Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned scrams | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 2208.0 | 2209.0 | 2159.0 | 2184.0 | 2208.0 | 2209.0 | 1614.8 | 2184.0 |
Indicator value | 0.9 | 0.9 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Unplanned power changes | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 2208.0 | 2209.0 | 2159.0 | 2184.0 | 2208.0 | 2209.0 | 1614.8 | 2184.0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Unplanned Scrams with Complications | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (BWR) | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Safety System Functional Failures | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -1.50E-08 | -1.50E-08 | -1.50E-08 | -3.20E-09 | -3.50E-09 | -9.20E-09 | -9.10E-09 | -3.10E-09 |
URI (ΔCDF) | -1.00E-07 | -9.90E-08 | -9.50E-08 | -2.50E-08 | 8.60E-08 | 2.30E-07 | 2.30E-07 | 1.00E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.15E-07 | -1.14E-07 | -1.10E-07 | -2.82E-08 | 8.25E-08 | 2.21E-07 | 2.21E-07 | 9.69E-08 |
Licensee Comments:
2Q/08: Changed PRA Parameter(s). A new PRA model (2006C) was approved and implemented in the 1st Quarter of 2008. PRA coefficients were updated in CDE to reflect the new model, effective for the 2nd Quarter of 2008.
Mitigating Systems Performance Index, High Pressure Injection System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 1.00E-07 | 1.00E-07 | 9.80E-08 | 2.80E-08 | 3.80E-08 | 6.60E-08 | 7.00E-08 | 3.30E-08 |
URI (ΔCDF) | 4.90E-08 | 4.90E-08 | 5.30E-08 | 5.80E-08 | 7.70E-08 | 5.20E-08 | 5.00E-08 | 5.80E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 1.49E-07 | 1.49E-07 | 1.51E-07 | 8.60E-08 | 1.15E-07 | 1.18E-07 | 1.20E-07 | 9.10E-08 |
Licensee Comments:
2Q/08: Changed PRA Parameter(s). A new PRA model (2006C) was approved and implemented in the 1st Quarter of 2008. PRA coefficients were updated in CDE to reflect the new model, effective for the 2nd Quarter of 2008.
Mitigating Systems Performance Index, Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -9.70E-09 | -9.70E-09 | -9.70E-09 | -4.50E-09 | -5.20E-09 | -9.70E-09 | -9.70E-09 | -4.70E-09 |
URI (ΔCDF) | -1.90E-08 | -1.90E-08 | -1.60E-08 | -6.80E-09 | -8.30E-09 | -1.60E-08 | -1.60E-08 | -7.60E-09 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -2.87E-08 | -2.87E-08 | -2.57E-08 | -1.13E-08 | -1.35E-08 | -2.57E-08 | -2.57E-08 | -1.23E-08 |
Licensee Comments:
2Q/08: Changed PRA Parameter(s). A new PRA model (2006C) was approved and implemented in the 1st Quarter of 2008. PRA coefficients were updated in CDE to reflect the new model, effective for the 2nd Quarter of 2008.
Mitigating Systems Performance Index, Residual Heat Removal System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | -1.30E-07 | -1.30E-07 | -1.30E-07 | -2.60E-09 | -2.50E-09 | -1.30E-07 | -1.30E-07 | -5.70E-08 |
URI (ΔCDF) | -1.90E-07 | -1.90E-07 | -1.60E-07 | -4.20E-09 | -4.30E-09 | -1.80E-07 | -1.80E-07 | -8.30E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -3.20E-07 | -3.20E-07 | -2.90E-07 | -6.80E-09 | -6.80E-09 | -3.10E-07 | -3.10E-07 | -1.40E-07 |
Licensee Comments:
2Q/08: Changed PRA Parameter(s). A new PRA model (2006C) was approved and implemented in the 1st Quarter of 2008. PRA coefficients were updated in CDE to reflect the new model, effective for the 2nd Quarter of 2008.
Mitigating Systems Performance Index, Cooling Water Systems | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
UAI (ΔCDF) | 4.50E-08 | 4.50E-08 | 4.10E-08 | -3.50E-11 | -3.50E-11 | -1.70E-09 | -1.70E-09 | 5.70E-08 |
URI (ΔCDF) | -2.90E-07 | -2.80E-07 | -2.70E-07 | -2.30E-08 | -2.80E-08 | -2.80E-07 | -2.70E-07 | -1.10E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -2.45E-07 | -2.35E-07 | -2.29E-07 | -2.30E-08 | -2.80E-08 | -2.82E-07 | -2.72E-07 | -5.30E-08 |
Licensee Comments:
2Q/08: Changed PRA Parameter(s). A new PRA model (2006C) was approved and implemented in the 1st Quarter of 2008. PRA coefficients were updated in CDE to reflect the new model, effective for the 2nd Quarter of 2008.
