North Carolina DOE Status of State Energy Codes
Residential |
Commercial |
Statewide Residential Code:
State Specific Code |
Statewide Commercial Code:
State Specific Code |
State Amendments:
Yes |
State Amendments:
Yes |
Adoption by Local County/Jursidiction:
Mandatory |
Adoption by Local County/Jursidiction:
Mandatory |
Can use REScheck to show compliance:
Yes |
Can use COMcheck to show compliance:
Yes |
Notes on the State's Residential Code:
State-developed code, modeled on the 2003 IECC with amendments & Chapter 11 of 2003 IRC with amendments. Prescriptive statewide requirements of SHGC 0.40 & U-value of 0.4 or better, trade-off between building envelope and HVAC equipment not allowed. |
Notes on the State's Commercial Code:
State-developed code, modeled on the 2003 IECC with amendments including ASHRAE/IESNA 90.1-2004. |
Approximate Stringency:
As stringent as the 2003 IECC |
Approximate Stringency:
As stringent as the ASHRAE 04 |
Current Status Comments:
The NC Building Code Council has adopted the 2003 IECC with NC amendments effective June 1, 2007. The amendments include adoption of ASHRAE 90.1-2004. Chapter 11 of the 2003 IRC has also been adopted and includes NC amendments. The proposed effective date for the 2009 NC State Building Codes is January 1, 2009. Amendments can be viewed at the following link http://www.ncdoi.com/OSFM/Engineering/BCC/engineering_bcc_codes_2009_proposed.asp |
State Website(s):
North Carolina Department of Insurance: http://www.ncdoi.com
North Carolina Office of State Fire Marshall http://www.ncdoi.com/OSFM/
Southeast Energy Efficiency Alliance: http://www.seealliance.org.
Primary Technical Contact:
Billy Hinton, Jr., PE
Mechanical and Energy Code Consultant
North Carolina Department of Insurance
Engineering Division
322 Chapanoke Rd
Raleigh, NC 27603
PH: (919) 661-5880 x 239
FX: (919) 662-4414
Email: bhinton@ncdoi.net
State Agency/Office Head:
Chris Noles, PE, Deputy Commissioner
North Carolina Department of Insurance
PH: (919) 661-5880 x223
Email: cnoles@ncdoi.net
Other Contact(s):
Henry Webster, Chief Plumbing Engineer
North Carolina Department of Insurance
PH: (919) 661-5880 x238
Email: hwebster@ncdoi.net
Barry Gupton, PE, Chief Code Consultant
North Carolina Department of Insurance
PH: (919) 661-5880 x232
Email: bgupton@ncdoi.net
Starlette Brown
Energy Division
North Carolina Deparment of Administration
1830A Tillery Place
Raleigh, NC 27604
PH: (919) 733-1897
E-Mail: sbrown@ncmail.net
Russell Duncan
NC Department of Administration
PH: (919) 733-1901
EMAIL: russell.duncan@ncmail.com
Additional State Information (certification, adoption, compliance, enforcement, history, grants)