skip navigation links 
 
 Search Options 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page
Information Notices
2008
2007
2006
2005
2004
2003
2002
2001
2000
1999
1998
1997
1996
1995
1994
1993
1992
1991
1990
1989
1988
1987
1986
1985
1984
1983
1982
1981
1980
1979

Information Notices - 1987

File Name Date Description
in87010s1 05/15/1997 Potential for Water Hammer During Restart of Residual Heat Removal Pumps
in87061s1 05/31/1988 Failure of Westinghouse W-2-Type Circuit Breaker Cell Switches
in87044s1 03/28/1988 Thimble Tube Thinning in Westinghouse Reactors
in87067 12/31/1987 Lessons Learned from Regional Inspections of Licensee Actions in Response to IE Bulletin 80-11
in87066 12/31/1987 Inappropriate Application of Commercial-Grade Components
in87028s1 12/28/1987 Air Systems Problems at U.S. Light Water Reactors
in87065 12/23/1987 Plant Operations Beyond Analyzed Conditions
in87064 12/22/1987 Conviction for Falsification of Security Training Records
in87035s1 12/16/1987 Reactor Trip Breaker, Westinghouse Model DS-416, Failed to Open on Manual Initiation from the Control Room
in87063 12/09/1987 Inadequate Net Positive Suction Head in Low Pressure Safety Systems
in87062 12/08/1987 Mechanical Failure of Indicating-Type Fuses
in87061 12/07/1987 Failure of Westinghouse W-2-Type Circuit Breaker Cell Switches
in87060 12/04/1987 Depressurization of Reactor Coolant Systems in Pressurized-Water Reactors
in87059 11/17/1987 Potential RHR Pump Loss
in87058 11/16/1987 Continuous Communications Following Emergency Notifications
in87057 11/06/1987 Loss of Emergency Boration Capability Due to Nitrogen Gas Intrusion
in87056 11/04/1987 Improper Hydraulic Control Unit Installation at BWR Plants
in87055 10/29/1987 Portable Moisture/Density Gauges: Recent Incidents of Portable Gauges Being Stolen or Lost
in87054 10/23/1987 Emergency Response Exercises
in87053 10/20/1987 Auxiliary Feedwater Pump Trips Resulting from Low Suction Pressure
in87052 10/16/1987 Insulation Breakdown of Silicone Rubber-Insulated Single Conductor Cables During High Potential Testing
in87051 10/13/1987 Failure of Low Pressure Safety Injection Pump Due to Seal Problems
in87050 10/09/1987 Potential LOCA at High- and Low-Pressure Interfaces from Fire Damage
in87049 10/09/1987 Deficiencies in Outside Containment Flooding Protection
in87048 10/09/1987 Information Concerning the Use of Anaerobic Adhesive/Sealants
in87047 10/05/1987 Transportation of Radiography Devices
in87046 09/30/1987 Undetected Loss of Reactor Coolant
in87045 09/25/1987 Recent Safety-Related Violations of NRC Requirements by Industrial Radiography Licensees
in87044 09/16/1987 Thimble Tube Thinning in Westinghouse Reactors
in87043 09/08/1987 Gaps in Neutron-Absorbing Material in High-Density Spent Fuel Storage Racks
in87042 09/04/1987 Diesel Generator Fuse Contacts
in87041 08/31/1987 Failures of Certain Brown Boveri Electric Circuit Breakers
in87040 08/31/1987 Backseating Valves Routinely to Prevent Packing Leakage
in87039 08/21/1987 Control of Hot Particle Contamination at Nuclear Power Plants
in87038 08/17/1987 Inadequate or Inadvertent Blocking of Valve Movement
in87037 08/10/1987 Compliance with the General License Provisions of 10 CFR Part 31
in87036 08/04/1987 Significant Unexpected Erosion of Feedwater Lines
in87035 07/30/1987 Reactor Trip Breaker, Westing Failed to Open on Manual Initiation from the Control Room
in87034 07/24/1987 Single Failures in Auxiliary Feedwater Systems
in87033 07/24/1987 Applicability of 10 CFR Part 21 to Nonlicensees
in87032 07/10/1987 Deficiencies in the Testing of Nuclear-Grade Activated Charcoal
in87031 07/10/1987 Blocking, Bracing, and Securing of Radioactive Materials Packages in Transportation
in87030 07/02/1987 Cracking of Surge Ring Brackets in Large General Electric Company Electric Motors
in87029 06/26/1987 Recent Safety-Related Incidents at Large Irradiators
in87028 06/22/1987 Air Systems Problems at U.S. Light Water Reactors
in87027 06/10/1987 Iranian Official Implies Vague Threat to U.S. Resources
in87026 06/11/1987 Cracks in Stiffening Rings on 48-Inch-Diameter UF6 Cylinders
in87025 06/11/1987 Potentially Significant Problems Resulting from Human Error Involving Wrong Unit, Wrong Train, or Wrong Component Events
in87024 06/04/1987 Operational Experience Involving Losses of Electrical Inverters
in87023 05/27/1987 Loss of Decay Heat Removal During Low Reactor Coolant Level Operation
in87022 05/22/1987 Operator Licensing Requalification Examinations at Nonpower Reactors
in87021 05/11/1987 Shutdown Order Issued Because Licensed Operators Asleep While on Duty
in87020 04/20/1987 Hydrogen Leak in Auxiliary Building
in87019 04/09/1987 Perforation and Cracking of Rod Cluster Control Assemblies
in87018 04/08/1987 Unauthorized Service on Teletherapy Units by Nonlicensed Maintenance Personnel
in87017 04/07/1987 Response Time of Scram Instrument Volume Level Detectors
in87016 04/02/1987 Degradation of Static "O" Ring Pressure Switches
in87015 03/25/1987 Compliance with the Posting Requirements of Subsection 223B of the Atomic Energy Act of 1954, as Amended
in87014 03/23/1987 Actuation of Fire Suppression System Causing Inoperability of Safety-Related Ventilation Equipment
in87013 02/24/1987 Potential for High Radiation Fields Following Loss of Water from Fuel Pool
in87012 02/13/1987 Potential Problems with Metal Clad Circuit Breakers, General Electric Type AKF-2-25
in87011 02/13/1987 Enclosure of Vital Equipment within Designated Vital Areas
in87010 02/11/1987 Potential for Water Hammer During Restart of Residual Heat Removal Pumps
in87009 02/05/1987 Emergency Diesel Generator Room Cooling Design Deficiency
in87008 02/04/1987 Degraded Motor Leads in Limitorque DC Motor Operators
in87007 02/03/1987 Quality Control of Onsite Dewatering/Solidification Operations by Outside Contractors
in87006 01/30/1987 Loss of Suction to Low-Pressure Service Water System Pumps Resulting from Loss of Siphon
in87005 02/02/1987 Miswiring in a Westinghouse Rod Control System
in87004 01/16/1987 Diesel Generator Fails Test Because of Degraded Fuel
in87003 01/15/1987 Segregation of Hazardous and Low-Level Radioactive Wastes
in87002 01/13/1987 Inadequate Seismic Qualification of Diaphragm Valves by Mathematical Modeling and Analysis
in87001 01/06/1987 RHR Valve Misalignment Causes Degradation of ECCS in PWRs


Privacy Policy | Site Disclaimer
Monday, February 19, 2007