Home > Electronic Reading Room > Document Collections > ACRS > Schedules and Agendas > 1999
> Plant License Renewal Subcommittee Meeting
ADVISORY COMMITTEE ON REACTOR SAFEGUARDS
PLANT LICENSE RENEWAL SUBCOMMITTEE MEETING
OCONEE APPLICATION
JUNE 30, 1999
ROCKVILLE, MARYLAND
- PROPOSED SCHEDULE -
TOPIC PRESENTER TIME
I. Opening Remarks M. Bonaca, ACRS 8:30-8:35 a.m.
II. Staff Introduction C. Grimes, NRR 8:35-8:40 a.m.
III. Topical Report BAW-2251, "Reactor Vessel" Duke Staff 8:40-10:00 a.m.
A. Appendix B: BAW-2275, Low Upper-Shelf
Toughness
B. Appendix C: BAW-2274, Fracture Mechanics
C. Action Items
***BREAK*** 10:00-10:15 a.m.
IV. Topical Report BAW-2251 (Continued) Duke Staff 10:15-11:30 a.m.
V. Final Safety Evaluation Related to BAW-2251 NRC Staff 11:30-12:00 noon
***LUNCH*** 12:00-1:00 p.m.
VI. Status of License Renewal Activities NRC Staff 1:00-1:45 p.m.
A. License Renewal Issues
B. Standard Format of Applications
C. Standard Review Plan, Regulatory Guide,
and NEI 95-10
VII. Overview of SER Related to Oconee License NRC Staff 1:45-2:15 p.m.
Renewal
A. Background
B. Organization of SER
C. Scoping and Screening Process (IPA)
D. Aging Management Programs
E. Time Limiting Aging Analyzes
***BREAK*** 2:15-2:30 p.m.
VIII. Duke Energy Corporation Presentation Duke Staff 2:30-3:30 p.m.
A. Background
B. License Renewal Application Scoping and
Screening Process (IPA)
C. Aging Effects
D. Aging Management Programs
E. Time Limiting Aging Analyzes
IX. SER Chap. 2.0 - Structures and Components NRC Staff 3:30-3:55 p.m.
Subject to an Aging Management Review
X. SER Chap. 3.1 - Applicable Aging Effects for NRC Staff 3:55-4:10 p.m.
Mechanical Components
XI. SER Chap. 3.2 - Common Aging Management NRC Staff 4:10-4:30 p.m.
Programs
XII. Discussion M. Bonaca, ACRS 4:30-5:30 p.m.
XIII. Recess M. Bonaca, ACRS 5:30 p.m.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
ADVISORY COMMITTEE ON REACTOR SAFEGUARDS
PLANT LICENSE RENEWAL SUBCOMMITTEE MEETING
OCONEE APPLICATION
JULY 1, 1999
ROCKVILLE, MARYLAND
- PROPOSED SCHEDULE -
TOPIC PRESENTER TIME
I. Opening Remarks M. Bonaca, ACRS 8:30-8:35 a.m.
II. SER Chap. 3.3 - Containment Structures NRC Staff 8:35-9:00 a.m.
III. SER Chap. 3.4 - Reactor Coolant System NRC Staff 9:00-9:20 a.m.
IV. SER Chap. 3.5 - Engineered Safety Features NRC Staff 9:20-9:40 a.m.
Systems
V. SER Chap. 3.6 - Auxiliary Systems NRC Staff 9:40-10:00 a.m.
***BREAK*** 10:00-10:15 a.m.
VI. SER Chap. 3.7: Steam and Power Conversion NRC Staff 10:15-10:35 a.m.
Systems
VII. SER Chap. 3.8: Structures and Component NRC Staff 10:35-11:00 a.m.
Support
VIII. SER Chap. 3.9: Electrical Components NRC Staff 11:00-11:20 a.m.
IX. SER Chap. 4.0: Time-Limited Aging Analyses NRC Staff 11:20-11:40 a.m.
X. Subcommittee Discussion M. Bonaca, ACRS 11:40-12:00 noon
A. Presentations for the September 1-3, 1999
ACRS Full Committee Meeting
B. Topics for ACRS Interim Letter
***LUNCH*** 12:00-1:00 p.m.
XI. Options For Crediting Existing Programs NRC Staff 1:00-2:00 p.m.
XII. Crediting Existing Programs NEI 2:00-2:45 p.m.
***BREAK*** 2:45-3:00 a.m.
XIII.Subcommittee Discussion M. Bonaca, ACRS 3:00-4:00 p.m.
A. Presentations for the July 14, 1999
ACRS Full Committee Meeting
B. Topics for ACRS Letter
C. Additional Staff Presentations
D. Future Meetings
XIV. Adjourn M. Bonaca, ACRS 4:00 p.m.
NOTE: Presentation time should not exceed 50 percent of the total time allocated for
specific item. The remaining 50 percent of the time is reserved for discussion.
Number of copies of the presentation materials to be provided to the ACRS - 25.
CONTACT: N. Dudley NFD@NRC.GOV ACRS Senior Staff Engineer
|