NUREG-0800
Cover, Contents, Introduction
Chapter 1
Chapter 2
Chapter 3
Chapter 4
Chapter 5
Chapter 6
Chapter 7
Chapter 8
Chapter 9
Chapter 10
Chapter 11
Chapter 12
Chapter 13
Chapter 14
Chapter 15
Chapter 16
Chapter 17
Chapter 18
Chapter 19
Appendixes

Reactor Coolant System and Connected Systems (NUREG-0800, Chapter 5)

The following links on this page are to documents in our Agencywide Documents Access and Management System (ADAMS). ADAMS documents are provided in either Adobe Portable Document Format (PDF) or Tagged Image File Format (TIFF). To obtain free viewers for displaying these formats, see our Plugins, Viewers, and Other Tools. If you have problems with viewing or printing documents from ADAMS, please contact the Public Document Room staff.

Section Title Rev. Date Updated
5.2.1.1 Compliance with the Codes and Standards Rule, 10 CFR 50.55a Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 01/1978
Rev. 0 11/1975
5.2.1.2 Applicable Code Cases Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 01/1978
Rev. 0 11/1975
5.2.2 Overpressure Protection Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 11/1988
Rev. 1 07/1981
Rev. 0 11/1975
5.2.3 Reactor Coolant Pressure Boundary Materials Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 04/1978
Rev. 0 11/1975
5.2.4 Reactor Coolant Pressure Boundary Inservice Inspection and Testing Rev. 2 03/2007
Draft Rev. 2 06/1996
Rev. 1 07/1981
Rev. 0 11/1975
5.2.5 Reactor Coolant Pressure Boundary Leakage Detection Rev. 2 03/2007
Draft Rev. 2 06/1996
Rev. 1 07/1981
Rev. 0 11/1975
5.3.1 Reactor Vessel Materials Rev. 2 03/2007
Draft Rev. 2 06/1996
Rev. 1 07/1981
Rev. 0 11/1975
5.3.2 Pressure-Temperature Limits, Upper-Shelf Energy, and Pressurized Thermal Shock Rev. 2 03/2007
Draft Rev. 2 06/1996
Rev. 1 07/1981
Rev. 0 11/1975
5.3.3 Reactor Vessel Integrity Rev. 2 03/2007
Draft Rev. 2 06/1996
Rev. 1 07/1981
Rev. 0 11/1975
5.4 Reactor Coolant System Component and Subsystem Design Rev. 2 03/2007
Draft Rev. 2 06/1996
Rev. 1 07/1981
Rev. 0 11/1975
5.4.1.1 Pump Flywheel Integrity (PWR) Rev. 2 03/2007
Draft Rev. 2 06/1996
Rev. 1 07/1981
Rev. 0 11/1975
5.4.2.1 Steam Generator Materials Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 11/1978
Rev. 0 11/1975
5.4.2.2 Steam Generator Program Rev. 2 03/2007
Draft Rev. 2 06/1996
Rev. 1 07/1981
Rev. 0 11/1975
5.4.6 Reactor Core Isolation Cooling System (BWR) Rev. 4 03/2007
Draft Rev. 4 06/1996
Rev. 3 04/1984
Rev. 2 07/1981
Rev. 1 03/1978
Rev. 0 11/1975
5.4.7 Residual Heat Removal (RHR) System Rev. 4 03/2007
Draft Rev. 4 06/1996
Rev. 3 04/1984
Rev. 2 07/1981
Rev. 1 08/1978
Rev. 0 11/1975
5.4.8 Reactor Water Cleanup System (BWR) Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 07/1978
Rev. 0 11/1975
5.4.11 Pressurizer Relief Tank Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 08/1978
Rev. 0 11/1975
5.4.12 Reactor Coolant System High Point Vents Rev. 1 03/2007
Draft Rev. 1 06/1996
Rev. 0 07/1981
5.4.13 Isolation Condenser System (BWR) Initial Issuance 03/2007
  Branch Technical Positions (BTPs)    
BTP 5-1 Monitoring of Secondary Side Water Chemistry in PWR Steam Generators (Former Section 5.4.2.1 BTP has been separated into an individual section.) Rev. 3 03/2007
BTP 5-2 Overpressurization Protection of Pressurized-Water Reactors While Operating at Low Temperatures (Former Section 5.2.2 BTP has been separated into an individual section.) Rev. 3 03/2007
BTP 5-3 Fracture Toughness Requirements Rev. 3 03/2007
BTP 5-4 Design Requirements of the Residual Heat Removal System Rev. 3 03/2007


Privacy Policy | Site Disclaimer