Skip Standard Navigation Links
Centers for Disease Control and Prevention
 CDC Home Search Health Topics A-Z
peer-reviewed.gif (582 bytes)
eid_header.gif (2942 bytes)
Past Issue

Vol. 8, No. 10
October 2002
 EID Home | Ahead of Print | Past Issues | EID Search | Contact Us | Announcements | Suggested Citation


Acknowledgments
References
Figure
Table
Comments


Download Article
PDF
Help
Feedback

This page was updated on February 28, 2003 to incorporate the corrections in Vol. 9, No. 4

Letter

Evaluation and Validation of a Real-Time Polymerase Chain Reaction Assay for Rapid Identification of Bacillus anthracis

Suggested citation for this article: Hoffmaster AF, Meyer RF, Bowen M, Marston CK, Weyant RS, Thurman K, et al. Evaluation and validation of a real-time polymerase chain reaction assay for rapid identification of Bacillus anthracis. Emerg Infect Dis [serial online] 2002 Oct [date cited];8. Available from: URL: http://www.cdc.gov/ncidod/EID/vol8no10/02-0393.htm


To the Editor: During the 2001 anthrax outbreak, we evaluated and validated a highly sensitive and specific three-target (two plasmid and one chromosomally located target) 5´ nuclease assay (real-time polymerase chain reaction [PCR]) for detection and identification of Bacillus anthracis. This PCR assay was successfully used to rapidly test hundreds of suspect isolates as well as screen environmental samples for the presence of B. anthracis throughout the 2001 anthrax outbreak. For the first time in an outbreak setting, a PCR assay was used to detect B. anthracis directly from clinical specimens, consequently becoming a part of the laboratory confirmation of anthrax. In this letter, we describe the evaluation of this assay on a diverse panel of bacterial isolates including isolates obtained throughout the outbreak. A supplement, which includes data on the use of this assay on environmental and clinical specimens, is online (available from: URL: http://www.cdc.gov/ncidod/EID/vol8no10/02-0393sup.htm).

Identification of B. anthracis has traditionally been determined by using phenotypic differences between B. anthracis and the rest of the B. cereus group (i.e., lack of motility and hemolysis, susceptibility to penicillin, typical colony morphology, and susceptibility to lysis by gamma phage); however, these methods are slow and require at least 24 h for completion. The recent bioterrorism-associated outbreak and the ongoing threat emphasize the importance of rapid microbiologic diagnosis for the timely and adequate implementation of control and preventative measures.

For B. anthracis, the main targets for development of such assays, primarily PCR-based, have been and continue to be genes encoding its virulence factors: a tripartite exotoxin and an antiphagocytic capsule (1–4). The toxin genes (pagA, lef, and cya) are encoded on the 182-kb virulence plasmid, pXO1, while the genes required for capsule biosynthesis (capB, capC, and capA) are encoded on the 96-kb virulence plasmid, pXO2 (5–7). These plasmid-located virulence genes seem to be restricted to B. anthracis, giving the plasmid-based assays a high degree of specificity (8). However, strains of B. anthracis that lack these plasmids have been reported (4,9). Consequently, having an assay focus on a specific chromosomal target for detection of avirulent and plasmid-cured B. anthracis, as well as those that potentially could have been genetically engineered, is essential. Chromosomal markers, such as vrrA and Ba813, have been used to characterize B. anthracis (912) and to detect it in tissues of victims of the anthrax outbreak that occurred in 1979 in Sverdlovsk, former Soviet Union (12), but these markers are not restricted to B. anthracis. Recently, Qi et al. developed a fluorescence resonance energy transfer PCR assay that targets the B. anthracis chromosomally located rpoB gene. This assay appears to be the most specific described to date with only 1 of 175 non-B. anthracis bacilli reported as positive (13).

Over the past several years, activities in the area of bioterrorism preparedness in the United States have resulted in the establishment of an international Laboratory Response Network (LRN), which was instrumental in the identification of the agent used in the 2001 outbreak (14). One of the major initiatives of LRN has been development and validation of rapid and specific assays for identification of B. anthracis and other agents likely to be used in a bioterrorism event.

