Search Options | ||||
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us |
Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned scrams | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 2208.0 | 2209.0 | 1801.6 | 1740.3 | 2208.0 | 2209.0 | 2183.0 | 2184.0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned power changes | 0 | 0 | 0 | 1.0 | 2.0 | 0 | 0 | 0 |
Critical hours | 2208.0 | 2209.0 | 1801.6 | 1740.3 | 2208.0 | 2209.0 | 2183.0 | 2184.0 |
Indicator value | 0.8 | 0.8 | 0.8 | 0.9 | 2.6 | 2.6 | 2.5 | 1.6 |
Licensee Comments: none
Unplanned Scrams with Complications | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (BWR) | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Safety System Functional Failures | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 2.20E-07 | 4.40E-08 | 4.40E-08 | 4.50E-08 | 4.50E-08 | 4.50E-08 | 3.70E-08 | -3.00E-09 |
URI (ΔCDF) | -5.80E-07 | -7.90E-08 | -9.10E-08 | -8.80E-08 | -8.80E-08 | -8.60E-08 | -2.10E-07 | -2.10E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -3.60E-07 | -3.50E-08 | -4.70E-08 | -4.30E-08 | -4.30E-08 | -4.10E-08 | -1.73E-07 | -2.13E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, High Pressure Injection System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -3.90E-08 | -4.10E-08 | -4.10E-08 | -5.20E-08 | -5.20E-08 | -5.20E-08 | -5.20E-08 | -5.30E-08 |
URI (ΔCDF) | 1.30E-07 | 6.60E-08 | 6.90E-08 | -1.70E-08 | -1.70E-08 | -1.70E-08 | -1.60E-08 | -1.40E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 9.10E-08 | 2.50E-08 | 2.80E-08 | -6.90E-08 | -6.90E-08 | -6.90E-08 | -6.80E-08 | -6.70E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -4.10E-08 | -2.50E-08 | -2.40E-08 | -2.40E-08 | -3.70E-08 | -3.00E-08 | -2.50E-09 | -4.20E-09 |
URI (ΔCDF) | -2.10E-08 | -1.20E-08 | -1.30E-08 | -1.30E-08 | -1.30E-08 | -1.30E-08 | -1.30E-08 | -1.20E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -6.20E-08 | -3.70E-08 | -3.70E-08 | -3.70E-08 | -5.00E-08 | -4.30E-08 | -1.55E-08 | -1.62E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Residual Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -7.40E-08 | -3.50E-08 | -3.50E-08 | -3.50E-08 | -3.50E-08 | -3.50E-08 | -3.50E-08 | -3.50E-08 |
URI (ΔCDF) | -1.30E-08 | -8.30E-09 | -8.90E-09 | -8.80E-09 | -8.70E-09 | -8.70E-09 | -8.90E-09 | -7.70E-09 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -8.70E-08 | -4.33E-08 | -4.39E-08 | -4.38E-08 | -4.37E-08 | -4.37E-08 | -4.39E-08 | -4.27E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Cooling Water Systems | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -1.30E-07 | -7.20E-08 | 6.30E-09 | -5.80E-09 | -6.30E-09 | -6.30E-09 | -2.00E-08 | -2.30E-08 |
URI (ΔCDF) | 6.90E-08 | 5.20E-08 | 4.80E-08 | -3.70E-08 | -3.70E-08 | -3.70E-08 | -3.70E-08 | -3.50E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -6.10E-08 | -2.00E-08 | 5.43E-08 | -4.28E-08 | -4.33E-08 | -4.33E-08 | -5.70E-08 | -5.80E-08 |
Licensee Comments: none
Reactor Coolant System Activity | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum activity | 0.000067 | 0.000068 | 0.000071 | 0.000049 | 0.000065 | 0.000224 | 0.000117 | 0.000152 | 0.000080 | 0.000138 | 0.000069 | 0.000067 |
Technical specification limit | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Reactor Coolant System Activity | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum activity | 0.000053 | 0.000080 | 0.000147 | 0.000179 | 0.000156 | 0.000161 | 0.000172 | 0.000124 | 0.000177 | 0.000199 | 0.000012 | 0.000008 |
Technical specification limit | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments:
6/08: In accordance with Technical Specification Amendment 194, beginning in May 2008 Nine Mile Point Unit 1 is reporting this indicator as Dose Equivalent Iodine.
Reactor Coolant System Leakage | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum leakage | 5.100 | 4.850 | 4.900 | 4.950 | 5.000 | 4.900 | 4.800 | 4.800 | 5.000 | 5.200 | 5.200 | 4.850 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 20.4 | 19.4 | 19.6 | 19.8 | 20.0 | 19.6 | 19.2 | 19.2 | 20.0 | 20.8 | 20.8 | 19.4 |
Reactor Coolant System Leakage | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum leakage | 4.750 | 4.800 | 5.100 | 4.750 | 4.800 | 5.000 | 4.700 | 4.700 | 4.700 | 4.750 | 4.800 | 4.800 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 19.0 | 19.2 | 20.4 | 19.0 | 19.2 | 20.0 | 18.8 | 18.8 | 18.8 | 19.0 | 19.2 | 19.2 |
Licensee Comments: none
Drill/Exercise Performance | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful opportunities | 129.0 | 109.0 | 41.0 | 27.0 | 35.0 | 318.0 | 31.0 | 38.0 |
Total opportunities | 138.0 | 113.0 | 43.0 | 30.0 | 39.0 | 318.0 | 34.0 | 40.0 |
Indicator value | 94.6% | 95.1% | 95.1% | 95.0% | 94.4% | 96.8% | 96.6% | 96.4% |
Licensee Comments: none
ERO Drill Participation | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Participating Key personnel | 93.0 | 84.0 | 97.0 | 97.0 | 94.0 | 93.0 | 90.0 | 91.0 |
Total Key personnel | 94.0 | 89.0 | 97.0 | 97.0 | 95.0 | 93.0 | 90.0 | 91.0 |
Indicator value | 98.9% | 94.4% | 100.0% | 100.0% | 98.9% | 100.0% | 100.0% | 100.0% |
Licensee Comments: none
Alert & Notification System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful siren-tests | 294 | 295 | 296 | 221 | 296 | 257 | 296 | 222 |
Total sirens-tests | 296 | 296 | 296 | 222 | 296 | 259 | 296 | 222 |
Indicator value | 99.7% | 99.6% | 99.6% | 99.6% | 99.8% | 99.7% | 99.7% | 99.8% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Action Matrix Summary | Inspection Findings Summary | PI Summary | Reactor Oversight Process
Last Modified: August 4, 2008