Potential Failure of Motor-Operated Butterfly Valves to Operate Because Valve Seat Friction Was Underestimated
in90019 03/14/1990 Potential Loss of Effective Volume for Containment Recirculation Spray at PWR Facilities
in90018 03/09/1990 Potential Problems with Crosby Safety Relief Valves Used on Diesel Generator Air Start Receiver Tanks
in90017 03/08/1990 Weight and Center of Gravity Discrepancies for Copes-Vulcan Valves
in90016 03/07/1990 Compliance with New Decommissioning Rule
in90015 03/07/1990 Reciprocity: Notification of Agreement State Radiation Control Directors Before Beginning Work in Agreement States
in90014 03/06/1990 Accidental Disposal of Radioactive Materials
in90013 03/05/1990 Importance of Review and Analysis of Safeguards Event Logs
in90012 02/28/1990 Monitoring or Interruption of Plant Communications
in90011 02/23/1990 Maintenance Deficiency Associated with Solenoid-Operated Valves
in90010 02/23/1990 Primary Water Stress Corrosion Cracking (PWSCC) of Inconel 600
in90009 02/05/1990 Extended Interim Storage of Low-Level Radioactive Waste by Fuel Cycle and Materials Licensees
in90008 02/01/1990 KR-85 Hazards from Decayed Fuel
in90007 01/30/1990 New Information Regarding Insulation Material Performance and Debris Blockage of PWR Containment Sumps
in90006 01/29/1990 Potential for Loss of Shutdown Cooling While at Low Reactor Coolant Levels
in90005 01/29/1990 Inter-System Discharge of Reactor Coolant
in90004 01/26/1990 Cracking of the Upper Shell-to-Transition Cone Girth Welds in Steam Generators
in90003 01/23/1990 Malfunction of Borg-Warner Bolted Bonnet Check Valves Caused by Failure of the Swing Arm
in90002 01/22/1990 Potential Degradation of Secondary Containment
in90001 01/12/1990 Importance of Proper Response to Self-Identified Violations by Licensees


Privacy Policy | Site Disclaimer
Monday, February 19, 2007