Primer and probe set BA1 targets a region of pX02, BA2 targets pX01, and BA3 targets a region of the B. anthracis chromosome. Probes were labeled with 6-carboxy-fluorescein phosphoramidite and 5-carboxy-tetramethyl-rhodamine.

LRN PCR assays using the BA1, BA2, and BA3 primer and probe sets were performed with the LightCycler (Roche Diagnostics GmbH, Mannheim, Germany), Smart Cycler (Cepheid, Sunnyvale, CA), or ABI Prism 7700 (Applied Biosystems, Foster City, CA) instruments. The LightCycler Faststart DNA master hybridization probes kit (Roche Diagnostics GmbH) reagents were used on all real-time platforms. Reactions comprised 1X reaction mix, 5 mM MgCl2, 500 nM each primer, and 100 nM probe in a reaction volume of 20 µL (LightCycler) or 25 µL (Smart Cycler, ABI Prism 7700). Thermal cycler conditions consisted of an initial 10-min hold at 95°C followed by 40–45 cycles of 10 s (LightCycler) or 15 s (Smart Cycler, ABI Prism 7700) at 95°C and 30 s (LightCycler, Smart Cycler) or 60 s (ABI Prism 7700) at 60°C. Real-time data were collected during the 60°C extension step of each cycle. Amplification of the human βbeta-actin gene was used as a real-time PCR control when used on clinical samples to ensure negative results were not from inhibition of the PCR reaction. This real-time PCR assay was considered positive when all three targets were positive (Figure).

Figure
Figure

Click to view enlarged image

Figure. Real-time polymerase chain reaction graph of three B. anthracis markers and b-actin control detected in a pleural fluid specimen from a patient with inhalational anthrax....

A total of 542 isolates were tested. Eighty-one B. anthracis isolates were tested to evaluate sensitivity of the real-time PCR approach (Table). Seventy-five were selected to provide a test population representing diverse sources, genotypes, geographic origins, and dates of isolation. The isolates included those collected from animals, humans, and other sources (i.e., industrial sites associated with anthrax outbreaks); the isolates span at least 58 years (1939–1997). Fifty-three of the isolates were previously characterized by multiple-locus variable-number tandem repeat analysis (MLVA) (15) and were included to ensure a representative range of the 89 described MLVA genotypes to date. Six B. anthracis type and standard strains included: five pXO1 cured strains (including the Pasteur strain) and one pXO2 cured strain (the veterinary vaccine strain Sterne). The B. anthracis New Hampshire strain (16) was used as a positive control for all real-time PCR assays. This isolate was originally cultured from a patient with inhalational anthrax in New Hampshire in 1957. This real-time PCR is designed to identify fully virulent (wild-type) B. anthracis, which will give positive results in all three markers. However, naturally occurring isolates have been found lacking either virulence plasmid, and a number of laboratory strains have been plasmid cured, as well. PCR results for these strains will reflect the lack of one or both of their plasmids.

A total of 317 B. anthracis isolates obtained during the bioterrorism-associated anthrax outbreak from October to December 2001 were also analyzed by PCR. These included 27 isolates from clinical specimens, 4 from powders and 286 isolates from environmental samples. MLVA was performed on 135 of these isolates; all were indistinguishable (17).

For evaluation of the assays’ specificity we tested 56 archived members of the Bacillus genus: B. subtilis (9 strains, 5 clinical, 4 unknown), B. cereus (23 strains, 9 clinical, 14 environmental), B. thuringiensis (12 strains, 6 clinical, 3 insects, 3 unknown), B. mycoides (1 strain, unknown), B. megaterium (10 strains, 7 clinical, 3 unknown), and the environmental Bacillus spp. isolate, Ba813_11, which resulted in a previously reported false-positive result in the B. anthracis-specific PCR assay targeting rpoB (13). In addition, 88 isolates from environmental and clinical specimens, which were confirmed not to be B. anthracis by standard microbiologic methods were tested. These isolates were selected because of their lack of hemolysis and because they had a colony morphology similar to B. anthracis on blood agar plates.

