skip navigation links 
 
 Search Options 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page

Seabrook 1

2Q/2008 Performance Indicators

Licensee's General Comments: none



Link to Notes

Unplanned Scrams per 7000 Critical Hrs 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Unplanned scrams 0 0 0 0 0 0 1.0 0
Critical hours 2138.3 1332.8 2159.0 2184.0 2208.0 2209.0 1914.0 1305.4
                 
Indicator value 0 0 0 0 0 0 0.8 0.9


Licensee Comments: none




Link to Notes

Unplanned Power Changes per 7000 Critical Hrs 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Unplanned power changes 1.0 0 1.0 0 0 0 1.0 1.0
Critical hours 2138.3 1332.8 2159.0 2184.0 2208.0 2209.0 1914.0 1305.4
                 
Indicator value 0.8 0.9 1.8 1.8 0.9 0.8 0.8 1.8

Licensee Comments: none






Link to Notes

Unplanned Scrams with Complications 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Scrams with complications   0 0 0 0 0 0 0
                 
                 
Indicator value         0.0 0.0 0.0 0.0

Licensee Comments: none






Link to Notes

Safety System Functional Failures (PWR) 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Safety System Functional Failures 0 0 0 0 0 0 0 0
                 
Indicator value 0 0 0 0 0 0 0 0

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Emergency AC Power System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -1.00E-07 -3.50E-08 -3.50E-08 -5.00E-08 -5.00E-08 -7.40E-08 -7.40E-08 -7.40E-08
URI (ΔCDF) 1.30E-06 1.00E-06 1.00E-06 4.70E-07 4.70E-07 6.60E-07 7.20E-07 1.20E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value 1.20E-06 9.65E-07 9.65E-07 4.20E-07 4.20E-07 5.86E-07 6.46E-07 4.60E-08

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, High Pressure Injection System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -1.80E-08 -1.80E-08 -1.20E-08 -9.10E-09 -1.20E-08 -6.20E-09 -1.90E-09 -4.20E-09
URI (ΔCDF) -2.60E-08 -8.10E-09 -8.10E-09 -8.20E-09 -8.10E-09 -8.90E-09 -9.00E-09 -8.80E-09
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -4.40E-08 -2.61E-08 -2.01E-08 -1.73E-08 -2.01E-08 -1.51E-08 -1.09E-08 -1.30E-08

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Heat Removal System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -1.60E-07 -4.00E-08 -3.90E-08 -5.30E-08 -5.90E-08 -8.40E-08 -8.80E-08 -8.80E-08
URI (ΔCDF) -3.30E-07 -1.30E-07 -1.30E-07 -1.20E-07 -1.20E-07 -1.30E-07 -1.30E-07 -1.30E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -4.90E-07 -1.70E-07 -1.69E-07 -1.73E-07 -1.79E-07 -2.14E-07 -2.18E-07 -2.18E-07

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Residual Heat Removal System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -5.00E-08 -1.40E-08 -1.40E-08 -1.40E-08 -1.40E-08 -1.50E-08 -1.10E-08 -1.10E-08
URI (ΔCDF) -1.60E-07 -4.00E-08 -4.00E-08 -4.00E-08 -4.00E-08 -4.40E-08 -4.60E-08 -4.70E-08
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -2.10E-07 -5.40E-08 -5.40E-08 -5.40E-08 -5.40E-08 -5.90E-08 -5.70E-08 -5.80E-08

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Cooling Water Systems 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -1.10E-11 -3.20E-14 -3.20E-14 -3.20E-14 -3.20E-14 7.10E-09 7.20E-09 7.20E-09
URI (ΔCDF) -2.20E-07 -1.30E-07 -1.30E-07 -1.30E-07 -1.30E-07 -1.10E-07 -1.00E-07 -1.00E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -2.20E-07 -1.30E-07 -1.30E-07 -1.30E-07 -1.30E-07 -1.03E-07 -9.28E-08 -9.28E-08

Licensee Comments: none






Link to Notes

Reactor Coolant System Activity 7/06 8/06 9/06 10/06 11/06 12/06 1/07 2/07 3/07 4/07 5/07 6/07
Maximum activity 0.000112 0.000104 0.000125 N/A 0.000042 0.000059 0.000058 0.000077 0.000070 0.000055 0.000084 0.000079
Technical specification limit 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
                         
Indicator value 0 0 0 N/A 0 0 0 0 0 0 0 0
Reactor Coolant System Activity 7/07 8/07 9/07 10/07 11/07 12/07 1/08 2/08 3/08 4/08 5/08 6/08
Maximum activity 0.000087 0.000084 0.000088 0.000079 0.000084 0.000100 0.000120 0.000102 0.000148 N/A 0.000055 0.000057
Technical specification limit 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
                         
Indicator value 0 0 0 0 0 0 0 0 0 N/A 0 0

Licensee Comments: none






Link to Notes

Reactor Coolant System Leakage 7/06 8/06 9/06 10/06 11/06 12/06 1/07 2/07 3/07 4/07 5/07 6/07
Maximum leakage 0.046 0.050 0.050 0.152 0.290 0.060 0.103 0.030 0.045 0.047 0.035 0.034
Technical specification limit 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0
                         
Indicator value 0.5 0.5 0.5 1.5 2.9 0.6 1.0 0.3 0.5 0.5 0.4 0.3
Reactor Coolant System Leakage 7/07 8/07 9/07 10/07 11/07 12/07 1/08 2/08 3/08 4/08 5/08 6/08
Maximum leakage 0.036 0.040 0.035 0.036 0.039 0.039 0.045 0.057 0.053 0 0.039 0.018
Technical specification limit 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0
                         
Indicator value 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.6 0.5 0 0.4 0.2

Licensee Comments: none






Link to Notes

Drill/Exercise Performance 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Successful opportunities 24.0 32.0 18.0 17.0 29.0 33.0 19.0 16.0
Total opportunities 25.0 32.0 18.0 17.0 29.0 33.0 19.0 16.0
                 
Indicator value 98.8% 99.2% 99.1% 99.1% 99.1% 99.0% 99.0% 99.5%

Licensee Comments: none






Link to Notes

ERO Drill Participation 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Participating Key personnel 84.0 81.0 77.0 75.0 89.0 83.0 82.0 81.0
Total Key personnel 84.0 81.0 78.0 76.0 89.0 83.0 82.0 81.0
                 
Indicator value 100.0% 100.0% 98.7% 98.7% 100.0% 100.0% 100.0% 100.0%

Licensee Comments: none






Link to Notes

Alert & Notification System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Successful siren-tests 838 725 847 724 845 724 845 725
Total sirens-tests 847 726 847 726 847 726 847 726
                 
Indicator value 99.7% 99.7% 99.7% 99.6% 99.8% 99.8% 99.7% 99.8%

Licensee Comments: none






Link to Notes

Occupational Exposure Control Effectiveness 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
High radiation area occurrences 0 0 0 0 0 0 0 1
Very high radiation area occurrences 0 0 0 0 0 0 0 0
Unintended exposure occurrences 0 0 0 0 0 0 0 0
Indicator value 0 0 0 0 0 0 0 1

Licensee Comments: none






Link to Notes

RETS/ODCM Radiological Effluent 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
RETS/ODCM occurrences 0 0 0 0 0 0 0 0
                 
Indicator value 0 0 0 0 0 0 0 0

Licensee Comments: none






Physical Protection information not publicly available.



 
 
 
 

Top of page    Action Matrix Summary |  Inspection Findings Summary |  PI Summary |  Reactor Oversight Process

Last Modified: August 4, 2008