skip navigation links 
 
 Search Options 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page

Event Notification Report for September 7, 2005

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
09/05/2005 - 09/07/2005

** EVENT NUMBERS **


41954 41970

To top of page
Power Reactor Event Number: 41954
Facility: WATERFORD
Region: 4 State: LA
Unit: [3] [ ] [ ]
RX Type: [3] CE
NRC Notified By: KENNY CAMBREY
HQ OPS Officer: JEFF ROTTON
Notification Date: 08/27/2005
Notification Time: 23:22 [ET]
Event Date: 08/27/2005
Event Time: 22:04 [CDT]
Last Update Date: 09/07/2005
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
WILLIAM JONES (R4)
PAO-TSIN KUO (NRR)
MEL LEACH (IRD)
AKERS (DHS)
CASTO (FEMA)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation

Event Text

UNUSUAL EVENT DECLARED DUE TO HURRICANE WARNING

At 2204 CDT, an Unusual Event was declared due to a Hurricane warning in St Charles Parish, LA. The licensee does not have any Limiting Conditions for Operation on safety related equipment. No electrical grid disturbances currently exist.

The licensee will be notifying the NRC Resident Inspector. The licensee notified the State and Local government agencies.

* * * UPDATE FROM J. PIERCE TO M. RIPLEY 1144 EDT 08/28/05 * * *

"Waterford 3 will commence a plant shutdown to Mode 4 on August 28, 2005 at 1100 CDT. The goal is to be approximately 325 deg F reactor coolant system temperature with both trains of Shutdown Cooling in service [expected at approximately 0100 CDT 08/29/05] . This is approximately 2 hours before hurricane force winds are expected on site."

Notified R4DO (Jones), NRR EO (Kuo), IRD Mgr. (Wilson), DHS (York), and FEMA (Canupp).

* * * UPDATE FROM J. PIERCE TO J. ROTTON 1131 EDT 08/29/05 * * *

As a result of Hurricane Katrina, all offsite power was lost at 0800 CDT. The emergency diesel generators successfully started and loaded.

Notified R4DO (R. Bywater), NSIR (Leach, Wilson), NRR EO (Kuo, Jung), FEMA (Kuzia), DHS (Stransky).

* * * UPDATE FROM LICENSEE (LEWIS) TO NRC (HUFFMAN) AT 2302 EDT ON 8/29/05 * * *

The Hurricane warning for St Charles Parish, LA, has been discontinued by the National Weather Service. Initiating condition, D UE-5, is no longer applicable. Waterford 3 remains in an Unusual Event for initiating condition C UE-1, loss of all offsite power. An agreement to relax 60 minute notification updates to State and local authorities remains in effect.

The licensee has notified State and local authorities as well as the NRC Resident Inspector.

Offsite power is available to the licensee switchyard. However, the voltage is too high for plant specification and the licensee remains disconnected from offsite power and on the emergency diesel generators.

* * * UPDATE FROM LICENSEE (LEWIS) TO NRC (KNOKE) AT 0001 EDT ON 8/31/05 * * *

Waterford 3 remains in an Unusual Event for initiating condition C UE-1, loss of all offsite power. An agreement to relax 60 minute notification updates to State and local authorities remains in effect. The communications system for Public Automatic Branch Exchange (PABX) is working internally, but not externally. Other areas where communications are lost are Emergency Operations Facility (EOF), Operations hotline, Reactor Auxiliary Building (RAB), and the Emergency Notification System (ENS). Waterford has use of an industrial hotline to a circuit in the Parish of St Charles, however, this is very limited in its capability. The Civil Defense communication system is still inoperable.

* * * UPDATE AT 1903 ON 9/6/05 FROM WAIG TO GOULD * * *

NRC exited monitoring mode at 1800 CDT on 9/6/05.

Notified R4 IRC (Waig), R4DO (Powers), IRD (Leach), DHS (Cartlidge), FEMA (Kuzia).

To top of page
Power Reactor Event Number: 41970
Facility: ARKANSAS NUCLEAR
Region: 4 State: AR
Unit: [1] [2] [ ]
RX Type: [1] B&W-L-LP,[2] CE
NRC Notified By: JAMES CRABILL
HQ OPS Officer: ARLON COSTA
Notification Date: 09/06/2005
Notification Time: 21:45 [ET]
Event Date: 09/06/2005
Event Time: 14:05 [CDT]
Last Update Date: 09/06/2005
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
DALE POWERS (R4)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation

Event Text

QUALITY ASSURANCE FITNESS FOR DUTY BLIND SAMPLES TESTING

"This event was determined to be reportable per 10 CFR26 Appendix A Section 2.8(e)(4): The licensee shall investigate any unsatisfactory (blind) performance testing result. A record shall be made of the investigation findings and the corrective actions taken by the laboratory.

"Event Description: Two known positive Fitness for Duty QA blind samples (both had the same lot number) were sent to the drug testing laboratory and both results came back negative."

The licensee will notify the NRC Resident Inspector.



Privacy Policy | Site Disclaimer
Tuesday, February 20, 2007