Before testing, all strains were stored at –70°C in brain heart infusion broth (BHIB, Centers for Disease Control and Prevention [CDC], Atlanta, GA) or water containing 20% glycerol. Identification of all strains was confirmed by using standard microbiologic procedures and the LRN testing algorithm (14,18). Colony-lysis DNA preparations were used for all Bacillus spp. strains. Isolates were streaked onto trypticase soy agar containing 5% sheep blood (Becton Dickinson Microbiology Systems, Cockeysville, MD) and incubated overnight at 37°C. A single colony was transferred and dispersed into 0.22 mM centrifugal filter units (Millipore, Bedford, MA) containing 200 mL 10 mM Tris-HCl (pH 8.0). The suspension was heated at 95°C for 20 min and then cooled to room temperature. The filter units were then centrifuged at 6,000 x g in a microfuge for 2 min and the filter discarded. The resulting lysate was stored at –20°C until use.

The lower limit of detection of each assay was tested by using five B. anthracis strains: Ames (2000031656), Pakistan-sheep (2000031648), French-bovine (2000031651), Sterne (2000031075), and Pasteur (2000031759). DNA was extracted from vegetative cells by first pre-treating cell pellets with lysozyme and lysostaphin and then using the MasterPure DNA Purification kit (Epicentre, Madison, WI), following the manufacturer’s protocol for cell samples. B. anthracis spores were quantitated microscopically and tested directly in the real-time PCR assay without DNA extraction. Vegetative-cell DNA was tested at concentrations ranging from 10 ng to 400 fg DNA per reaction. Spores were tested at concentrations ranging from 100,000 spores to 1 spore per reaction. All reactions were performed in duplicate on the LightCycler, Smart Cycler, and ABI Prism 7700 instruments.

All 75 wild-type (fully virulent) B. anthracis isolates tested were positive for all three targets resulting in 100% sensitivity (95% confidence interval [CI] 95% to 100%). Strains cured of pXO1 or pXO2 produced negative results for the loci specific to these plasmids (Table). In addition, all 317 B. anthracis isolates from the 2001 outbreak were also positive for all three PCR targets (Table).

None of the 56 archived non–B. anthracis isolates, representing five other Bacillus species was positive for any of the three LRN PCR targets, including the Bacillus spp. isolate, Ba813_11, resulting in 100% specificity (95% CI 94% to 100%). Results were also negative for 88 clinical and environmental isolates, which were determined by standard microbiologic methods not to be B. anthracis (specificity 100%, 95% CI 96% to 100%).

The limit of detection on the LightCycler, Smart Cycler, and ABI Prism 7700 instruments, as determined by using DNA extracted from vegetative cells of the Sterne and Pasteur reference strains, was 1 pg DNA (approximately 167 cells based on a 5.5 Mbp genome size). Five to 10 spores could be detected on the ABI Prism 7700 instrument for the Ames (2000031656), Pakistan-sheep (2000031648), French-bovine (2000031651), and Sterne (2000031075) strains of B. anthracis.

The recent bioterrorism-associated anthrax outbreak demonstrated the need for sensitive, specific, and rapid methods for diagnosis and confirmation of anthrax, both for identification of suspect B. anthracis isolates and direct detection of B. anthracis DNA in clinical specimens. When tested on >500 strains, representing B. anthracis and five other Bacillus species, the LRN PCR exhibited 100% sensitivity and specificity.

To date, designing PCR assays for identification of B. anthracis has primarily focused on genes located on the plasmids (1–4). Patra et al. used a PCR that targeted two chromosomal loci, vrrA and Ba813, and found numerous environmental Bacillus isolates other than B. anthracis that were positive for both Ba813 and vrrA (11). While assays focusing on plasmid targets allow for a high level of specificity, a specific chromosomal target for detection of avirulent and plasmid-cured B. anthracis strains is needed. Thus, the LRN PCR includes a chromosomal target in addition to targets on each of the two virulence plasmids, pXO1 and pXO2.

