Technical Report Documentation Page |
1. Report No. DOT HS 809 424 |
2. Government Accession No. |
3. Recipient's Catalog No. |
|
4. Title and Subtitle
Special Testing for Possible Carry Over Effects Using the Intoximeters, Inc. Alco-Sencor IV at 10 degrees Celcius |
5. Report Date March 2002 |
||
6. Performing Organization Code |
|||
7. Author(s)
CONDE, Edward |
8. Performing Organization Report No.
|
||
9. Performing Organization Name and Address
Volpe National Transportation Systems Center |
10. Work Unit No. (TRAIS) |
||
11. Contract or Grant No. PPA #234 |
|||
12. Sponsoring Agency Name and Address
National Highway Traffic Safety Administration |
13. Type of Report and Period Covered Technical Note |
||
14. Sponsoring Agency Code |
|||
15. Supplementary Notes
Dr. James F. Frank was the project monitor for this project. |
|||
16. Abstract
Laboratory testing showed that when simulator samples at 0.170 grams of ethanol per 210 liters were repeatedly tested with an Intoximeters, Inc. Alco-Sensor IV at 10 degrees C. ambient temperature, some ethanol and water eventually condensed onto the cool airway surfaces of the instrument. When the instrument was operated in screener mode without any heating element and without proper protocols, some of this alcoholic condensate carried over to subsequent screening tests. However, no carry over was seen when the Alco-Sensor IV was operated in the evidential mode, or when the optional CEM heating accessory was used, or when proper test protocols were used. The results show that the possibility for the occurrence of carry over in breath testing must be addressed when operating at low ambient temperatures, particularly when using unheated breath testers. The results also show that the potential for carry over can be eliminated easily by using procedural controls, such as performing an air blank before the test, or by testing two separate breath samples and/or by using a warm air flushing of the breath tester airway. A table listing all breath testers on both the NHTSA Conforming Products List (CPL) for Screening Devices, as well as the Evidential Breath Tester CPL indicates whether specific devices have a built-in heater, or a flushing pump, and whether the instructions accompanying them address the possibility of alcohol carry over during low temperature operations. | |||
17. Key Words
Alcohol, breath alcohol testing, Alco-Sensor IV, carry over effects, Driving under the Influence (DUI) |
18. Distribution Statement
Copy available from National Technical Information Service, Springfield, Virginia 22160. Also see www.nhtsa.dot.gov for a copy. |
||
19. Security Classif. (of this report)
Unclassified |
20. Security Classif. (of this page)
Unclassifed |
21. No. of Pages
5 |
22. Price |
Form DOT F 1700.7 (8-72) | Reproduction of completed page authorized |