Protecting People and the EnvironmentUNITED STATES NUCLEAR REGULATORY COMMISSION
SSINS No.: 6835
IN 83-60
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555
September 22, 1983
Information Notice No. 83-60: FALSIFICATION OF TEST RESULTS FOR
PROTECTIVE COATINGS
Addressees:
All holders of a nuclear power reactor operating license (OL) or
construction permit (CP), and nuclear fuel cycle licensees.
Purpose:
This information notice is provided as a notification of a potentially
significant problem pertaining to the alteration of a test report and
subsequent use of substandard materials at a nuclear facility.
Earlier this year, a jury found the Quality Assurance Director of a
protective coatings company guilty of fraudulent practices. Although the
fraudulent practices occurred in 1979 and 1980, the criminal trial was not
concluded until March 25, 1983. Nuclear power reactor licensees who had
purchased protective coatings from this company during the period of concern
were notified at the time. Presently, the details of this case are being
publicized to illustrate the risk involved in accepting test reports that
are not provided directly from an independent testing facility.
It is expected that addressees of this information notice will review the
general problem described herein for applicability to their facilities. No
specific action or response is required.
Description of Circumstances:
In early 1979, Con-Chem, Incorporated (CCI) sought a contract to supply a
protective coating for use at the Hope Creek Generating Station. The
architectural engineering firm for the Hope Creek project was Bechtel
Corporation of San Francisco. To qualify for consideration, bidders were
required to demonstrate that the coatings would withstand accident-level
radiation exposures. Pursuant to this requirement, CCI submitted concrete
test blocks coated with their product to Oak Ridge National Laboratory
(ORNL) for radiation tests. Following receipt of an acceptable test report
and confirming photographs
8308300330
.
IN 83-60
September 22, 1983
Page 2 of 2
of the test blocks, Bechtel awarded the contract to CCI and the protective
coating was applied to selected areas within containment at the Hope Creek
Generating Station.
Later, an FBI investigation determined that the Quality Assurance Director
for CCI had altered the ORNL test report before-delivering it to Bechtel.
The report provided to Bechtel by the Quality Assurance Director stated
"coating intact, no defects" whereas a copy of the report on file at ORNL
indicated "delamination," "cracking," and "peeling" of the coating following
the radiation exposure tests. Additionally, it was discovered that the
photographs of the test blocks actually showed untested blocks which had
been spray painted brown by the Quality Assurance Director to make them
appear radiation tested. The protective coating used at Hope Creek had to be
removed and replaced. The investigation did not uncover any illegal or
fraudulent activity on the part of any other company official.
On March 25, 1983, a jury found the Quality Assurance Director guilty and he
was later sentenced to three years' confinement and fined $6,000.
In this case and perhaps others, it appears the problem and associated cost
and schedule-related impact could have been averted by requiring that the
test report or a copy thereof be submitted directly from the reputable
testing facility.
If you have any questions regarding this matter, please contact the Regional
Administrator of the appropriate NRC Regional Office, or this office.
Edward L. Jordan, Director
Division of Emergency Preparedness
and Engineering Response
Office of Inspection and Enforcement
Technical Contact: R. M. Young, IE
49-27275
Attachment:
List of Recently Issued IE Information Notices
.