Control of Heavy Loads at Nuclear Power Plants (NUREG-0612)On this page: Download complete document The following links on this page are to documents in Adobe Portable Document Format (PDF). See our Plugins, Viewers, and Other Tools page for more information. For successful viewing of PDF documents on our site please be sure to use the latest version of Adobe.
Publication InformationManuscript Completed: January 1980 h. George, Task Manager Office of Nuclear Reactor Regulation AbstractIn nuclear power plants heavy loads may be handled in several plant areas. If
these loads were to drop in certain locations in the plant, they may impact
spent fuel, fuel in the core, or equipment that may be required to achieve Task A-36 was established to systematically examine staff licensing criteria and the adequacy of measures in effect at operating plants, and to recommend necescary changes to assure the safe handling of heavy loads. The task involved review of licensee information, evaluation of historical data, performance of accident analyses and criticality calculations, development of guidelines for operating plants, and review of licensing criteria. This report provides the results of the NRC staff's review of the handling of heavy loads and includes the NRC staff's recommeniations on actions that should be taken to assure safe handling of heavy loads. These recommendations include: (1) a program should be initiated to review operating plants against the guidelines developed in Task A-36; (2) certain interim measures should be taken for operating plants until completion of this review program; (3) changes to certain Standard Review Plans and Regulatory Guides should be made to incorporate the guidelines in this report; (4) changes to technical specifications should be made after completion of the review; and (a task should be initated to establish guidelines for the control of small loads near spent fuel. The guidelines proposed include definition of safe load paths, use of load handling procedures, training of crane operators, guidelines on slings and special lifting devices, periodic inspection and maintenance for the crane, as well as various alternatives that include: use of a single failure proof handling system, use of mechanical stops or electrical interlocks to keep heavy loads away from fuel or safe shutdown equipment, or analyzing the consequences of postulated heavy load drops to show these are within acceptable limits. This report completes Task A-36. |
Privacy Policy |
Site Disclaimer |