2Q/06: An internal review identified a minor discrepancy in MSPI data submitted for April 2006. This discrepancy was corrected in the 2nd Quarter 2008 submittal, and did not result in a change in current or past indicator color. This occurrence has been entered into the plant's corrective action program.
Reactor Coolant System Activity | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum activity | 0.000362 | 0.000345 | 0.000343 | 0.000348 | 0.000365 | 0.000381 | 0.000396 | 0.000402 | 0.000517 | 0.000593 | 0.000744 | 0.000973 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.3 | 0.3 | 0.4 | 0.5 |
Reactor Coolant System Activity | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum activity | 0.000986 | 0.000958 | 0.000940 | 0.000769 | 0.000771 | 0.000574 | 0.000650 | 0.000605 | 0.000237 | 0.000270 | 0.000267 | 0.000260 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0.5 | 0.5 | 0.5 | 0.4 | 0.4 | 0.3 | 0.3 | 0.3 | 0.1 | 0.1 | 0.1 | 0.1 |
Licensee Comments: none
Reactor Coolant System Leakage | 7/06 | 8/06 | 9/06 | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 |
Maximum leakage | 3.600 | 3.600 | 3.900 | 4.200 | 3.800 | 4.100 | 3.900 | 4.120 | 4.400 | 4.500 | 4.500 | 4.700 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 14.4 | 14.4 | 15.6 | 16.8 | 15.2 | 16.4 | 15.6 | 16.5 | 17.6 | 18.0 | 18.0 | 18.8 |
Reactor Coolant System Leakage | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 |
Maximum leakage | 5.100 | 5.800 | 3.400 | 3.500 | 3.600 | 3.400 | 3.300 | 3.300 | 4.400 | 4.600 | 4.700 | 6.700 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 20.4 | 23.2 | 13.6 | 14.0 | 14.4 | 13.6 | 13.2 | 13.2 | 17.6 | 18.4 | 18.8 | 26.8 |
Licensee Comments: none
Drill/Exercise Performance | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful opportunities | 37.0 | 35.0 | 26.0 | 44.0 | 50.0 | 50.0 | 7.0 | 49.0 |
Total opportunities | 37.0 | 36.0 | 26.0 | 44.0 | 52.0 | 50.0 | 8.0 | 52.0 |
Indicator value | 97.9% | 98.7% | 98.8% | 98.8% | 98.4% | 98.7% | 98.3% | 97.7% |
Licensee Comments:
3Q/07: An internal audit identified that an opportunity had been counted in the August 2007 data that had not been properly evaluated. This decreased the number of total drill, exercise and event opportunities from 53 to 52. This error had no impact on the Performance Indicator color, and has been entered into the plant's corrective action program. A subsequent internal audit identified that an opportunity had been counted in the August 2007 data that should have been counted in the June 2007 data. This decreased the number of total drill, exercise and event opportunities in August 2007 from 52 to 36. This error had no impact on the Performance Indicator color, and has been entered into the plant's corrective action program.
2Q/07: An internal audit identified that an opportunity had been counted in the August 2007 data that should have been counted in the June 2007 data. This increased the number of total drill, exercise and event opportunities in June 2007 from 12 to 28. This error had no impact on the Performance Indicator color, and has been entered into the plant's corrective action program.
4Q/06: An internal audit identified that an opportunity had been counted in the October 2006 data that should have been counted in the September 2006 data. This decreased the number of total drill, exercise and event opportunities in October 2006 from 25 to 18. This error had no impact on the Performance Indicator color, and has been entered into the plant's corrective action program.
3Q/06: An internal audit identified that an opportunity had been counted in the October 2006 data that should have been counted in the September 2006 data. This increased the number of total drill, exercise and event opportunities in September 2006 from 0 to 7. This error had no impact on the Performance Indicator color, and has been entered into the plant's corrective action program.
ERO Drill Participation | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Participating Key personnel | 60.0 | 62.0 | 62.0 | 65.0 | 68.0 | 65.0 | 63.0 | 67.0 |
Total Key personnel | 60.0 | 66.0 | 62.0 | 65.0 | 68.0 | 65.0 | 63.0 | 67.0 |
Indicator value | 100.0% | 93.9% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% |
Licensee Comments: none
Alert & Notification System | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
Successful siren-tests | 3189 | 3131 | 3188 | 3188 | 3182 | 3191 | 3191 | 3196 |
Total sirens-tests | 3200 | 3150 | 3197 | 3200 | 3200 | 3200 | 3200 | 3200 |
Indicator value | 99.7% | 99.6% | 99.6% | 99.6% | 99.5% | 99.6% | 99.6% | 99.7% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 3Q/06 | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none