Electrical Insulators in a Reactor Accident Environment (NUREG/CR-1682)

On this page:

Download complete document

The following links on this page are to documents in Adobe Portable Document Format (PDF). See our Plugins, Viewers, and Other Tools page for more information. For successful viewing of PDF documents on our site please be sure to use the latest version of Adobe.


Publication Information

Otmar M. Stuetzer

Date Published: January 1981

Sandia National Laboratories Albuquerque, New Mexico 87185

operated by Sandia Corporation

for the
U. S. Department of Energy

Prepared for
Plant Instrumentation, Control, and Power Systems Branch
Office of Water Reactor Safety Research
U. S. Nuclear Regulatory Commission
Washington, DC 20555
Under Interagency Agreement DOE 40-550-75
NRC FIN No. A-1051-0

Availability Notice


Abstract

Wire connections in a reactor containment generally are made by means of many hundreds of insulating blocks ("terminal blocks") which are protected by metal boxes. A broad investigation was conducted to determine what effect the heat, steam, and contamination resulting from a nuclear reactor accident would have on-these terminal blocks. A comprehensive experimental program was performed at temperatures, pressures, and time constants characteristic of the Three Mile Island accident. A model was developed which predicts, within an error factor of 2, the probability of an electrical breakdown for a wide range of temperatures, contamination, and protective measures. "Normally dirty" terminals in a tightly closed protective box with a 6 mm "weephole" in a 480 V circuit had about one chance in 100 of suffering complete breakdown at Three Mile Island.* If flow retarders or "breathers" narrowed the effective size of the weephole, breakdown was less likely by about a factor of 3. For a large scale steam breakout with a temperature of 170 ° C, however, the breakdown probability for an unprotected terminal would be about 30% at the same voltage.

Terminal blocks are probably the weakest links in a reactor's electrical system, and concern about their presence in safety-related circuits is fully justified. Some remedial measures and some improvements for future installations are proposed.