Search Options | ||||
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us |
Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned scrams | 1.0 | 0 | 0 | 0 | 0 | 1.0 | 1.0 | 0 |
Critical hours | 1897.2 | 2209.0 | 2159.0 | 2184.0 | 2164.0 | 1122.9 | 2135.3 | 2184.0 |
Indicator value | 1.9 | 1.9 | 1.9 | 0.8 | 0 | 0.9 | 1.8 | 1.8 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned power changes | 1.0 | 0 | 0 | 0 | 0 | 1.0 | 0 | 0 |
Critical hours | 1897.2 | 2209.0 | 2159.0 | 2184.0 | 2164.0 | 1122.9 | 2135.3 | 2184.0 |
Indicator value | 1.9 | 1.9 | 1.9 | 0.8 | 0 | 0.9 | 0.9 | 0.9 |
Licensee Comments: none
Unplanned Scrams with Complications | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (BWR) | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Safety System Functional Failures | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 2 |
Indicator value | 0 | 1 | 1 | 1 | 1 | 0 | 0 | 2 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 5.60E-08 | 1.30E-07 | 1.60E-07 | 1.70E-07 | 1.30E-07 | 9.30E-08 | 1.50E-07 | 1.80E-07 |
URI (ΔCDF) | -1.30E-06 | -1.30E-06 | 3.30E-07 | 1.50E-07 | -9.30E-08 | -1.40E-07 | -1.40E-07 | -1.40E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.24E-06 | -1.17E-06 | 4.90E-07 | 3.20E-07 | 3.70E-08 | -4.70E-08 | 1.00E-08 | 4.00E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, High Pressure Injection System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -2.30E-09 | 2.20E-08 | 2.20E-08 | -1.50E-08 | -1.50E-08 | -1.50E-08 | -1.50E-08 | -2.30E-08 |
URI (ΔCDF) | -5.00E-08 | -5.10E-08 | -5.10E-08 | -5.00E-08 | -4.80E-08 | -4.70E-08 | -4.70E-08 | -4.60E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -5.23E-08 | -2.90E-08 | -2.90E-08 | -6.50E-08 | -6.30E-08 | -6.20E-08 | -6.20E-08 | -6.90E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -6.60E-09 | -7.90E-09 | 1.70E-08 | 1.70E-08 | 9.30E-08 | 1.60E-07 | 1.20E-07 | 1.50E-07 |
URI (ΔCDF) | -7.60E-08 | -7.50E-08 | -7.60E-08 | -7.60E-08 | -8.20E-08 | -8.40E-08 | -8.10E-08 | -8.10E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -8.26E-08 | -8.29E-08 | -5.90E-08 | -5.90E-08 | 1.10E-08 | 7.60E-08 | 3.90E-08 | 6.90E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Residual Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 4.00E-08 | 3.50E-08 | 7.30E-08 | 7.10E-08 | 2.80E-08 | 3.00E-08 | 3.20E-08 | 2.80E-08 |
URI (ΔCDF) | -1.20E-07 | -1.20E-07 | -1.20E-07 | -1.20E-07 | -1.70E-07 | -1.70E-07 | -2.30E-07 | -2.30E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -8.00E-08 | -8.50E-08 | -4.70E-08 | -4.90E-08 | -1.42E-07 | -1.40E-07 | -1.98E-07 | -2.02E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, Cooling Water Systems | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 4.10E-08 | 7.40E-08 | 7.40E-08 | 9.90E-08 | 1.30E-08 | 1.60E-08 | 8.60E-08 | 8.30E-08 |
URI (ΔCDF) | -1.00E-07 | -1.00E-07 | -1.00E-07 | -1.00E-07 | -1.00E-07 | -1.00E-07 | -1.00E-07 | -1.00E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -5.90E-08 | -2.60E-08 | -2.60E-08 | -1.00E-09 | -8.70E-08 | -8.40E-08 | -1.40E-08 | -1.70E-08 |
Licensee Comments: none
Reactor Coolant System Activity | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum activity | 0.000034 | 0.000039 | 0.000031 | 0.000032 | 0.000051 | 0.000031 | 0.000032 | 0.000046 | 0.000050 | 0.000060 | 0.000049 | 0.000047 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Reactor Coolant System Activity | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum activity | 0.000051 | 0.000074 | 0.000068 | N/A | N/A | 0.000047 | 0.000056 | 0.000040 | 0.000046 | 0.000048 | 0.000049 | 0.000056 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0 | 0 | 0 | N/A | N/A | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Reactor Coolant System Leakage | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum leakage | 1.840 | 1.860 | 1.810 | 1.800 | 1.810 | 1.800 | 1.820 | 1.890 | 1.920 | 1.950 | 1.900 | 1.940 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 7.4 | 7.4 | 7.2 | 7.2 | 7.2 | 7.2 | 7.3 | 7.6 | 7.7 | 7.8 | 7.6 | 7.8 |
Reactor Coolant System Leakage | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum leakage | 1.910 | 1.900 | 1.910 | N/A | 1.810 | 1.620 | 1.600 | 1.600 | 1.610 | 1.610 | 1.610 | 1.610 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 7.6 | 7.6 | 7.6 | N/A | 7.2 | 6.5 | 6.4 | 6.4 | 6.4 | 6.4 | 6.4 | 6.4 |
Licensee Comments: none
Drill/Exercise Performance | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful opportunities | 60.0 | 25.0 | 18.0 | 25.0 | 8.0 | 2.0 | 6.0 | 74.0 |
Total opportunities | 62.0 | 25.0 | 19.0 | 25.0 | 9.0 | 3.0 | 6.0 | 78.0 |
Indicator value | 95.3% | 95.9% | 96.0% | 96.0% | 96.0% | 96.4% | 96.8% | 96.0% |
Licensee Comments: none
ERO Drill Participation | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Participating Key personnel | 103.0 | 103.0 | 106.0 | 105.0 | 97.0 | 95.0 | 94.0 | 90.0 |
Total Key personnel | 103.0 | 104.0 | 106.0 | 105.0 | 99.0 | 96.0 | 95.0 | 94.0 |
Indicator value | 100.0% | 99.0% | 100.0% | 100.0% | 98.0% | 99.0% | 98.9% | 95.7% |
Licensee Comments: none
Alert & Notification System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful siren-tests | 186 | 186 | 186 | 186 | 186 | 186 | 184 | 186 |
Total sirens-tests | 186 | 186 | 186 | 186 | 186 | 186 | 186 | 186 |
Indicator value | 99.7% | 99.7% | 99.7% | 100.0% | 100.0% | 100.0% | 99.7% | 99.7% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Action Matrix Summary | Inspection Findings Summary | PI Summary | Reactor Oversight Process
Last Modified: August 4, 2008