Braidwood 1

2Q/2008 Performance Indicators

Licensee's General Comments: none



Link to Notes

Unplanned Scrams per 7000 Critical Hrs 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Unplanned scrams 0 0 0 1.0 0 0 0 0
Critical hours 2208.0 2209.0 2159.0 2155.4 2207.0 1618.3 2183.0 2184.0
                 
Indicator value 0 0 0 0.8 0.8 0.9 0.9 0


Licensee Comments: none




Link to Notes

Unplanned Power Changes per 7000 Critical Hrs 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Unplanned power changes 0 0 0 0 0 0 1.0 0
Critical hours 2208.0 2209.0 2159.0 2155.4 2207.0 1618.3 2183.0 2184.0
                 
Indicator value 0 0 0 0 0 0 0.9 0.9

Licensee Comments: none






Link to Notes

Unplanned Scrams with Complications 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Scrams with complications   0 0 0 0 0 0 0
                 
                 
Indicator value         0.0 0.0 0.0 0.0

Licensee Comments: none






Link to Notes

Safety System Functional Failures (PWR) 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Safety System Functional Failures 0 0 0 0 0 0 0 0
                 
Indicator value 0 0 0 0 0 0 0 0

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Emergency AC Power System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) 1.30E-08 2.30E-08 2.30E-08 3.60E-08 3.70E-08 2.10E-08 2.10E-08 9.10E-08
URI (ΔCDF) -2.60E-07 -2.90E-07 -3.10E-07 -5.60E-08 -4.60E-08 -1.60E-06 -1.60E-06 -1.30E-06
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -2.47E-07 -2.67E-07 -2.87E-07 -2.00E-08 -9.00E-09 -1.58E-06 -1.58E-06 -1.21E-06

Licensee Comments:

4Q/06: 3/31/07 - PRA parameters changed based on updates made to system unavailability data.

3Q/06: 3/31/07 - PRA parameters changed based on updates made to system unavailability data.






Link to Notes

Mitigating Systems Performance Index, High Pressure Injection System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -5.80E-08 -5.80E-08 -5.80E-08 -5.80E-08 -5.80E-08 -5.80E-08 -5.80E-08 -5.80E-08
URI (ΔCDF) -1.50E-08 -1.50E-08 -1.50E-08 -1.50E-08 -1.50E-08 -1.50E-08 -1.50E-08 -1.50E-08
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -7.30E-08 -7.30E-08 -7.30E-08 -7.30E-08 -7.30E-08 -7.30E-08 -7.30E-08 -7.30E-08

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Heat Removal System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -6.80E-07 -6.80E-07 -5.60E-07 -6.80E-07 -6.80E-07 -6.80E-07 -6.80E-07 -3.70E-07
URI (ΔCDF) -1.10E-06 -1.10E-06 -1.10E-06 -1.10E-06 -1.10E-06 -1.10E-06 -1.10E-06 4.90E-08
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -1.78E-06 -1.78E-06 -1.66E-06 -1.78E-06 -1.78E-06 -1.78E-06 -1.78E-06 -3.21E-07

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Residual Heat Removal System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -4.80E-08 -4.80E-08 -4.80E-08 -4.80E-08 -4.80E-08 5.40E-08 6.00E-08 6.20E-08
URI (ΔCDF) -1.40E-07 -1.40E-07 -1.40E-07 -1.40E-07 -1.40E-07 -1.30E-07 -1.30E-07 -1.40E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -1.88E-07 -1.88E-07 -1.88E-07 -1.88E-07 -1.88E-07 -7.60E-08 -7.00E-08 -7.80E-08

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Cooling Water Systems 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -5.80E-07 -5.90E-07 -4.60E-07 -6.20E-07 -6.40E-07 -7.90E-07 -7.80E-07 -3.20E-07
URI (ΔCDF) -4.20E-06 -4.20E-06 -4.10E-06 -4.10E-06 -4.10E-06 -4.10E-06 -4.10E-06 -3.90E-06
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -4.78E-06 -4.79E-06 -4.56E-06 -4.72E-06 -4.74E-06 -4.89E-06 -4.88E-06 -4.22E-06

