Perimeter Columns: Non-Mandatory Guidelines for Complying with 1926.756(e) To Protect the Unprotected Side or Edge of a Walking/Working Surface. - 1926 Subpart R App F

Regulations (Standards - 29 CFR) - Table of Contents Regulations (Standards - 29 CFR) - Table of Contents
• Part Number: 1926
• Part Title: Safety and Health Regulations for Construction
• Subpart: R
• Subpart Title: Steel Erection
• Standard Number: 1926 Subpart R App F
• Title: Perimeter Columns: Non-Mandatory Guidelines for Complying with 1926.756(e) To Protect the Unprotected Side or Edge of a Walking/Working Surface.

Appendix F to Subpart R -- Perimeter Columns: Non-Mandatory Guidelines for Complying with § 1926.756(e) To Protect the Unprotected Side or Edge of a Walking/Working Surface



In multi-story structures, when holes in the column web are used for perimeter safety cables, the column splice must be placed sufficiently high so as not to interfere with any attachments to the column necessary for the column splice. Column splices are recommended to be placed at every other or fourth levels as design allows. Column splices at third levels are detrimental to the erection process and should be avoided if possible.

[66 FR 5277, Jan. 18, 2001]


Next Standard (1926 Subpart R App G) Next Standard (1926 Subpart R App G)

Regulations (Standards - 29 CFR) - Table of Contents Regulations (Standards - 29 CFR) - Table of Contents



Back to Top Back to Top www.osha.gov www.dol.gov

Contact Us | Freedom of Information Act | Customer Survey
Privacy and Security Statement | Disclaimers
Occupational Safety & Health Administration
200 Constitution Avenue, NW
Washington, DC 20210