NAME: Nickel, Soluble Compounds (as Ni)
IMIS: 1842
CAS: 7440-02-0
NIOSH: RTECS QR5950000
DOT: 1378 32
DESCRIPTION:
Appearance and odor vary depending upon specific compounds.
INCOM: Strong acids, sulfur, Nickel nitrate; wood, other combustibles
Exposure Limits
OSHA GENERAL INDUSTRY PEL: 1 mg/m3
OSHA CONSTRUCTION INDUSTRY PEL: 1 mg/m3 TWA
ACGIH TLV: 0.1 mg/m3 TWA Soluble compounds: 1 mg/m3 TWA Metal 1 mg/m3 TWA Insoluble compounds
NIOSH REL: 0.015 mg/m3 TWA , potential carcinogen
Health Factors
NTP: Suspect Human Carcinogen
IARC: Nickel and Nickel Compounds - Group 1, carcinogenic to humans
SYMPTOM(s): Headache, vertigo; nausea, vomiting, epigastric pain; substernal pain; coughing, hyperpnea; cyanosis; weakness; leucocytosis, pneumonitis; delirium, convulsions; (carcinogenic)
HEALTH EFFECTS: Cumulative lung damage (HE10); Dermatitis (HE3)
ORGAN: Lungs, paranasal sinus, CNS
Monitoring
PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):
MEDIA: Mixed Cellulose Ester Filter (MCEF) 0.8 microns
ANL SOLVENT: Deionized water
MAX V: 960 Liters MIN V: 480 Liters MAX F: 2.0 L/min
ANL 1: Atomic Absorption Spectroscopy; AAS
REF: 2 (OSHA ID-121)
SAE: 0.13
CLASS: Fully Validated
ANL A: Inductively Coupled Argon Plasma; ICP/DCP-AES
REF: 2 (OSHA ID-125G)
SAE: 0.10
CLASS: Fully Validated
NOTE: If the filter is not overloaded, samples may be collected up to an 8-hour period.
SECONDARY SAMPLING/ANALYTICAL METHOD (SAM2):
DEVICE: Detector Tube COMPANY: Draeger
PART #: 67 28871 RANGE: 0.25-1 mg/m3
CLASS: Mfg
|