Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned scrams | 0 | 0 | 0 | 0 | 0 | 0 | 1.0 | 0 |
Critical hours | 2208.0 | 2209.0 | 2159.0 | 2184.0 | 2208.0 | 2209.0 | 1693.6 | 2184.0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0.8 | 0.8 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned power changes | 0 | 0 | 0 | 0 | 1.0 | 0 | 0 | 0 |
Critical hours | 2208.0 | 2209.0 | 2159.0 | 2184.0 | 2208.0 | 2209.0 | 1693.6 | 2184.0 |
Indicator value | 0.8 | 0 | 0 | 0 | 0.8 | 0.8 | 0.8 | 0.8 |
Licensee Comments: none
Unplanned Scrams with Complications | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (BWR) | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Safety System Functional Failures | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 1 | 1 | 1 | 1 | 0 | 0 | 0 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -1.50E-09 | -1.10E-09 | -2.00E-09 | -2.60E-09 | -2.60E-09 | -2.50E-09 | -8.90E-09 | -5.60E-09 |
URI (ΔCDF) | -3.20E-07 | -3.20E-07 | -3.20E-07 | -3.20E-07 | -2.80E-07 | -2.80E-07 | -2.80E-07 | -2.70E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -3.22E-07 | -3.21E-07 | -3.22E-07 | -3.23E-07 | -2.83E-07 | -2.83E-07 | -2.89E-07 | -2.76E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, High Pressure Injection System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -2.70E-08 | -2.70E-08 | -4.40E-08 | -4.40E-08 | -4.40E-08 | -4.40E-08 | -4.40E-08 | -4.40E-08 |
URI (ΔCDF) | 2.20E-07 | 2.20E-07 | -5.20E-08 | -5.20E-08 | -5.20E-08 | -5.20E-08 | -5.20E-08 | -5.20E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 1.93E-07 | 1.93E-07 | -9.60E-08 | -9.60E-08 | -9.60E-08 | -9.60E-08 | -9.60E-08 | -9.60E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -1.50E-08 | -1.50E-08 | -2.50E-08 | -3.60E-08 | -3.60E-08 | -3.60E-08 | -3.60E-08 | -3.60E-08 |
URI (ΔCDF) | 3.20E-07 | 3.20E-07 | 3.20E-07 | -4.70E-08 | -4.70E-08 | -4.70E-08 | -4.70E-08 | -4.70E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 3.05E-07 | 3.05E-07 | 2.95E-07 | -8.30E-08 | -8.30E-08 | -8.30E-08 | -8.30E-08 | -8.30E-08 |
Licensee Comments:
3Q/07: 7/17/08- Unit 1 RCIC Planned Unavailability changed from "39.17 hours" to "39.55 hours"for Sept. 2007 due to a discovery of a data collection error. No color change resulted from this correction.
Mitigating Systems Performance Index, Residual Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 8.00E-09 | 8.10E-09 | 1.70E-09 | 1.60E-09 | 2.40E-09 | 5.60E-09 | 6.20E-09 | 1.30E-08 |
URI (ΔCDF) | -3.60E-08 | -3.60E-08 | -3.20E-08 | -3.30E-08 | -3.40E-08 | -3.50E-08 | -3.50E-08 | -3.60E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -2.80E-08 | -2.79E-08 | -3.03E-08 | -3.14E-08 | -3.16E-08 | -2.94E-08 | -2.88E-08 | -2.30E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Cooling Water Systems | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 7.30E-09 | 7.40E-09 | 8.50E-09 | 7.90E-09 | 2.50E-08 | 2.60E-08 | 2.60E-08 | 2.70E-08 |
URI (ΔCDF) | -3.10E-09 | -3.10E-09 | -3.00E-09 | -2.90E-09 | -3.00E-09 | -3.00E-09 | -3.10E-09 | -3.10E-09 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 4.20E-09 | 4.30E-09 | 5.50E-09 | 5.00E-09 | 2.20E-08 | 2.30E-08 | 2.29E-08 | 2.39E-08 |
Licensee Comments: none
Reactor Coolant System Activity | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum activity | 0.000004 | 0.000004 | 0.000006 | 0.000005 | 0.000003 | 0.000059 | 0.000003 | 0.000003 | 0.000003 | 0.000003 | 0.000004 | 0.000004 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Reactor Coolant System Activity | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum activity | 0.000005 | 0.000003 | 0.000003 | 0.000004 | 0.000003 | 0.000003 | 0.000004 | 0.000004 | 0.000002 | 0.000002 | 0.000002 | 0.000002 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Reactor Coolant System Leakage | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum leakage | 2.300 | 2.200 | 2.300 | 2.500 | 2.250 | 2.600 | 2.400 | 2.600 | 3.000 | 3.200 | 3.200 | 2.400 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 9.2 | 8.8 | 9.2 | 10.0 | 9.0 | 10.4 | 9.6 | 10.4 | 12.0 | 12.8 | 12.8 | 9.6 |
Reactor Coolant System Leakage | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum leakage | 2.400 | 2.500 | 2.500 | 2.600 | 3.500 | 3.000 | 4.000 | 4.600 | 1.600 | 1.940 | 1.700 | 1.600 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 9.6 | 10.0 | 10.0 | 10.4 | 14.0 | 12.0 | 16.0 | 18.4 | 6.4 | 7.8 | 6.8 | 6.4 |
Licensee Comments: none
Drill/Exercise Performance | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful opportunities | 36.0 | 58.0 | 10.0 | 71.0 | 37.0 | 0 | 40.0 | 76.0 |
Total opportunities | 36.0 | 58.0 | 10.0 | 72.0 | 38.0 | 0 | 40.0 | 86.0 |
Indicator value | 97.8% | 98.9% | 98.9% | 98.7% | 98.4% | 98.9% | 99.0% | 96.5% |
Licensee Comments: none
ERO Drill Participation | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Participating Key personnel | 69.0 | 69.0 | 72.0 | 69.0 | 68.0 | 69.0 | 67.0 | 67.0 |
Total Key personnel | 69.0 | 69.0 | 72.0 | 69.0 | 68.0 | 69.0 | 67.0 | 67.0 |
Indicator value | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% |
Licensee Comments: none
Alert & Notification System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful siren-tests | 2140 | 2143 | 2140 | 2139 | 2143 | 2305 | 2142 | 2139 |
Total sirens-tests | 2145 | 2145 | 2145 | 2145 | 2145 | 2310 | 2145 | 2145 |
Indicator value | 99.7% | 99.8% | 99.8% | 99.8% | 99.8% | 99.8% | 99.8% | 99.8% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Action Matrix Summary | Inspection Findings Summary | PI Summary | Reactor Oversight Process
Last Modified: August 4, 2008