Closely related B. cereus and B. thuringiensis, notorious for generating false-positive results using assays designed to be specific for B. anthracis (11,13), were consistently negative in this real-time PCR assay. B. anthracis, B. cereus, and B. thuringiensis are so closely related that their distinction as separate species is frequently questioned based on DNA-DNA hybridization studies, multiple-locus enzyme electrophoresis, and 16S rRNA sequence similarity (1921). We have selected non–B. anthracis isolates that were primarily of clinical as opposed to environmental origin. B. cereus and B. thuringiensis clinical isolates are even more closely related to B. anthracis than their environmental counterparts (19,22), and they are more likely to cause false-positive results. We also tested the Bacillus spp. isolate that caused the one false-positive result in the Qi et al. report (13). Despite all of these challenges, all three targets of this real-time PCR assay have demonstrated 100% specificity and sensitivity in identification of B. anthracis when tested against our panel of Bacillus spp. strains and in identification of 317 outbreak-associated B. anthracis isolates. This LRN PCR is currently the only real-time PCR assay that detects both plasmid and chromosomal targets with 100% specificity and sensitivity. In addition, real-time PCR assays using fluorescent probes provide great sensitivity; this assay was able to detect 1 pg of purified DNA from vegetative cells (equivalent to 167 cells) or directly detect 5–10 spores.

The high level of sensitivity and specificity of the LRN PCR assay can be attributed to several factors. An extensive panel of DNA samples (non-Bacillus gram-positive bacterial species, gram-negative bacterial species, and human, vertebrate, and invertebrate DNA) were tested (data not shown). Having more than a single target decreases the rate of both false-negative and false-positive results, as they are not dependent on a single locus. The use of multiple targets also decreases the risk of false-positive results from contamination because each target is amplified as a separate PCR reaction. Finally, 5´ nuclease assays makes use of a fluorescent oligonucleotide probe, in addition to the forward and reverse primers, that allows for a lower limit of detection compared to conventional PCR, eliminates the need for post-PCR processing, and increases specificity (23,24).

The LRN PCR was shown to be important for use on environmental and clinical specimens during the 2001 bioterrorism-associated anthrax outbreak. A supplement covering the use of this assay on these specimens can be seen online (available from: URL: http://www.cdc.gov/ncidod/EID/vol8no10/02-0393sup.htm). The LRN PCR assay is widely available at over 200 laboratories in several countries and all 50 states of the United States through the Laboratory Response Network. The system is designed to be accessed through the State Department of Health.

Acknowledgments

We thank Al Mateczun for primer and probe sequences; Nancy McKinney for technical support; Guy Patra, Vito G. DelVecchio, Paul Keim, Martin Hugh-Jones, Peter Turnbull, and Paul J. Jackson for providing Bacillus anthracis and Bacillus species strains; the Rapid Response and Advanced Technology Laboratory and Epidemiologic Investigations Laboratory staff for technical support; and the Laboratory Response Network for meeting the infrastructure challenge.

Alex R. Hoffmaster, Richard F. Meyer, Michael P. Bowen, Chung K. Marston, Robbin S. Weyant, Kathy Thurman, Sharon L. Messenger, Erin E. Minor, Jonas M. Winchell, Max V. Rasmussen, Bruce R. Newton, J. Todd Parker, William E. Morrill, Nancy McKinney, Gwen A. Barnett, James J. Sejvar, John A. Jernigan, Bradley A. Perkins, and Tanja Popovic
Centers for Disease Control and Prevention, Atlanta, Georgia, USA