Licensee Comments: none






Link to Notes

Reactor Coolant System Activity 7/06 8/06 9/06 10/06 11/06 12/06 1/07 2/07 3/07 4/07 5/07 6/07
Maximum activity 0.004950 0.005570 0.005334 0.005980 0.005330 0.005580 0.005752 0.006050 0.006310 0.006140 0.008630 0.007800
Technical specification limit 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
                         
Indicator value 0.5 0.6 0.5 0.6 0.5 0.6 0.6 0.6 0.6 0.6 0.9 0.8
Reactor Coolant System Activity 7/07 8/07 9/07 10/07 11/07 12/07 1/08 2/08 3/08 4/08 5/08 6/08
Maximum activity 0.008000 0.006690 0.007110 N/A 0.001320 0.001600 0.001460 0.001530 0.001590 0.001730 0.001780 0.001860
Technical specification limit 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
                         
Indicator value 0.8 0.7 0.7 N/A 0.1 0.2 0.1 0.2 0.2 0.2 0.2 0.2

Licensee Comments: none






Link to Notes

Reactor Coolant System Leakage 7/06 8/06 9/06 10/06 11/06 12/06 1/07 2/07 3/07 4/07 5/07 6/07
Maximum leakage 0.197 0.190 0.159 0.159 0.142 0.234 0.256 0.245 0.155 0.162 0.168 0.147
Technical specification limit 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0
                         
Indicator value 2.0 1.9 1.6 1.6 1.4 2.3 2.6 2.5 1.6 1.6 1.7 1.5
Reactor Coolant System Leakage 7/07 8/07 9/07 10/07 11/07 12/07 1/08 2/08 3/08 4/08 5/08 6/08
Maximum leakage 0.125 0.164 0.131 0.076 0.100 0.072 0.069 0.064 0.072 0.059 0.061 0.050
Technical specification limit 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0
                         
Indicator value 1.3 1.6 1.3 0.8 1.0 0.7 0.7 0.6 0.7 0.6 0.6 0.5

Licensee Comments: none






Link to Notes

Drill/Exercise Performance 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Successful opportunities 190.0 28.0 20.0 105.0 84.0 18.0 22.0 26.0
Total opportunities 194.0 28.0 20.0 106.0 84.0 19.0 24.0 26.0
                 
Indicator value 98.7% 98.7% 98.9% 99.0% 98.9% 98.7% 98.4% 98.4%

Licensee Comments: none






Link to Notes

ERO Drill Participation 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Participating Key personnel 74.0 76.0 74.0 72.0 73.0 75.0 71.0 69.0
Total Key personnel 74.0 76.0 74.0 76.0 75.0 75.0 71.0 69.0
                 
Indicator value 100.0% 100.0% 100.0% 94.7% 97.3% 100.0% 100.0% 100.0%

Licensee Comments: none






Link to Notes

Alert & Notification System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Successful siren-tests 4451 4400 4470 4466 4448 4474 4473 4465
Total sirens-tests 4480 4410 4480 4478 4480 4480 4478 4479
                 
Indicator value 99.7% 99.7% 99.7% 99.7% 99.6% 99.7% 99.7% 99.7%

Licensee Comments: none






Link to Notes

Occupational Exposure Control Effectiveness 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
High radiation area occurrences 0 0 0 0 0 0 0 0
Very high radiation area occurrences 0 0 0 0 0 0 0 0
Unintended exposure occurrences 0 0 0 0 0 0 0 0
Indicator value 0 0 0 0 0 0 0 0

Licensee Comments: none






Link to Notes

RETS/ODCM Radiological Effluent 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
RETS/ODCM occurrences 0 0 0 0 0 0 0 0
                 
Indicator value 0 0 0 0 0 0 0 0

Licensee Comments: none






Physical Protection information not publicly available.



 
 
 
 

Top of page    Action Matrix Summary |  Inspection Findings Summary |  PI Summary |  Reactor Oversight Process

Last Modified: August 4, 2008