Common-Cause Failure Database and Analysis System: Event Data Collection, Classification, and Coding (NUREG/CR-6268, Rev. 1)On this page: Download complete document The following links on this page are to documents in Adobe Portable Document Format (PDF). See our Plugins, Viewers, and Other Tools page for more information. For successful viewing of PDF documents on our site please be sure to use the latest version of Adobe. Publication InformationManuscript Completed: August 2007 Prepared by Idaho National Laboratory Department of Materials and Nuclear Engineering A.D. Salomon, NRC Project Manager Prepared for AbstractThis report on the Common-Cause Failure Database and Analysis System presents an overview of common-cause failure (CCF) analysis methods for use in the U.S. commercial nuclear power industry. Idaho National Laboratory staff identify equipment failures that contribute to CCF events through searches of Licensee Event Reports, Nuclear Plant Reliability Data System failure reports, and Equipment Performance and Information Exchange failure reports. The staff then enter the event information into a personal computer-based data analysis system (CCF system). This report summarizes how data are gathered, evaluated, and coded into the CCF system, and describes the process for using the data to estimate probabilistic risk assessment common-cause failure parameters. |