References

  1. Makino SI, Cheun HI, Watarai M, Uchida I, Takeshi K. Detection of anthrax spores from the air by real-time PCR. Lett Appl Microbiol 2001;33:237–40.
  2. Makino SI, Iinuma-Okada Y, Maruyama T, Ezaki T, Sasakawa C, Yoshikawa M. Direct detection of Bacillus anthracis DNA in animals by polymerase chain reaction. J Clin Microbiol 1993;31:547–51.
  3. Lee MA, Brightwell G, Leslie D, Bird H, Hamilton A. Fluorescent detection techniques for real-time multiplex strand specific detection of Bacillus anthracis using rapid PCR. J Appl Microbiol 1999;87:218–23.
  4. Turnbull PC, Hutson RA, Ward MJ, Jones MN, Quinn CP, Finnie NJ, et al. Bacillus anthracis but not always anthrax. J Appl Bacteriol 1992;72:21–8.
  5. Okinaka RT, Cloud K, Hampton O, Hoffmaster AR, Hill KK, Keim P, et al. Sequence and organization of pXO1, the large Bacillus anthracis plasmid harboring the anthrax toxin genes. J Bacteriol 1999;181:6509–15.
  6. Okinaka RT, Cloud K, Hampton O, Hoffmaster AR, Hill KK, Keim P, et al. Sequence, assembly and analysis of pXO1 and pXO2. J Appl Microbiol 1999;87:261–2.
  7. Green BD, Battisti L, Koehler TM, Thorne CB, Ivins BE. Demonstration of a capsule plasmid in Bacillus anthracis. Infect Immun 1985;49:291–7.
  8. Pannucci J, Okinaka RT, Sabin R, Kuske CR. Bacillus anthracis pXO1 plasmid sequence conservation among closely related bacterial species. J Bacteriol 2002;184:134–41.
  9. Ramisse V, Patra G, Garrigue H, Guesdon GL, Mock M. Identification and characterization of Bacillus anthracis by multiplex PCR analysis of sequences on plasmids pXO1 and pXO2 and chromosomal DNA. FEMS Microbiol Lett 1996;145:9–16.
  10. Ramisse V, Patra G, Vaissaire J, Mock M. The Ba813 chromosomal DNA sequence effectively traces the whole Bacillus anthracis community. J Appl Microbiol 1999;87:224–8.
  11. Patra G, Vaissaire J, Weber-Levy M, Le Doujet C, Mock M. Molecular characterization of Bacillus strains involved in outbreaks of anthrax in France in 1997. J Clin Microbiol 1998;36:3412–4.
  12. Jackson PJ, Hugh-Jones ME, Adair DM, Green G, Hill KK, Kuske CR, et al. PCR analysis of tissue samples from the 1979 Sverdlovsk anthrax victims: the presence of multiple Bacillus anthracis strains in different victims. Proc Natl Acad Sci U S A 1998;95:1224–9.
  13. Qi Y, Patra G, Liang X, Williams LE, Rose S, Redkar RJ, et al. Utilization of the rpoB gene as a specific chromosomal marker for real-time PCR detection of Bacillus anthracis. Appl Environ Microbiol 2001;67:3720–7.
  14. Khan AS, Morse S, Lillibridge SR. Public-health preparedness for biological terrorism in the USA. Lancet 2000;356:1179–82.
  15. Keim P, Price LB, Klevytska AM, Smith KL, Schupp JM, Okinaka R, et al. Multiple-locus variable-number tandem repeat analysis reveals genetic relationships within Bacillus anthracis. J Bacteriol 2000;182:2928–36.
  16. Plotkin SA, Brachman PS, Utell M, Bumford FH, Atchison MM. An epidemic of inhalation anthrax, the first in the twentieth century. Am J Med 1960;29:992–1001.
  17. Hoffmaster AR, Fitzgerald CC, Ribot E, Mayer LW, Popovic T. Importance of molecular subtyping of B. anthracis during the recent multi-state bioterrorism-associated anthrax outbreak in the United States. Emerg Infect Dis 2002. (this issue)
  18. Logan NA, Turnbull PC. Bacillus and recently derived genera. In: Murray PR, editor. Manual of clinical microbiology. Washington (DC): ASM Press; 2001. p. 357–69.
  19. Helgason E, Okstad OA, Caugant DA, Johansen HA, Fouet A, Mock M, et al. Bacillus anthracis, Bacillus cereus, and Bacillus thuringiensis—one species on the basis of genetic evidence. Appl Environ Microbiol 2000;66:2627–30.
  20. Ash C, Farrow JA, Dorsch M, Stackebrandt E, Collins MD. Comparative analysis of Bacillus anthracis, Bacillus cereus, and related species on the basis of reverse transcriptase sequencing of 16S rRNA. Int J Syst Bacteriol 1991;41:343–6.
  21. Kaneko T, Nozaki R, Aizawa K. Deoxyribonucleic acid relatedness between Bacillus anthracis, Bacillus cereus and Bacillus thuringiensis. Microbiol Immunol 1978;22:639–41.
  22. Ticknor LO, Kolsto AB, Hill KK, Keim P, Laker MT, Tonks M, et al. Fluorescent amplified fragment length polymorphism analysis of Norwegian Bacillus cereus and Bacillus thuringiensis soil isolates. Appl Environ Microbiol 2001;67:4863–73.
  23. Cockerill FR, Smith TF. Rapid-cycle real-time PCR: a revolution for clinical microbiology. ASM News 2002;68:77–83.
  24. Livak KJ, Flood SJ, Marmaro J, Giusti W, Deetz K. Oligonucleotides with fluorescent dyes at opposite ends provide a quenched probe system useful for detecting PCR product and nucleic acid hybridization. PCR Methods Appl 1995;4:357–362.

