Technology Services, National Voluntary Laboratory Accreditation Program, NIST Go to Technology Services Home Page Go to NIST Home Page Go to National Voluntary Laboratory Accreditation Program Home Page Go to Directory of Accredited Laboratories Go to Fields of Accreditation Go to Publications/Applications Go to Mutual Recognition Arrangements Go to Assessor Resources Contact National Voluntary Laboratory Accreditation Program

U.S. Army Dosimetry Center

NVLAP Lab Code: 100539-0


Address and Contact Information:

Attn: AMSAM-TMD-SD, Bldg. 5417
Redstone Arsenal, AL 35898-5000
Contact: Mr. William S. Harris, Jr.
Phone: 256-876-1786
Fax: 256-876-3816
E-Mail: william.harris3@us.army.mil
Send E-Mail to Laboratory: U.S. Army Dosimetry Center

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of January 8, 2009. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Ionizing Radiation Dosimetry

Accreditation Valid From: January 1, 2009 Through: December 31, 2009

By actual demonstration of compliance with ANSI N13.11-2001,
this facility has been evaluated and deemed competent to
process the radiation dosimeter listed below through
employing Panasonic automatic readers Model UD-710 and
UD-7900.

Whole-body - Panasonic Model UD-802AS in a Panasonic
UD-874AT holder for Categories IA, IB, IC, IIA, IIB, IIC,
IID, IIIA, IIIB, IIIC, IVA, IVB, IVC, VAB, VICB.

Whole-body - Inlight Basic (OSL/PAN insert) with Panasonic
UD 874AT holder for Categories IA, IIA, IVA, VAB.

By actual demonstration of compliance with ANSI N13.11-2001,
the Deployable Dosimetry Laboratory of this facility has
been evaluated and deemed competent to process the radiation
dosimeter listed below through employing a Panasonic
automatic reader Model UD-7900.

Whole-body - Panasonic Model UD-802AS in a Panasonic
UD-874AT holder for Categories IA, IB, IC, IIA, IIB, IIC,
IID, IIIA, IIIB, IIIC, IVA, IVB, IVC, VAB, VICB.

By actual demonstration of compliance with ANSI N13.32-1995,
this facility has been evaluated and deemed competent to
process the extremity radiation dosimeter listed below
through employing a Harshaw Model 6600 reader.

Extremity - finger ring - Harshaw model DXT-RAD (TLD-100) in
a Harshaw DXT RAD holder for Categories I, II, IIIA, IVA,
VA, VB, VD.

Return to NVLAP Program Listing


Return to top of page NVLAP Home | Accredited Laboratories | Fields of Accreditation | Publications/Applications |
Mutual Recognition Arrangements | Assessor Resources | Contact NVLAP
Return to top of page

For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:

National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov

Date created: July 26, 2002
Last Updated: January 8, 2009

Privacy Statement / Security Notice / Accessibility Statement | Disclaimer | FOIA