Table.  Origin, designations, and results of real-time polymerase chain reaction assay for Bacillus anthracis strainsa

B. anthracis

No. analyzed

Temporal range and geographic origin

MLVA genotypes representeda

No. positive/total


Ba1b

Ba2b

Ba3b


Human isolates

30

1943–1996
Africa, Asia, Australia, Europe, North America

3, 4, 22, 23, 28, 32, 34, 35, 36, 37, 41, 43, 44, 45, 50, 66, 68

30/30

30/30

30/30

Animal isolates

29

1939–1997
Africa, Asia, Australia, Europe, North America, South America

3, 10, 20, 26, 29, 30, 35, 38, 40, 45, 48, 49, 51, 55, 57, 78, 80, 81, 84, 85, 87, 89

29/29

29/29

29/29

Other isolates

16

1950–1993
Africa, Asia, Europe, N. America

13, 14, 21, 24, 47, 62, 69, 73, 77, 79, 82

16/16

16/16

16/16

Outbreak isolates

317

2001
U.S. outbreak

62

317/317

317/317

317/317

pXO1 cured

5

1956–1974
 North America

 

5/5

0/5

5/5

pXO2 cured

1

Africa

 

0/1

1/1

1/1


aMLVA, multiple-locus variable-number tandem repeat analysis as described by Keim et al. (15).
bBa1, Ba2, and Ba3 primer/probe sets as described in Materials and Methods.

 

   
     
   
Comments to the Authors
Address for correspondence: Alex R. Hoffmaster, Epidemiologic Investigations Laboratory, Meningitis and Special Pathogens Branch, Division of Bacterial and Mycotic Diseases, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Mailstop G34, 1600 Clifton Road, N.E., Atlanta, GA 30333, USA; fax: (404) 639-3023; e-mail: amh9@cdc.gov

Comments to the EID Editors
Please use this form to submit comments to the EID Editors.

Email (optional)


 

EID Home | Top of Page | Ahead-of-Print | Past Issues | Suggested Citation | EID Search | Contact Us | Accessibility | Privacy Policy Notice | CDC Home | CDC Search | Health Topics A-Z

This page posted September 13, 2002
This page last reviewed May 10, 2005

Emerging Infectious Diseases Journal
National Center for Infectious Diseases
Centers for Disease Control and Prevention